Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction

Background: The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. Liners provide a comfortable interface by adding a soft cushion between the residual limb and the socket. The Dermo and the Seal-In X5 liner are...

Full description

Saved in:
Bibliographic Details
Main Authors: Ali, S., Abu Osman, Noor Azuan, Mortaza, N., Eshraghi, A., Gholizadeh, H., Wan Abas, Wan Abu Bakar
Format: Article
Language:English
Published: 2012
Subjects:
Online Access:http://eprints.um.edu.my/9486/1/Clinical_investigation_of_the_interface_pressure_in_the_trans-tibial_socket_with_Dermo_and_Seal-In_X5_liner_during_walking_and_their_effect_on_patient_satisfaction.pdf
http://eprints.um.edu.my/9486/
http://www.scopus.com/inward/record.url?eid=2-s2.0-84866409983&partnerID=40&md5=fe76fed5e8e48a949bc1613e56b4e982 http://www.sciencedirect.com/science/article/pii/S0268003312001295 http://www.ncbi.nlm.nih.gov/pubmed/22795863 http://ac.els-cdn.com/S02680033
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.9486
record_format eprints
spelling my.um.eprints.94862019-02-07T07:59:55Z http://eprints.um.edu.my/9486/ Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction Ali, S. Abu Osman, Noor Azuan Mortaza, N. Eshraghi, A. Gholizadeh, H. Wan Abas, Wan Abu Bakar T Technology (General) TA Engineering (General). Civil engineering (General) Background: The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. Liners provide a comfortable interface by adding a soft cushion between the residual limb and the socket. The Dermo and the Seal-In X5 liner are two new interface systems and, due to their relative infancy, very little are known about their effect on patient satisfaction. The aim of this study was to compare the interface pressure with these two liners and their effect on patient satisfaction. Methods: Nine unilateral transtibial amputees participated in the study. Two prostheses were fabricated for each amputee, one with the Seal-In liner and one with the Dermo liner. Interface pressure was measured at the anterior, posterior, medial and lateral regions during walking on the level ground. Each subject filled in a Prosthetic Evaluation Questionnaire (PEQ) regarding the satisfaction with the two liners. Findings The mean peak pressures with the Seal-In liner was 34.0 higher at the anterior, 24.0 higher at the posterior and 7.0 higher at the medial regions of the socket (P = 0.008, P = 0.046, P = 0.025) than it was with the Dermo Liner. There were no significant differences in the mean peak pressures between the two liners at the lateral regions. In addition, significant difference was found between the two liners both for satisfaction and problems (P < 0.05). Interpretation There was less interface pressure between the socket and the residual limb with the Dermo liner. The results indicated that the Dermo liner provides more comfort in the socket than the Seal-In liner. 2012 Article PeerReviewed application/pdf en http://eprints.um.edu.my/9486/1/Clinical_investigation_of_the_interface_pressure_in_the_trans-tibial_socket_with_Dermo_and_Seal-In_X5_liner_during_walking_and_their_effect_on_patient_satisfaction.pdf Ali, S. and Abu Osman, Noor Azuan and Mortaza, N. and Eshraghi, A. and Gholizadeh, H. and Wan Abas, Wan Abu Bakar (2012) Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction. Clinical Biomechanics, 27 (9). pp. 943-948. ISSN 0268-0033 http://www.scopus.com/inward/record.url?eid=2-s2.0-84866409983&partnerID=40&md5=fe76fed5e8e48a949bc1613e56b4e982 http://www.sciencedirect.com/science/article/pii/S0268003312001295 http://www.ncbi.nlm.nih.gov/pubmed/22795863 http://ac.els-cdn.com/S02680033 10.1016/j.clinbiomech.2012.06.004
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
language English
topic T Technology (General)
TA Engineering (General). Civil engineering (General)
spellingShingle T Technology (General)
TA Engineering (General). Civil engineering (General)
Ali, S.
Abu Osman, Noor Azuan
Mortaza, N.
Eshraghi, A.
Gholizadeh, H.
Wan Abas, Wan Abu Bakar
Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction
description Background: The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. Liners provide a comfortable interface by adding a soft cushion between the residual limb and the socket. The Dermo and the Seal-In X5 liner are two new interface systems and, due to their relative infancy, very little are known about their effect on patient satisfaction. The aim of this study was to compare the interface pressure with these two liners and their effect on patient satisfaction. Methods: Nine unilateral transtibial amputees participated in the study. Two prostheses were fabricated for each amputee, one with the Seal-In liner and one with the Dermo liner. Interface pressure was measured at the anterior, posterior, medial and lateral regions during walking on the level ground. Each subject filled in a Prosthetic Evaluation Questionnaire (PEQ) regarding the satisfaction with the two liners. Findings The mean peak pressures with the Seal-In liner was 34.0 higher at the anterior, 24.0 higher at the posterior and 7.0 higher at the medial regions of the socket (P = 0.008, P = 0.046, P = 0.025) than it was with the Dermo Liner. There were no significant differences in the mean peak pressures between the two liners at the lateral regions. In addition, significant difference was found between the two liners both for satisfaction and problems (P < 0.05). Interpretation There was less interface pressure between the socket and the residual limb with the Dermo liner. The results indicated that the Dermo liner provides more comfort in the socket than the Seal-In liner.
format Article
author Ali, S.
Abu Osman, Noor Azuan
Mortaza, N.
Eshraghi, A.
Gholizadeh, H.
Wan Abas, Wan Abu Bakar
author_facet Ali, S.
Abu Osman, Noor Azuan
Mortaza, N.
Eshraghi, A.
Gholizadeh, H.
Wan Abas, Wan Abu Bakar
author_sort Ali, S.
title Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction
title_short Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction
title_full Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction
title_fullStr Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction
title_full_unstemmed Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction
title_sort clinical investigation of the interface pressure in the trans-tibial socket with dermo and seal-in x5 liner during walking and their effect on patient satisfaction
publishDate 2012
url http://eprints.um.edu.my/9486/1/Clinical_investigation_of_the_interface_pressure_in_the_trans-tibial_socket_with_Dermo_and_Seal-In_X5_liner_during_walking_and_their_effect_on_patient_satisfaction.pdf
http://eprints.um.edu.my/9486/
http://www.scopus.com/inward/record.url?eid=2-s2.0-84866409983&partnerID=40&md5=fe76fed5e8e48a949bc1613e56b4e982 http://www.sciencedirect.com/science/article/pii/S0268003312001295 http://www.ncbi.nlm.nih.gov/pubmed/22795863 http://ac.els-cdn.com/S02680033
_version_ 1643688576483852288
score 13.211869