Analysis of arrester energy for 132kV overhead transmission line due to back flashover and shielding failure

This paper presents the analysis of lightning arrester energy due to back flashover and shielding failure phenomena in a 132kV transmission line in Malaysia. The transmission line, towers and surge arresters were modeled using PSCAD/EMTDC software. The model has been used to simulate the discharged...

Full description

Saved in:
Bibliographic Details
Main Authors: Hassan, Nor Hidayah Nor, Bakar, Ab Halim Abu, Mokhlis, Hazlie, Illias, Hazlee Azil
Format: Conference or Workshop Item
Language:English
Published: 2012
Subjects:
Online Access:http://eprints.um.edu.my/7851/1/Analysis_of_arrester_energy_for_132kV_overhead_transmission_line_due_to_back_flashover_and_shielding_failure.pdf
http://eprints.um.edu.my/7851/
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6450302
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.7851
record_format eprints
spelling my.um.eprints.78512019-12-06T08:32:07Z http://eprints.um.edu.my/7851/ Analysis of arrester energy for 132kV overhead transmission line due to back flashover and shielding failure Hassan, Nor Hidayah Nor Bakar, Ab Halim Abu Mokhlis, Hazlie Illias, Hazlee Azil TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering This paper presents the analysis of lightning arrester energy due to back flashover and shielding failure phenomena in a 132kV transmission line in Malaysia. The transmission line, towers and surge arresters were modeled using PSCAD/EMTDC software. The model has been used to simulate the discharged energy from lightning arresters that were installed on the tower in the event of back flashover and shielding failure. The arrester was modeled based on the IEEE frequency dependent model. Comparison between the simulation results and values calculated theoretically was performed to validate the model that has been developed. The results show that both are in reasonable agreement with each other. The maximum calculated and simulated energy discharged by the arrester is found to be less than 5.1 kJ/kV, which is the rating of arresters installed in the actual 132kV transmission lines. 2012 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.um.edu.my/7851/1/Analysis_of_arrester_energy_for_132kV_overhead_transmission_line_due_to_back_flashover_and_shielding_failure.pdf Hassan, Nor Hidayah Nor and Bakar, Ab Halim Abu and Mokhlis, Hazlie and Illias, Hazlee Azil (2012) Analysis of arrester energy for 132kV overhead transmission line due to back flashover and shielding failure. In: 2012 IEEE International Conference on Power and Energy, PECon 2012, 2012, Kota Kinabalu. http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6450302
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TA Engineering (General). Civil engineering (General)
TK Electrical engineering. Electronics Nuclear engineering
Hassan, Nor Hidayah Nor
Bakar, Ab Halim Abu
Mokhlis, Hazlie
Illias, Hazlee Azil
Analysis of arrester energy for 132kV overhead transmission line due to back flashover and shielding failure
description This paper presents the analysis of lightning arrester energy due to back flashover and shielding failure phenomena in a 132kV transmission line in Malaysia. The transmission line, towers and surge arresters were modeled using PSCAD/EMTDC software. The model has been used to simulate the discharged energy from lightning arresters that were installed on the tower in the event of back flashover and shielding failure. The arrester was modeled based on the IEEE frequency dependent model. Comparison between the simulation results and values calculated theoretically was performed to validate the model that has been developed. The results show that both are in reasonable agreement with each other. The maximum calculated and simulated energy discharged by the arrester is found to be less than 5.1 kJ/kV, which is the rating of arresters installed in the actual 132kV transmission lines.
format Conference or Workshop Item
author Hassan, Nor Hidayah Nor
Bakar, Ab Halim Abu
Mokhlis, Hazlie
Illias, Hazlee Azil
author_facet Hassan, Nor Hidayah Nor
Bakar, Ab Halim Abu
Mokhlis, Hazlie
Illias, Hazlee Azil
author_sort Hassan, Nor Hidayah Nor
title Analysis of arrester energy for 132kV overhead transmission line due to back flashover and shielding failure
title_short Analysis of arrester energy for 132kV overhead transmission line due to back flashover and shielding failure
title_full Analysis of arrester energy for 132kV overhead transmission line due to back flashover and shielding failure
title_fullStr Analysis of arrester energy for 132kV overhead transmission line due to back flashover and shielding failure
title_full_unstemmed Analysis of arrester energy for 132kV overhead transmission line due to back flashover and shielding failure
title_sort analysis of arrester energy for 132kv overhead transmission line due to back flashover and shielding failure
publishDate 2012
url http://eprints.um.edu.my/7851/1/Analysis_of_arrester_energy_for_132kV_overhead_transmission_line_due_to_back_flashover_and_shielding_failure.pdf
http://eprints.um.edu.my/7851/
http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6450302
_version_ 1654960628788363264
score 13.159267