Light-scattering and turbidimetric detection of silica colloids in size-exclusion chromatography
Silica colloids were separated by size-exclusion chromatography and monitored by fluorimetric and UV detection. In the former means of detection, silica colloids were visualized by light-scattering. The signal intensity based on the light scattering increased with increasing size of the silica collo...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
2008
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/7473/ http://www.scopus.com/inward/record.url?eid=2-s2.0-42449092801&partnerID=40&md5=7b4c0a67e4aa8b20890f66d9bd18e461 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.7473 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.74732014-12-16T06:54:10Z http://eprints.um.edu.my/7473/ Light-scattering and turbidimetric detection of silica colloids in size-exclusion chromatography Aspanut, Z. Takeuchi, T. Lim, L.W. Yamada, T. QC Physics Silica colloids were separated by size-exclusion chromatography and monitored by fluorimetric and UV detection. In the former means of detection, silica colloids were visualized by light-scattering. The signal intensity based on the light scattering increased with increasing size of the silica colloids. The maximum intensity was observed at excitation wavelengths around 270-290nm. In UV detection, silica colloids were visualized based on turbidimetry, and the signal intensity also increased with increasing size of the silica colloids and with decreasing detection wavelength. The signal intensities for both light-scattering and turbidimetric detection were a linear function of the concentration of the silica colloids. The detection limit at S/N=3 for 78-nm colloids was 0.06 ppm for light-scattering detection whereas the LOD was 2.3 ppm for UV detection. Effects of mobile phase conditions and flow rate on resolution and peak shape were examined. Use of phosphate buffer allowed the separation of silica colloids of different sizes in size-exclusion chromatography. 2008 Article PeerReviewed Aspanut, Z. and Takeuchi, T. and Lim, L.W. and Yamada, T. (2008) Light-scattering and turbidimetric detection of silica colloids in size-exclusion chromatography. Analytical and Bioanalytical Chemistry, 391 (1). pp. 353-359. ISSN 1618-2642 http://www.scopus.com/inward/record.url?eid=2-s2.0-42449092801&partnerID=40&md5=7b4c0a67e4aa8b20890f66d9bd18e461 10.1007/s00216-008-2017-9 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
QC Physics |
spellingShingle |
QC Physics Aspanut, Z. Takeuchi, T. Lim, L.W. Yamada, T. Light-scattering and turbidimetric detection of silica colloids in size-exclusion chromatography |
description |
Silica colloids were separated by size-exclusion chromatography and monitored by fluorimetric and UV detection. In the former means of detection, silica colloids were visualized by light-scattering. The signal intensity based on the light scattering increased with increasing size of the silica colloids. The maximum intensity was observed at excitation wavelengths around 270-290nm. In UV detection, silica colloids were visualized based on turbidimetry, and the signal intensity also increased with increasing size of the silica colloids and with decreasing detection wavelength. The signal intensities for both light-scattering and turbidimetric detection were a linear function of the concentration of the silica colloids. The detection limit at S/N=3 for 78-nm colloids was 0.06 ppm for light-scattering detection whereas the LOD was 2.3 ppm for UV detection. Effects of mobile phase conditions and flow rate on resolution and peak shape were examined. Use of phosphate buffer allowed the separation of silica colloids of different sizes in size-exclusion chromatography. |
format |
Article |
author |
Aspanut, Z. Takeuchi, T. Lim, L.W. Yamada, T. |
author_facet |
Aspanut, Z. Takeuchi, T. Lim, L.W. Yamada, T. |
author_sort |
Aspanut, Z. |
title |
Light-scattering and turbidimetric detection of silica colloids in size-exclusion chromatography |
title_short |
Light-scattering and turbidimetric detection of silica colloids in size-exclusion chromatography |
title_full |
Light-scattering and turbidimetric detection of silica colloids in size-exclusion chromatography |
title_fullStr |
Light-scattering and turbidimetric detection of silica colloids in size-exclusion chromatography |
title_full_unstemmed |
Light-scattering and turbidimetric detection of silica colloids in size-exclusion chromatography |
title_sort |
light-scattering and turbidimetric detection of silica colloids in size-exclusion chromatography |
publishDate |
2008 |
url |
http://eprints.um.edu.my/7473/ http://www.scopus.com/inward/record.url?eid=2-s2.0-42449092801&partnerID=40&md5=7b4c0a67e4aa8b20890f66d9bd18e461 |
_version_ |
1643688050204606464 |
score |
13.18916 |