Performance study of water-to-water heat pump using non-azeotropic refrigerant mixtures R407C

This paper compares the performance of the refrigerant R22 and the non-ozone depleting R407C for high temperature heat pump heat recovery application. While most reported works were conducted on residential heat pumps with evaporating temperature below zero degree Celsius, this study considers highe...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdesselam, H., Masjuki, Haji Hassan, Saidur, Rahman, Sattar, M.A., Guellal, M.
Format: Article
Language:English
Published: 2008
Subjects:
Online Access:http://eprints.um.edu.my/6865/1/Performance_study_of_water-to-water_heat_pump_using_non-Azeotropic_refrigerant_mixtures_R407C.pdf
http://eprints.um.edu.my/6865/
http://ebookbrowse.com/gdoc.php?id=79268442&url=6fe7ed4a52311bc94ed74a640fa48ee2
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.6865
record_format eprints
spelling my.um.eprints.68652018-10-18T05:03:18Z http://eprints.um.edu.my/6865/ Performance study of water-to-water heat pump using non-azeotropic refrigerant mixtures R407C Abdesselam, H. Masjuki, Haji Hassan Saidur, Rahman Sattar, M.A. Guellal, M. TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery This paper compares the performance of the refrigerant R22 and the non-ozone depleting R407C for high temperature heat pump heat recovery application. While most reported works were conducted on residential heat pumps with evaporating temperature below zero degree Celsius, this study considers higher evaporating temperatures, from 5 to 35 degrees Celsius. The comparison was made by theoretical cycle calculation with variable heating and cooling capacities and at different temperatures. The experimental results of R407C were compared with the existing R22 refrigerant to explore the potential for retrofitting existing installations. It has been found that both the thermodynamic properties and general performance of R407C are comparable with that of R22. The operational behavior of R407C was found better with the increasing condensation and evaporation temperature. It has also been observed that the heating capacity of the refrigerant R407C is 5 higher than that of R22. When the compression ratio exceeds 3, at high evaporating temperatures, the coefficient of performance with R407C is greater than that obtained with R22. Therefore, R407C is a good substitute for R22 in all applications requiring high evaporation temperatures, such as air-conditioning plants and heat pumps for heat recovery. 2008 Article PeerReviewed application/pdf en http://eprints.um.edu.my/6865/1/Performance_study_of_water-to-water_heat_pump_using_non-Azeotropic_refrigerant_mixtures_R407C.pdf Abdesselam, H. and Masjuki, Haji Hassan and Saidur, Rahman and Sattar, M.A. and Guellal, M. (2008) Performance study of water-to-water heat pump using non-azeotropic refrigerant mixtures R407C. International Energy Journal, 9 (4). http://ebookbrowse.com/gdoc.php?id=79268442&url=6fe7ed4a52311bc94ed74a640fa48ee2
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
spellingShingle TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
Abdesselam, H.
Masjuki, Haji Hassan
Saidur, Rahman
Sattar, M.A.
Guellal, M.
Performance study of water-to-water heat pump using non-azeotropic refrigerant mixtures R407C
description This paper compares the performance of the refrigerant R22 and the non-ozone depleting R407C for high temperature heat pump heat recovery application. While most reported works were conducted on residential heat pumps with evaporating temperature below zero degree Celsius, this study considers higher evaporating temperatures, from 5 to 35 degrees Celsius. The comparison was made by theoretical cycle calculation with variable heating and cooling capacities and at different temperatures. The experimental results of R407C were compared with the existing R22 refrigerant to explore the potential for retrofitting existing installations. It has been found that both the thermodynamic properties and general performance of R407C are comparable with that of R22. The operational behavior of R407C was found better with the increasing condensation and evaporation temperature. It has also been observed that the heating capacity of the refrigerant R407C is 5 higher than that of R22. When the compression ratio exceeds 3, at high evaporating temperatures, the coefficient of performance with R407C is greater than that obtained with R22. Therefore, R407C is a good substitute for R22 in all applications requiring high evaporation temperatures, such as air-conditioning plants and heat pumps for heat recovery.
format Article
author Abdesselam, H.
Masjuki, Haji Hassan
Saidur, Rahman
Sattar, M.A.
Guellal, M.
author_facet Abdesselam, H.
Masjuki, Haji Hassan
Saidur, Rahman
Sattar, M.A.
Guellal, M.
author_sort Abdesselam, H.
title Performance study of water-to-water heat pump using non-azeotropic refrigerant mixtures R407C
title_short Performance study of water-to-water heat pump using non-azeotropic refrigerant mixtures R407C
title_full Performance study of water-to-water heat pump using non-azeotropic refrigerant mixtures R407C
title_fullStr Performance study of water-to-water heat pump using non-azeotropic refrigerant mixtures R407C
title_full_unstemmed Performance study of water-to-water heat pump using non-azeotropic refrigerant mixtures R407C
title_sort performance study of water-to-water heat pump using non-azeotropic refrigerant mixtures r407c
publishDate 2008
url http://eprints.um.edu.my/6865/1/Performance_study_of_water-to-water_heat_pump_using_non-Azeotropic_refrigerant_mixtures_R407C.pdf
http://eprints.um.edu.my/6865/
http://ebookbrowse.com/gdoc.php?id=79268442&url=6fe7ed4a52311bc94ed74a640fa48ee2
_version_ 1643687903107219456
score 13.159267