Effect of selected shading devices on office room temperature
This study investigated the effects of selected shading devices on office room temperature. The experimental results were presented to show the thermal effects of coating systems used. Initial work for a duration of two months showed that high temperatures occurred during 10:00, 12:00 and 14:00 hour...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
International Journal of Mechanical and Materials Engineering
2010
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/6726/ http://www.scopus.com/inward/record.url?eid=2-s2.0-78651414304&partnerID=40&md5=916a9aa3f6f60f873fcec3e194da3e53 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.6726 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.67262019-10-25T06:11:51Z http://eprints.um.edu.my/6726/ Effect of selected shading devices on office room temperature Whaad, A.M. Adam, N.M. Sapuan, S.M. Saidur, Rahman TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery This study investigated the effects of selected shading devices on office room temperature. The experimental results were presented to show the thermal effects of coating systems used. Initial work for a duration of two months showed that high temperatures occurred during 10:00, 12:00 and 14:00 hours. The coating materials used, were plain glass pane with the thickness of 5 mm (control), tinted film, silver film, and blinds. Results showed that the differences in temperatures between the inside and outside of the office were 4.4°C, 3.8°C, 3.5°C and 2.9°C for silver film, blinds, tinted film and clear glass (5 mm), respectively. In terms of cost, the blinds proved to be low in cost with every temperature drop for temperature difference between internal and external temperatures. For every degree difference, silver coating would cost RM 6.80/°C, tinted laminating RM4.57/°C, blind RM 1.97/°C, and clean glass (5mm) RM 1.90/ °C . RM is Malaysian Ringgit and 1Euro= 4.50 RM. In addition the blinds could be easily fixed comparatively. International Journal of Mechanical and Materials Engineering 2010 Article PeerReviewed Whaad, A.M. and Adam, N.M. and Sapuan, S.M. and Saidur, Rahman (2010) Effect of selected shading devices on office room temperature. International Journal of Mechanical and Materials Engineering, 5 (2). pp. 236-243. ISSN 18230334 http://www.scopus.com/inward/record.url?eid=2-s2.0-78651414304&partnerID=40&md5=916a9aa3f6f60f873fcec3e194da3e53 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery |
spellingShingle |
TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery Whaad, A.M. Adam, N.M. Sapuan, S.M. Saidur, Rahman Effect of selected shading devices on office room temperature |
description |
This study investigated the effects of selected shading devices on office room temperature. The experimental results were presented to show the thermal effects of coating systems used. Initial work for a duration of two months showed that high temperatures occurred during 10:00, 12:00 and 14:00 hours. The coating materials used, were plain glass pane with the thickness of 5 mm (control), tinted film, silver film, and blinds. Results showed that the differences in temperatures between the inside and outside of the office were 4.4°C, 3.8°C, 3.5°C and 2.9°C for silver film, blinds, tinted film and clear glass (5 mm), respectively. In terms of cost, the blinds proved to be low in cost with every temperature drop for temperature difference between internal and external temperatures. For every degree difference, silver coating would cost RM 6.80/°C, tinted laminating RM4.57/°C, blind RM 1.97/°C, and clean glass (5mm) RM 1.90/ °C . RM is Malaysian Ringgit and 1Euro= 4.50 RM. In addition the blinds could be easily fixed comparatively. |
format |
Article |
author |
Whaad, A.M. Adam, N.M. Sapuan, S.M. Saidur, Rahman |
author_facet |
Whaad, A.M. Adam, N.M. Sapuan, S.M. Saidur, Rahman |
author_sort |
Whaad, A.M. |
title |
Effect of selected shading devices on office room temperature |
title_short |
Effect of selected shading devices on office room temperature |
title_full |
Effect of selected shading devices on office room temperature |
title_fullStr |
Effect of selected shading devices on office room temperature |
title_full_unstemmed |
Effect of selected shading devices on office room temperature |
title_sort |
effect of selected shading devices on office room temperature |
publisher |
International Journal of Mechanical and Materials Engineering |
publishDate |
2010 |
url |
http://eprints.um.edu.my/6726/ http://www.scopus.com/inward/record.url?eid=2-s2.0-78651414304&partnerID=40&md5=916a9aa3f6f60f873fcec3e194da3e53 |
_version_ |
1648736063308431360 |
score |
13.160551 |