Tempered glass as a thermoluminescent medium for retrospective dosimetry
Globally, the use of nuclear facilities and the potential risks associated with the dispersal of ionizing radiation due to natural disasters or technical failures are on the rise. These risks can have severe consequences for the environment and all living organisms, particularly humans. There is cur...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Published: |
Elsevier
2024
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/45770/ https://doi.org/10.1016/j.radphyschem.2024.111534 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.45770 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.457702024-11-12T01:09:38Z http://eprints.um.edu.my/45770/ Tempered glass as a thermoluminescent medium for retrospective dosimetry Muslima, Umme Khandaker, Mayeen Uddin Lam, S. E. Nawi, S. N. Mat Sani, S. F. Abdul Osman, Hamid Hanfi, Mohamed Y. Sayyed, M. I. Bradley, D. A. QC Physics Globally, the use of nuclear facilities and the potential risks associated with the dispersal of ionizing radiation due to natural disasters or technical failures are on the rise. These risks can have severe consequences for the environment and all living organisms, particularly humans. There is currently no practical method available to accurately estimate the radiation doses received by the surrounding areas and individuals in such situations. To address this issue, retrospective dosimetry can be employed to estimate the actual radiation dose, followed by the implementation of remediation techniques. Considering this need, tempered glass, which is commonly used as a screen protector for smartphones by the general public, has been identified as a promising medium for retrospective dosimetry. The present study aimed to investigate the thermoluminescence (TL) properties of six different types of tempered glass subjected to Co-60 gamma rays, specifically examining the TL dose response, linearity, repeatability, and fading. Among the various glass samples tested, HD anti-peep tempered glass demonstrates a highly linear dose-response and the greatest dose sensitivity within the examined dose range of 2-50 Gy. Additionally, the HD anti-peep tempered glass exhibits minimal loss of TL yield (similar to 23%) at 28 days post-irradiation, making it particularly suitable for use as a retrospective dosimeter. Elsevier 2024-04 Article PeerReviewed Muslima, Umme and Khandaker, Mayeen Uddin and Lam, S. E. and Nawi, S. N. Mat and Sani, S. F. Abdul and Osman, Hamid and Hanfi, Mohamed Y. and Sayyed, M. I. and Bradley, D. A. (2024) Tempered glass as a thermoluminescent medium for retrospective dosimetry. Radiation Physics and Chemistry, 217. p. 111534. ISSN 0969-806X, DOI https://doi.org/10.1016/j.radphyschem.2024.111534 <https://doi.org/10.1016/j.radphyschem.2024.111534>. https://doi.org/10.1016/j.radphyschem.2024.111534 10.1016/j.radphyschem.2024.111534 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
QC Physics |
spellingShingle |
QC Physics Muslima, Umme Khandaker, Mayeen Uddin Lam, S. E. Nawi, S. N. Mat Sani, S. F. Abdul Osman, Hamid Hanfi, Mohamed Y. Sayyed, M. I. Bradley, D. A. Tempered glass as a thermoluminescent medium for retrospective dosimetry |
description |
Globally, the use of nuclear facilities and the potential risks associated with the dispersal of ionizing radiation due to natural disasters or technical failures are on the rise. These risks can have severe consequences for the environment and all living organisms, particularly humans. There is currently no practical method available to accurately estimate the radiation doses received by the surrounding areas and individuals in such situations. To address this issue, retrospective dosimetry can be employed to estimate the actual radiation dose, followed by the implementation of remediation techniques. Considering this need, tempered glass, which is commonly used as a screen protector for smartphones by the general public, has been identified as a promising medium for retrospective dosimetry. The present study aimed to investigate the thermoluminescence (TL) properties of six different types of tempered glass subjected to Co-60 gamma rays, specifically examining the TL dose response, linearity, repeatability, and fading. Among the various glass samples tested, HD anti-peep tempered glass demonstrates a highly linear dose-response and the greatest dose sensitivity within the examined dose range of 2-50 Gy. Additionally, the HD anti-peep tempered glass exhibits minimal loss of TL yield (similar to 23%) at 28 days post-irradiation, making it particularly suitable for use as a retrospective dosimeter. |
format |
Article |
author |
Muslima, Umme Khandaker, Mayeen Uddin Lam, S. E. Nawi, S. N. Mat Sani, S. F. Abdul Osman, Hamid Hanfi, Mohamed Y. Sayyed, M. I. Bradley, D. A. |
author_facet |
Muslima, Umme Khandaker, Mayeen Uddin Lam, S. E. Nawi, S. N. Mat Sani, S. F. Abdul Osman, Hamid Hanfi, Mohamed Y. Sayyed, M. I. Bradley, D. A. |
author_sort |
Muslima, Umme |
title |
Tempered glass as a thermoluminescent medium for retrospective dosimetry |
title_short |
Tempered glass as a thermoluminescent medium for retrospective dosimetry |
title_full |
Tempered glass as a thermoluminescent medium for retrospective dosimetry |
title_fullStr |
Tempered glass as a thermoluminescent medium for retrospective dosimetry |
title_full_unstemmed |
Tempered glass as a thermoluminescent medium for retrospective dosimetry |
title_sort |
tempered glass as a thermoluminescent medium for retrospective dosimetry |
publisher |
Elsevier |
publishDate |
2024 |
url |
http://eprints.um.edu.my/45770/ https://doi.org/10.1016/j.radphyschem.2024.111534 |
_version_ |
1816130456939134976 |
score |
13.214268 |