An innovative survey poles configuration: an alternative 3-D volume calibrating system
The purpose of this study is to develop an alternative method for calibrating a threedimensional volume. The new calibration frame uses a set of four poles, consisting of 20 control points. An experiment was conducted to compare the result obtained using two methods of calibration, the Peak calibrat...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2003
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/4442/1/An_innovative_survey_poles_configuration_An_alternative_3-D_volume_calibrating_system.pdf http://eprints.um.edu.my/4442/ http://www.google.com.my/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&ved=0CCQQFjAA&url=http%3A%2F%2Fwww.jurnalteknologi.utm.my%2Findex.php%2Fjurnalteknologi%2Farticle%2Fdownload%2F482%2F472&ei=7B6TULuIO4aTiAf2nIGICA&usg=AFQjCNG_CT9t-EIaKqRrbKjfNO5sCC |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.4442 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.44422019-02-07T08:32:31Z http://eprints.um.edu.my/4442/ An innovative survey poles configuration: an alternative 3-D volume calibrating system Rambely, A.S. Abu Osman, Noor Azuan Wan Abas, Wan Abu Bakar Usman, J. Yusof, M.S. TA Engineering (General). Civil engineering (General) The purpose of this study is to develop an alternative method for calibrating a threedimensional volume. The new calibration frame uses a set of four poles, consisting of 20 control points. An experiment was conducted to compare the result obtained using two methods of calibration, the Peak calibration frame (the control) and the ISN-UM survey poles system (the new reference frame). It was found that the results obtained from the ISN-UM calibration frame are comparable to those obtained using the Peak calibration frame, despite the differences in the locations and the numbers of control points, as well as the physical characteristics of both structures. 2003 Article PeerReviewed application/pdf en http://eprints.um.edu.my/4442/1/An_innovative_survey_poles_configuration_An_alternative_3-D_volume_calibrating_system.pdf Rambely, A.S. and Abu Osman, Noor Azuan and Wan Abas, Wan Abu Bakar and Usman, J. and Yusof, M.S. (2003) An innovative survey poles configuration: an alternative 3-D volume calibrating system. Jurnal Teknologi. http://www.google.com.my/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&ved=0CCQQFjAA&url=http%3A%2F%2Fwww.jurnalteknologi.utm.my%2Findex.php%2Fjurnalteknologi%2Farticle%2Fdownload%2F482%2F472&ei=7B6TULuIO4aTiAf2nIGICA&usg=AFQjCNG_CT9t-EIaKqRrbKjfNO5sCC |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Rambely, A.S. Abu Osman, Noor Azuan Wan Abas, Wan Abu Bakar Usman, J. Yusof, M.S. An innovative survey poles configuration: an alternative 3-D volume calibrating system |
description |
The purpose of this study is to develop an alternative method for calibrating a threedimensional volume. The new calibration frame uses a set of four poles, consisting of 20 control points. An experiment was conducted to compare the result obtained using two methods of calibration, the Peak calibration frame (the control) and the ISN-UM survey poles system (the new reference frame). It was found that the results obtained from the ISN-UM calibration frame are comparable to those obtained using the Peak calibration frame, despite the differences in the locations and the numbers of control points, as well as the physical characteristics of both structures. |
format |
Article |
author |
Rambely, A.S. Abu Osman, Noor Azuan Wan Abas, Wan Abu Bakar Usman, J. Yusof, M.S. |
author_facet |
Rambely, A.S. Abu Osman, Noor Azuan Wan Abas, Wan Abu Bakar Usman, J. Yusof, M.S. |
author_sort |
Rambely, A.S. |
title |
An innovative survey poles configuration: an alternative 3-D volume calibrating system |
title_short |
An innovative survey poles configuration: an alternative 3-D volume calibrating system |
title_full |
An innovative survey poles configuration: an alternative 3-D volume calibrating system |
title_fullStr |
An innovative survey poles configuration: an alternative 3-D volume calibrating system |
title_full_unstemmed |
An innovative survey poles configuration: an alternative 3-D volume calibrating system |
title_sort |
innovative survey poles configuration: an alternative 3-d volume calibrating system |
publishDate |
2003 |
url |
http://eprints.um.edu.my/4442/1/An_innovative_survey_poles_configuration_An_alternative_3-D_volume_calibrating_system.pdf http://eprints.um.edu.my/4442/ http://www.google.com.my/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&ved=0CCQQFjAA&url=http%3A%2F%2Fwww.jurnalteknologi.utm.my%2Findex.php%2Fjurnalteknologi%2Farticle%2Fdownload%2F482%2F472&ei=7B6TULuIO4aTiAf2nIGICA&usg=AFQjCNG_CT9t-EIaKqRrbKjfNO5sCC |
_version_ |
1643687335391395840 |
score |
13.211869 |