Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia

This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category...

Full description

Saved in:
Bibliographic Details
Main Authors: Hambali, A.S., Ng, K.H., Abdullah, B.J.J., Wang, H.B., Jamal, N., Spelic, D.C., Suleiman, O.H.
Format: Article
Language:English
Published: Oxford University Press 2009
Subjects:
Online Access:http://eprints.um.edu.my/4138/1/Entrance_surface_dose_and_image_quality_comparison_of_adult_chest_and_abdominal_X-ray_examinations_in_general_practitioner_clinics%2C_public_and_private_hospitals_in_Malaysia.pdf
http://eprints.um.edu.my/4138/
https://doi.org/10.1093/rpd/ncp007
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.4138
record_format eprints
spelling my.um.eprints.41382019-03-18T08:36:12Z http://eprints.um.edu.my/4138/ Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia Hambali, A.S. Ng, K.H. Abdullah, B.J.J. Wang, H.B. Jamal, N. Spelic, D.C. Suleiman, O.H. R Medicine This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category (28 GP clinics, 20 public hospitals and 15 private hospitals). Only departmental X-ray units were involved in the survey. Chest examinations were done at all facilities, while only hospitals performed abdominal examinations. This study used the x-ray attenuation phantoms and protocols developed for the Nationwide Evaluation of X-ray Trends (NEXT) survey program in the United States. The ESD was calculated from measurements of exposure and clinical geometry. An image quality test tool was used to evaluate the low-contrast detectability and high-contrast detail performance under typical clinical conditions. The median ESD value for the adult chest X-ray examination was the highest (0.25 mGy) at GP clinics, followed by private hospitals (0.22 mGy) and public hospitals (0.17 mGy). The median ESD for the adult abdominal X-ray examination at public hospitals (3.35 mGy) was higher than that for private hospitals (2.81 mGy). Results of image quality assessment for the chest X-ray examination show that all facility types have a similar median spatial resolution and low-contrast detectability. For the abdominal X-ray examination, public hospitals have a similar median spatial resolution but larger low-contrast detectability compared with private hospitals. The results of this survey clearly show that there is room for further improvement in performing chest and abdominal X-ray examinations in Malaysia. Oxford University Press 2009 Article PeerReviewed application/pdf en http://eprints.um.edu.my/4138/1/Entrance_surface_dose_and_image_quality_comparison_of_adult_chest_and_abdominal_X-ray_examinations_in_general_practitioner_clinics%2C_public_and_private_hospitals_in_Malaysia.pdf Hambali, A.S. and Ng, K.H. and Abdullah, B.J.J. and Wang, H.B. and Jamal, N. and Spelic, D.C. and Suleiman, O.H. (2009) Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia. Radiation Protection Dosimetry, 133 (1). pp. 25-34. ISSN 0144-8420 https://doi.org/10.1093/rpd/ncp007 10.1093/rpd/ncp007
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
language English
topic R Medicine
spellingShingle R Medicine
Hambali, A.S.
Ng, K.H.
Abdullah, B.J.J.
Wang, H.B.
Jamal, N.
Spelic, D.C.
Suleiman, O.H.
Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia
description This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category (28 GP clinics, 20 public hospitals and 15 private hospitals). Only departmental X-ray units were involved in the survey. Chest examinations were done at all facilities, while only hospitals performed abdominal examinations. This study used the x-ray attenuation phantoms and protocols developed for the Nationwide Evaluation of X-ray Trends (NEXT) survey program in the United States. The ESD was calculated from measurements of exposure and clinical geometry. An image quality test tool was used to evaluate the low-contrast detectability and high-contrast detail performance under typical clinical conditions. The median ESD value for the adult chest X-ray examination was the highest (0.25 mGy) at GP clinics, followed by private hospitals (0.22 mGy) and public hospitals (0.17 mGy). The median ESD for the adult abdominal X-ray examination at public hospitals (3.35 mGy) was higher than that for private hospitals (2.81 mGy). Results of image quality assessment for the chest X-ray examination show that all facility types have a similar median spatial resolution and low-contrast detectability. For the abdominal X-ray examination, public hospitals have a similar median spatial resolution but larger low-contrast detectability compared with private hospitals. The results of this survey clearly show that there is room for further improvement in performing chest and abdominal X-ray examinations in Malaysia.
format Article
author Hambali, A.S.
Ng, K.H.
Abdullah, B.J.J.
Wang, H.B.
Jamal, N.
Spelic, D.C.
Suleiman, O.H.
author_facet Hambali, A.S.
Ng, K.H.
Abdullah, B.J.J.
Wang, H.B.
Jamal, N.
Spelic, D.C.
Suleiman, O.H.
author_sort Hambali, A.S.
title Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia
title_short Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia
title_full Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia
title_fullStr Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia
title_full_unstemmed Entrance surface dose and image quality: comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia
title_sort entrance surface dose and image quality: comparison of adult chest and abdominal x-ray examinations in general practitioner clinics, public and private hospitals in malaysia
publisher Oxford University Press
publishDate 2009
url http://eprints.um.edu.my/4138/1/Entrance_surface_dose_and_image_quality_comparison_of_adult_chest_and_abdominal_X-ray_examinations_in_general_practitioner_clinics%2C_public_and_private_hospitals_in_Malaysia.pdf
http://eprints.um.edu.my/4138/
https://doi.org/10.1093/rpd/ncp007
_version_ 1643687270764511232
score 13.19449