Axial compression behaviour of circular concrete-filled double-skin steel tubular columns with bolted shear studs: Numerical investigation and design

The concrete-filled double-skin steel tubular (CFDST) columns have recently attracted significant attention for practical engineering constructions. The axial resistance behaviour of CFSDTs can be greatly enhanced by installing bolted shear studs as pin supports for the outer. This is a companion pa...

Full description

Saved in:
Bibliographic Details
Main Authors: Ayough, Pouria, Ibrahim, Zainah, Jameel, Mohammed, Alnahhal, Ahmed Mahmoud
Format: Article
Published: Elsevier 2023
Subjects:
Online Access:http://eprints.um.edu.my/38415/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.38415
record_format eprints
spelling my.um.eprints.384152023-06-28T02:44:32Z http://eprints.um.edu.my/38415/ Axial compression behaviour of circular concrete-filled double-skin steel tubular columns with bolted shear studs: Numerical investigation and design Ayough, Pouria Ibrahim, Zainah Jameel, Mohammed Alnahhal, Ahmed Mahmoud TA Engineering (General). Civil engineering (General) The concrete-filled double-skin steel tubular (CFDST) columns have recently attracted significant attention for practical engineering constructions. The axial resistance behaviour of CFSDTs can be greatly enhanced by installing bolted shear studs as pin supports for the outer. This is a companion paper that expands on the authors' work 1]. The previous paper concentrated on full-scale experimental testing to ascertain the influence of bolted shear studs on the axial resistance of CFSDT columns, while this study focused on finite element (FE) analysis and a simplified design approach for such composite structural members. A three-dimensional FE model for predicting the axial behaviour of circular CFDST columns without and with shear studs was developed and validated using the test results of the specimens' typical failure mechanisms and load-displacement responses. The model was then employed to perform structural analysis by comparing the axial load-displacement curve, internal force distribution, longitudinal stress distribution over the sandwiched concrete, and confinement mechanism of a circular column with bolted shear studs with that of its counterpart without bolted shear studs. Parametric studies were carried out to examine the effects of bolt longitudinal spacing, diameter, length, and yield strength. It was found that the spacing of the bolts-to-width (bs/Do) ratio had significant effects on the axial resistance and ductile performance of columns. Also, a bolt spacing corresponding to bs/Do<0.44 was suggested to attain an acceptable ductile performance in practical application. Verification of the design model revealed that it led to satisfactory predictions of the ultimate strengths of circular CFDST columns without and with shear studs. Elsevier 2023-06 Article PeerReviewed Ayough, Pouria and Ibrahim, Zainah and Jameel, Mohammed and Alnahhal, Ahmed Mahmoud (2023) Axial compression behaviour of circular concrete-filled double-skin steel tubular columns with bolted shear studs: Numerical investigation and design. Journal of Constructional Steel Research, 205. ISSN 0143-974X, DOI https://doi.org/10.1016/j.jcsr.2023.107911 <https://doi.org/10.1016/j.jcsr.2023.107911>. 10.1016/j.jcsr.2023.107911
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Ayough, Pouria
Ibrahim, Zainah
Jameel, Mohammed
Alnahhal, Ahmed Mahmoud
Axial compression behaviour of circular concrete-filled double-skin steel tubular columns with bolted shear studs: Numerical investigation and design
description The concrete-filled double-skin steel tubular (CFDST) columns have recently attracted significant attention for practical engineering constructions. The axial resistance behaviour of CFSDTs can be greatly enhanced by installing bolted shear studs as pin supports for the outer. This is a companion paper that expands on the authors' work 1]. The previous paper concentrated on full-scale experimental testing to ascertain the influence of bolted shear studs on the axial resistance of CFSDT columns, while this study focused on finite element (FE) analysis and a simplified design approach for such composite structural members. A three-dimensional FE model for predicting the axial behaviour of circular CFDST columns without and with shear studs was developed and validated using the test results of the specimens' typical failure mechanisms and load-displacement responses. The model was then employed to perform structural analysis by comparing the axial load-displacement curve, internal force distribution, longitudinal stress distribution over the sandwiched concrete, and confinement mechanism of a circular column with bolted shear studs with that of its counterpart without bolted shear studs. Parametric studies were carried out to examine the effects of bolt longitudinal spacing, diameter, length, and yield strength. It was found that the spacing of the bolts-to-width (bs/Do) ratio had significant effects on the axial resistance and ductile performance of columns. Also, a bolt spacing corresponding to bs/Do<0.44 was suggested to attain an acceptable ductile performance in practical application. Verification of the design model revealed that it led to satisfactory predictions of the ultimate strengths of circular CFDST columns without and with shear studs.
format Article
author Ayough, Pouria
Ibrahim, Zainah
Jameel, Mohammed
Alnahhal, Ahmed Mahmoud
author_facet Ayough, Pouria
Ibrahim, Zainah
Jameel, Mohammed
Alnahhal, Ahmed Mahmoud
author_sort Ayough, Pouria
title Axial compression behaviour of circular concrete-filled double-skin steel tubular columns with bolted shear studs: Numerical investigation and design
title_short Axial compression behaviour of circular concrete-filled double-skin steel tubular columns with bolted shear studs: Numerical investigation and design
title_full Axial compression behaviour of circular concrete-filled double-skin steel tubular columns with bolted shear studs: Numerical investigation and design
title_fullStr Axial compression behaviour of circular concrete-filled double-skin steel tubular columns with bolted shear studs: Numerical investigation and design
title_full_unstemmed Axial compression behaviour of circular concrete-filled double-skin steel tubular columns with bolted shear studs: Numerical investigation and design
title_sort axial compression behaviour of circular concrete-filled double-skin steel tubular columns with bolted shear studs: numerical investigation and design
publisher Elsevier
publishDate 2023
url http://eprints.um.edu.my/38415/
_version_ 1770551493465735168
score 13.159267