Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery

In this paper, a numerical investigation is carried out to study the blood flow behavior within the stenosis artery. An artery is under applying a constant heat flux on the boundary walls in this simulation. Lumen model is employed for simulation of the artery and the Sisko model is used to indicate...

Full description

Saved in:
Bibliographic Details
Main Authors: Haowei, M. A., Hussein, Uday Abdul-Reda, Al-Qaim, Zahraa Haleem, Altalbawy, Farag M. A., AI Sadi, Hafidh l., Fadhil, Ali Abdulhussain, Al-Taee, Muataz Mohammed, Hadrawi, Salema K., Khalaf, Reem Muhsin, Jirjees, Iman Hazim, Zarringhalam, Majid, Hekmatifar, Maboud
Format: Article
Published: Elsevier 2023
Subjects:
Online Access:http://eprints.um.edu.my/38338/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.38338
record_format eprints
spelling my.um.eprints.383382024-11-08T02:41:39Z http://eprints.um.edu.my/38338/ Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery Haowei, M. A. Hussein, Uday Abdul-Reda Al-Qaim, Zahraa Haleem Altalbawy, Farag M. A. AI Sadi, Hafidh l. Fadhil, Ali Abdulhussain Al-Taee, Muataz Mohammed Hadrawi, Salema K. Khalaf, Reem Muhsin Jirjees, Iman Hazim Zarringhalam, Majid Hekmatifar, Maboud T Technology (General) TJ Mechanical engineering and machinery In this paper, a numerical investigation is carried out to study the blood flow behavior within the stenosis artery. An artery is under applying a constant heat flux on the boundary walls in this simulation. Lumen model is employed for simulation of the artery and the Sisko model is used to indicate properties of blood as non-Newtonian fluid. Also, the cone geometry of stenosis with different severities and radii are simulated. Then, effects of heat flux, different severities of stenosis, and different radii of the artery are studied on the blood flow behavior. It is reported that before stenosis, velocity is increasing and heat transfer rate is also increasing which cause temperature to be decreased in stenosis position. But after stenosis, velocity is decreased. Consequently, heat transfer rate is decreased which leads to reduction in blood temperature. Also, since the blood par-ticles adhere to the arterial wall, with increasing radial distance from the walls, velocity is increased, which causes maximum velocity to be found in the central region. Moreover, the thermal driving force is damped in the lateral region of the artery and does not affect velocity. On the other side, as the severity increases step by step, the temperature decreases, respectively. In fact, the cross-sectional area decreases with increasing severity of stenosis. Consequently, velocity increases and causes heat transfer enhancement, which leads to a reduction in blood temperature. Therefore, the highest temperatures are related to the artery with an intensity of 20%. Although the cross-section area of the artery can change blood temperature, but its role can be ignorable in temperature enhancement and body healthy in this regard.(c) 2023 THE AUTHORS. Published by Elsevier BV on behalf of Faculty of Engineering, Alexandria University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/). Elsevier 2023-04 Article PeerReviewed Haowei, M. A. and Hussein, Uday Abdul-Reda and Al-Qaim, Zahraa Haleem and Altalbawy, Farag M. A. and AI Sadi, Hafidh l. and Fadhil, Ali Abdulhussain and Al-Taee, Muataz Mohammed and Hadrawi, Salema K. and Khalaf, Reem Muhsin and Jirjees, Iman Hazim and Zarringhalam, Majid and Hekmatifar, Maboud (2023) Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery. Alexandria Engineering Journal, 68. pp. 291-300. ISSN 1110-0168, DOI https://doi.org/10.1016/j.aej.2022.12.048 <https://doi.org/10.1016/j.aej.2022.12.048>. 10.1016/j.aej.2022.12.048
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic T Technology (General)
TJ Mechanical engineering and machinery
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
Haowei, M. A.
Hussein, Uday Abdul-Reda
Al-Qaim, Zahraa Haleem
Altalbawy, Farag M. A.
AI Sadi, Hafidh l.
Fadhil, Ali Abdulhussain
Al-Taee, Muataz Mohammed
Hadrawi, Salema K.
Khalaf, Reem Muhsin
Jirjees, Iman Hazim
Zarringhalam, Majid
Hekmatifar, Maboud
Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
description In this paper, a numerical investigation is carried out to study the blood flow behavior within the stenosis artery. An artery is under applying a constant heat flux on the boundary walls in this simulation. Lumen model is employed for simulation of the artery and the Sisko model is used to indicate properties of blood as non-Newtonian fluid. Also, the cone geometry of stenosis with different severities and radii are simulated. Then, effects of heat flux, different severities of stenosis, and different radii of the artery are studied on the blood flow behavior. It is reported that before stenosis, velocity is increasing and heat transfer rate is also increasing which cause temperature to be decreased in stenosis position. But after stenosis, velocity is decreased. Consequently, heat transfer rate is decreased which leads to reduction in blood temperature. Also, since the blood par-ticles adhere to the arterial wall, with increasing radial distance from the walls, velocity is increased, which causes maximum velocity to be found in the central region. Moreover, the thermal driving force is damped in the lateral region of the artery and does not affect velocity. On the other side, as the severity increases step by step, the temperature decreases, respectively. In fact, the cross-sectional area decreases with increasing severity of stenosis. Consequently, velocity increases and causes heat transfer enhancement, which leads to a reduction in blood temperature. Therefore, the highest temperatures are related to the artery with an intensity of 20%. Although the cross-section area of the artery can change blood temperature, but its role can be ignorable in temperature enhancement and body healthy in this regard.(c) 2023 THE AUTHORS. Published by Elsevier BV on behalf of Faculty of Engineering, Alexandria University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
format Article
author Haowei, M. A.
Hussein, Uday Abdul-Reda
Al-Qaim, Zahraa Haleem
Altalbawy, Farag M. A.
AI Sadi, Hafidh l.
Fadhil, Ali Abdulhussain
Al-Taee, Muataz Mohammed
Hadrawi, Salema K.
Khalaf, Reem Muhsin
Jirjees, Iman Hazim
Zarringhalam, Majid
Hekmatifar, Maboud
author_facet Haowei, M. A.
Hussein, Uday Abdul-Reda
Al-Qaim, Zahraa Haleem
Altalbawy, Farag M. A.
AI Sadi, Hafidh l.
Fadhil, Ali Abdulhussain
Al-Taee, Muataz Mohammed
Hadrawi, Salema K.
Khalaf, Reem Muhsin
Jirjees, Iman Hazim
Zarringhalam, Majid
Hekmatifar, Maboud
author_sort Haowei, M. A.
title Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
title_short Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
title_full Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
title_fullStr Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
title_full_unstemmed Employing Sisko non-Newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: Effects of heat flux, different severities of stenosis, and different radii of the artery
title_sort employing sisko non-newtonian model to investigate the thermal behavior of blood flow in a stenosis artery: effects of heat flux, different severities of stenosis, and different radii of the artery
publisher Elsevier
publishDate 2023
url http://eprints.um.edu.my/38338/
_version_ 1816130393419546624
score 13.214268