Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors

Three different electrodes modified with carbon paste (CP), silk-screen (SP) and poly(vinyl chloride) (PVC) were obtained to verify the reliability of AVELOX, the generic name of which is Moxifloxacin HCL (AV-MOXH). The sensing membranes were containing AVELOX ion associated complexes with sodium te...

Full description

Saved in:
Bibliographic Details
Main Authors: Kumar, Sachin, Sindhu, Sushil K., Kumar, Praveen, Sharma, Amit, Sagadevan, Suresh
Format: Article
Published: Industrial Chemistry Research Inst 2021
Subjects:
Online Access:http://eprints.um.edu.my/35321/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.35321
record_format eprints
spelling my.um.eprints.353212022-10-14T05:21:54Z http://eprints.um.edu.my/35321/ Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors Kumar, Sachin Sindhu, Sushil K. Kumar, Praveen Sharma, Amit Sagadevan, Suresh QC Physics QD Chemistry Three different electrodes modified with carbon paste (CP), silk-screen (SP) and poly(vinyl chloride) (PVC) were obtained to verify the reliability of AVELOX, the generic name of which is Moxifloxacin HCL (AV-MOXH). The sensing membranes were containing AVELOX ion associated complexes with sodium tetraphenylborate (NaTPB), phosphomolybdic acid (PMA), phosphotungstic acid (PTA), and ammonium reineckate (RN) as electroactive materials. All three electrodes gave fast, viable, and near-Nernstian linear responses over a relative wide concentration range that ranged from 1.0.10(-6) to 1.0.10(-2) mol/l AV-MOXH at 25 degrees C with a monovalent cationic decrease. The sensors demonstrated a good discernment of AV-MOXH from numerous inorganic and organic compounds such as glucose, sucrose, Na+, Ca2+ etc. Additionally, the isothermal coefficients along with selectivity coefficients were calculated. The modified Screen Printed Electrode sensor appeared to be highly sensitive for the determination of AV-MOXH. The electrode response was observed in pH range 2-6 for ISPE electrodes and IPVC electrodes and 3-7 for ICPE electrodes under various temperature conditions. The short response time, lifetime validity, recovery, and all the methods of validation such as limit of detection and limit of quantification were estimated. The potentiometric method turned out to be suitable for determining AV-MOXH in pharmacological formulations, and the findings obtained are comparable to the ``HPLC official method'' in terms of the agreement. As a result, the postulated potentiometric approach was verified in accordance with IUPAC guidelines. Industrial Chemistry Research Inst 2021-11 Article PeerReviewed Kumar, Sachin and Sindhu, Sushil K. and Kumar, Praveen and Sharma, Amit and Sagadevan, Suresh (2021) Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors. Polimery, 66 (11-12). pp. 589-601. ISSN 0032-2725, DOI https://doi.org/10.14314/polimery.2021.11.4 <https://doi.org/10.14314/polimery.2021.11.4>. 10.14314/polimery.2021.11.4
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic QC Physics
QD Chemistry
spellingShingle QC Physics
QD Chemistry
Kumar, Sachin
Sindhu, Sushil K.
Kumar, Praveen
Sharma, Amit
Sagadevan, Suresh
Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors
description Three different electrodes modified with carbon paste (CP), silk-screen (SP) and poly(vinyl chloride) (PVC) were obtained to verify the reliability of AVELOX, the generic name of which is Moxifloxacin HCL (AV-MOXH). The sensing membranes were containing AVELOX ion associated complexes with sodium tetraphenylborate (NaTPB), phosphomolybdic acid (PMA), phosphotungstic acid (PTA), and ammonium reineckate (RN) as electroactive materials. All three electrodes gave fast, viable, and near-Nernstian linear responses over a relative wide concentration range that ranged from 1.0.10(-6) to 1.0.10(-2) mol/l AV-MOXH at 25 degrees C with a monovalent cationic decrease. The sensors demonstrated a good discernment of AV-MOXH from numerous inorganic and organic compounds such as glucose, sucrose, Na+, Ca2+ etc. Additionally, the isothermal coefficients along with selectivity coefficients were calculated. The modified Screen Printed Electrode sensor appeared to be highly sensitive for the determination of AV-MOXH. The electrode response was observed in pH range 2-6 for ISPE electrodes and IPVC electrodes and 3-7 for ICPE electrodes under various temperature conditions. The short response time, lifetime validity, recovery, and all the methods of validation such as limit of detection and limit of quantification were estimated. The potentiometric method turned out to be suitable for determining AV-MOXH in pharmacological formulations, and the findings obtained are comparable to the ``HPLC official method'' in terms of the agreement. As a result, the postulated potentiometric approach was verified in accordance with IUPAC guidelines.
format Article
author Kumar, Sachin
Sindhu, Sushil K.
Kumar, Praveen
Sharma, Amit
Sagadevan, Suresh
author_facet Kumar, Sachin
Sindhu, Sushil K.
Kumar, Praveen
Sharma, Amit
Sagadevan, Suresh
author_sort Kumar, Sachin
title Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors
title_short Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors
title_full Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors
title_fullStr Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors
title_full_unstemmed Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors
title_sort determination of moxifloxacin hydrochloride in avelox pharmacological formulations using modified potentiometer sensors
publisher Industrial Chemistry Research Inst
publishDate 2021
url http://eprints.um.edu.my/35321/
_version_ 1748181075775979520
score 13.160551