Wide area measurement system in the IEEE-14 bus system using multiobjective shortest path algorithm for fault analysis

In a large-scale interconnected power system network, few challenges exist in evaluating and maintaining the overall system stability. The power system's ability to supply all types of loads during natural disasters or faults has yet to be addressed. This work focuses on developing a wide-area...

Full description

Saved in:
Bibliographic Details
Main Authors: Awalin, Lilik J., Abd Halim, Syahirah, Jamaludin, Jafferi, Ramli, Nor Azuana
Format: Article
Published: SAI Organization 2021
Subjects:
Online Access:http://eprints.um.edu.my/35109/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.35109
record_format eprints
spelling my.um.eprints.351092022-09-07T01:59:15Z http://eprints.um.edu.my/35109/ Wide area measurement system in the IEEE-14 bus system using multiobjective shortest path algorithm for fault analysis Awalin, Lilik J. Abd Halim, Syahirah Jamaludin, Jafferi Ramli, Nor Azuana QA75 Electronic computers. Computer science In a large-scale interconnected power system network, few challenges exist in evaluating and maintaining the overall system stability. The power system's ability to supply all types of loads during natural disasters or faults has yet to be addressed. This work focuses on developing a wide-area measurement system to manage and control the power system under all operating conditions. The IEEE-14 bus system was modeled in PSCAD software for simulating nineteen types of fault based on multi-objective shortest path algorithm. To manage the wide area measurement, the research must comprehend the working principle of the multi-objective shortest path algorithm, whereby the proposed method will determine the new path for the IEEE-14 bus system. To evaluate the performance of the multi-objective shortest path algorithm, all sections of the IEEE-14 bus system were simulated with faults. The distances of the normal path (without simulated fault) and the new path (with simulated fault) were recorded. Based on the recorded data, it was found that the location of the fault has significant influence on the shortest path of the buses connected to each other. SAI Organization 2021-09 Article PeerReviewed Awalin, Lilik J. and Abd Halim, Syahirah and Jamaludin, Jafferi and Ramli, Nor Azuana (2021) Wide area measurement system in the IEEE-14 bus system using multiobjective shortest path algorithm for fault analysis. International Journal of Advanced Computer Science and Applications, 12 (9). pp. 96-101. ISSN 2158-107X,
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic QA75 Electronic computers. Computer science
spellingShingle QA75 Electronic computers. Computer science
Awalin, Lilik J.
Abd Halim, Syahirah
Jamaludin, Jafferi
Ramli, Nor Azuana
Wide area measurement system in the IEEE-14 bus system using multiobjective shortest path algorithm for fault analysis
description In a large-scale interconnected power system network, few challenges exist in evaluating and maintaining the overall system stability. The power system's ability to supply all types of loads during natural disasters or faults has yet to be addressed. This work focuses on developing a wide-area measurement system to manage and control the power system under all operating conditions. The IEEE-14 bus system was modeled in PSCAD software for simulating nineteen types of fault based on multi-objective shortest path algorithm. To manage the wide area measurement, the research must comprehend the working principle of the multi-objective shortest path algorithm, whereby the proposed method will determine the new path for the IEEE-14 bus system. To evaluate the performance of the multi-objective shortest path algorithm, all sections of the IEEE-14 bus system were simulated with faults. The distances of the normal path (without simulated fault) and the new path (with simulated fault) were recorded. Based on the recorded data, it was found that the location of the fault has significant influence on the shortest path of the buses connected to each other.
format Article
author Awalin, Lilik J.
Abd Halim, Syahirah
Jamaludin, Jafferi
Ramli, Nor Azuana
author_facet Awalin, Lilik J.
Abd Halim, Syahirah
Jamaludin, Jafferi
Ramli, Nor Azuana
author_sort Awalin, Lilik J.
title Wide area measurement system in the IEEE-14 bus system using multiobjective shortest path algorithm for fault analysis
title_short Wide area measurement system in the IEEE-14 bus system using multiobjective shortest path algorithm for fault analysis
title_full Wide area measurement system in the IEEE-14 bus system using multiobjective shortest path algorithm for fault analysis
title_fullStr Wide area measurement system in the IEEE-14 bus system using multiobjective shortest path algorithm for fault analysis
title_full_unstemmed Wide area measurement system in the IEEE-14 bus system using multiobjective shortest path algorithm for fault analysis
title_sort wide area measurement system in the ieee-14 bus system using multiobjective shortest path algorithm for fault analysis
publisher SAI Organization
publishDate 2021
url http://eprints.um.edu.my/35109/
_version_ 1744649213802708992