Detection of Escherichia coli K12 in Water Using Slot Waveguide in Cascaded Ring Resonator
Escherichia coli (E. coli) bacteria can cause serious fatal health problems in human, thus early and quick pathogen detection of these bacteria is a crucial issue in hospitals, food industry, and pharmaceutical companies. Detection of E. coli K12 in drinking water source can be considered of water p...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
Springer
2022
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/33856/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.33856 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.338562022-04-23T03:51:14Z http://eprints.um.edu.my/33856/ Detection of Escherichia coli K12 in Water Using Slot Waveguide in Cascaded Ring Resonator Sanati, Parisa Hashemi, Seyedeh-Sara Bahadoran, Mahdi Babadi, Arman Amani Akbari, Elnaz QD Chemistry Escherichia coli (E. coli) bacteria can cause serious fatal health problems in human, thus early and quick pathogen detection of these bacteria is a crucial issue in hospitals, food industry, and pharmaceutical companies. Detection of E. coli K12 in drinking water source can be considered of water pollution with sewage that is vitally important in public health service. In this work, a plasmonic slot waveguide from Si3N(4)-SiO2 is designed and applied in an asymmetric double stage ring resonator (DSRR) for the label free detection of E. coli K12 in drinking water. The performance of DSRR sensor is studied for different concentrations of Nacl and sucrose solutions and a contaminated water sample with E.coli K12 using variational finite-difference time domain (var-FDTD) method. The sensitivity of the DSRR sensor for detection of E. coli K12 in the visible wavelengths is measured to be 461-480 nm/RIU, which leads to the minimum limit of detection (LOD) of 3.33x 10(-5). In comparison with the conventional devices and methods for detection of E. coli bacterium, our proposed sensor benefits of microscale size, high resolution sensing, and short time of detection. Springer 2022-02 Article PeerReviewed Sanati, Parisa and Hashemi, Seyedeh-Sara and Bahadoran, Mahdi and Babadi, Arman Amani and Akbari, Elnaz (2022) Detection of Escherichia coli K12 in Water Using Slot Waveguide in Cascaded Ring Resonator. Silicon, 14 (3). pp. 851-857. ISSN 1876-990X, DOI https://doi.org/10.1007/s12633-020-00896-2 <https://doi.org/10.1007/s12633-020-00896-2>. 10.1007/s12633-020-00896-2 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
QD Chemistry |
spellingShingle |
QD Chemistry Sanati, Parisa Hashemi, Seyedeh-Sara Bahadoran, Mahdi Babadi, Arman Amani Akbari, Elnaz Detection of Escherichia coli K12 in Water Using Slot Waveguide in Cascaded Ring Resonator |
description |
Escherichia coli (E. coli) bacteria can cause serious fatal health problems in human, thus early and quick pathogen detection of these bacteria is a crucial issue in hospitals, food industry, and pharmaceutical companies. Detection of E. coli K12 in drinking water source can be considered of water pollution with sewage that is vitally important in public health service. In this work, a plasmonic slot waveguide from Si3N(4)-SiO2 is designed and applied in an asymmetric double stage ring resonator (DSRR) for the label free detection of E. coli K12 in drinking water. The performance of DSRR sensor is studied for different concentrations of Nacl and sucrose solutions and a contaminated water sample with E.coli K12 using variational finite-difference time domain (var-FDTD) method. The sensitivity of the DSRR sensor for detection of E. coli K12 in the visible wavelengths is measured to be 461-480 nm/RIU, which leads to the minimum limit of detection (LOD) of 3.33x 10(-5). In comparison with the conventional devices and methods for detection of E. coli bacterium, our proposed sensor benefits of microscale size, high resolution sensing, and short time of detection. |
format |
Article |
author |
Sanati, Parisa Hashemi, Seyedeh-Sara Bahadoran, Mahdi Babadi, Arman Amani Akbari, Elnaz |
author_facet |
Sanati, Parisa Hashemi, Seyedeh-Sara Bahadoran, Mahdi Babadi, Arman Amani Akbari, Elnaz |
author_sort |
Sanati, Parisa |
title |
Detection of Escherichia coli K12 in Water Using Slot Waveguide in Cascaded Ring Resonator |
title_short |
Detection of Escherichia coli K12 in Water Using Slot Waveguide in Cascaded Ring Resonator |
title_full |
Detection of Escherichia coli K12 in Water Using Slot Waveguide in Cascaded Ring Resonator |
title_fullStr |
Detection of Escherichia coli K12 in Water Using Slot Waveguide in Cascaded Ring Resonator |
title_full_unstemmed |
Detection of Escherichia coli K12 in Water Using Slot Waveguide in Cascaded Ring Resonator |
title_sort |
detection of escherichia coli k12 in water using slot waveguide in cascaded ring resonator |
publisher |
Springer |
publishDate |
2022 |
url |
http://eprints.um.edu.my/33856/ |
_version_ |
1735409600138575872 |
score |
13.214268 |