Determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) and high-performance liquid chromatography - diode array detection (HPLC-DAD)

Endocrine-disrupting compounds are routinely detected in environmental water. In this study, a simple and rapid sample preparation method based on ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) followed by high performance liquid chromatography - diode array detection (H...

Full description

Saved in:
Bibliographic Details
Main Authors: Rozaini, Muhammad Nur' Hafiz, Saad, Bahruddin, Yahaya, Noorfatimah, Lim, Jun Wei, Aris, Muhammad Naeim Mohd, Ramachandran, Muggundha Raoov
Format: Article
Published: Taylor & Francis 2022
Subjects:
Online Access:http://eprints.um.edu.my/33832/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.33832
record_format eprints
spelling my.um.eprints.338322022-04-25T07:36:00Z http://eprints.um.edu.my/33832/ Determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) and high-performance liquid chromatography - diode array detection (HPLC-DAD) Rozaini, Muhammad Nur' Hafiz Saad, Bahruddin Yahaya, Noorfatimah Lim, Jun Wei Aris, Muhammad Naeim Mohd Ramachandran, Muggundha Raoov QD Chemistry Endocrine-disrupting compounds are routinely detected in environmental water. In this study, a simple and rapid sample preparation method based on ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) followed by high performance liquid chromatography - diode array detection (HPLC-DAD) was developed for the determination of triclosan, triclocarban and methyl-triclosan in water. Parameters that affect the extraction efficiency - such as type and mass of salt, type and volume of extraction solvent, extraction time, sample pH and sample volume - were studied. Under the optimized conditions, the method demonstrated linearity from 0.18 to 1000 mu g L-1 with coefficients of determination R-2 >= 0.9899, limits of detection from 0.05 to 0.2 mu g L-1, and good recoveries (> 70%) with relative standard deviations < 10%. The method was applied for the determination of triclosan, triclocarban, and methyl-triclosan in swimming pool, lake, and wastewater. The greenness of the method was quantified using the Analytical Eco-Scale Index. Taylor & Francis 2022-01-02 Article PeerReviewed Rozaini, Muhammad Nur' Hafiz and Saad, Bahruddin and Yahaya, Noorfatimah and Lim, Jun Wei and Aris, Muhammad Naeim Mohd and Ramachandran, Muggundha Raoov (2022) Determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) and high-performance liquid chromatography - diode array detection (HPLC-DAD). Analytical Letters, 55 (1). pp. 132-145. ISSN 0003-2719, DOI https://doi.org/10.1080/00032719.2021.1919691 <https://doi.org/10.1080/00032719.2021.1919691>. 10.1080/00032719.2021.1919691
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic QD Chemistry
spellingShingle QD Chemistry
Rozaini, Muhammad Nur' Hafiz
Saad, Bahruddin
Yahaya, Noorfatimah
Lim, Jun Wei
Aris, Muhammad Naeim Mohd
Ramachandran, Muggundha Raoov
Determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) and high-performance liquid chromatography - diode array detection (HPLC-DAD)
description Endocrine-disrupting compounds are routinely detected in environmental water. In this study, a simple and rapid sample preparation method based on ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) followed by high performance liquid chromatography - diode array detection (HPLC-DAD) was developed for the determination of triclosan, triclocarban and methyl-triclosan in water. Parameters that affect the extraction efficiency - such as type and mass of salt, type and volume of extraction solvent, extraction time, sample pH and sample volume - were studied. Under the optimized conditions, the method demonstrated linearity from 0.18 to 1000 mu g L-1 with coefficients of determination R-2 >= 0.9899, limits of detection from 0.05 to 0.2 mu g L-1, and good recoveries (> 70%) with relative standard deviations < 10%. The method was applied for the determination of triclosan, triclocarban, and methyl-triclosan in swimming pool, lake, and wastewater. The greenness of the method was quantified using the Analytical Eco-Scale Index.
format Article
author Rozaini, Muhammad Nur' Hafiz
Saad, Bahruddin
Yahaya, Noorfatimah
Lim, Jun Wei
Aris, Muhammad Naeim Mohd
Ramachandran, Muggundha Raoov
author_facet Rozaini, Muhammad Nur' Hafiz
Saad, Bahruddin
Yahaya, Noorfatimah
Lim, Jun Wei
Aris, Muhammad Naeim Mohd
Ramachandran, Muggundha Raoov
author_sort Rozaini, Muhammad Nur' Hafiz
title Determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) and high-performance liquid chromatography - diode array detection (HPLC-DAD)
title_short Determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) and high-performance liquid chromatography - diode array detection (HPLC-DAD)
title_full Determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) and high-performance liquid chromatography - diode array detection (HPLC-DAD)
title_fullStr Determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) and high-performance liquid chromatography - diode array detection (HPLC-DAD)
title_full_unstemmed Determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (UA-SI-LLME) and high-performance liquid chromatography - diode array detection (HPLC-DAD)
title_sort determination of three endocrine disruptors in water samples by ultrasound-assisted salt-induced liquid-liquid microextraction (ua-si-llme) and high-performance liquid chromatography - diode array detection (hplc-dad)
publisher Taylor & Francis
publishDate 2022
url http://eprints.um.edu.my/33832/
_version_ 1735409597086171136
score 13.188404