New designs of paper based analytical devices (PADs) for completing replication analysis of a sample within a single run by employing smartphone

Paper-based analytical devices (PADs) with four new designs could be fabricated using commercially available home-based scan-and-cut printer. They serve for miniaturised platforms for chemical analysis. Replication analysis of a sample together with the calibration (using the analyte standards at di...

Full description

Saved in:
Bibliographic Details
Main Authors: Kiwfo, Kanokwan, Woi, Pei Meng, Seanjum, Chalermpong, Grudpan, Kate
Format: Article
Published: Elsevier 2022
Subjects:
Online Access:http://eprints.um.edu.my/33780/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.33780
record_format eprints
spelling my.um.eprints.337802022-04-27T03:59:02Z http://eprints.um.edu.my/33780/ New designs of paper based analytical devices (PADs) for completing replication analysis of a sample within a single run by employing smartphone Kiwfo, Kanokwan Woi, Pei Meng Seanjum, Chalermpong Grudpan, Kate T Technology (General) TP Chemical technology Paper-based analytical devices (PADs) with four new designs could be fabricated using commercially available home-based scan-and-cut printer. They serve for miniaturised platforms for chemical analysis. Replication analysis of a sample together with the calibration (using the analyte standards at different concentrations) can be completed in a single run, by utilising smartphone as the detector. Some new approaches for choosing detection zones were suggested. The four proposed PAD designs here were used as models in microliter scale operation to demonstrate the well-known chemistries of colorimetric determinations of iron, phosphate, and hardness using 1,10-phenanthroline and simple aqueous guava leaf extract; molybdate, and EBT-EDTA complexometric titration, respectively, through calibrations: where Blue (B) value = 88.2log Fe3+] - 80.8, R-2 = 0.989; B value = 1.75 Fe3+] + 0.198, R-2 = 0.999; Grey scale (I) value = 1.77 Fe3+] - 1.22, R-2 = 0.997; Red (R) value = 16.1log PO43-] + 8.95, R-2 = 0.999; Hue (H) value = 43.3log Ca2+] + 233, R-2 = 0.994, respectively. For the hardness, using one of the PAD designs, true titration was also possible. Applications of the proposed devices and procedures were demonstrated for real world samples with validation. Additionally, kinetic study of the molybdenum blue for phosphate was demonstrated using one of the PADs. Elsevier 2022-01-01 Article PeerReviewed Kiwfo, Kanokwan and Woi, Pei Meng and Seanjum, Chalermpong and Grudpan, Kate (2022) New designs of paper based analytical devices (PADs) for completing replication analysis of a sample within a single run by employing smartphone. Talanta, 236. ISSN 0039-9140, DOI https://doi.org/10.1016/j.talanta.2021.122848 <https://doi.org/10.1016/j.talanta.2021.122848>. 10.1016/j.talanta.2021.122848
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic T Technology (General)
TP Chemical technology
spellingShingle T Technology (General)
TP Chemical technology
Kiwfo, Kanokwan
Woi, Pei Meng
Seanjum, Chalermpong
Grudpan, Kate
New designs of paper based analytical devices (PADs) for completing replication analysis of a sample within a single run by employing smartphone
description Paper-based analytical devices (PADs) with four new designs could be fabricated using commercially available home-based scan-and-cut printer. They serve for miniaturised platforms for chemical analysis. Replication analysis of a sample together with the calibration (using the analyte standards at different concentrations) can be completed in a single run, by utilising smartphone as the detector. Some new approaches for choosing detection zones were suggested. The four proposed PAD designs here were used as models in microliter scale operation to demonstrate the well-known chemistries of colorimetric determinations of iron, phosphate, and hardness using 1,10-phenanthroline and simple aqueous guava leaf extract; molybdate, and EBT-EDTA complexometric titration, respectively, through calibrations: where Blue (B) value = 88.2log Fe3+] - 80.8, R-2 = 0.989; B value = 1.75 Fe3+] + 0.198, R-2 = 0.999; Grey scale (I) value = 1.77 Fe3+] - 1.22, R-2 = 0.997; Red (R) value = 16.1log PO43-] + 8.95, R-2 = 0.999; Hue (H) value = 43.3log Ca2+] + 233, R-2 = 0.994, respectively. For the hardness, using one of the PAD designs, true titration was also possible. Applications of the proposed devices and procedures were demonstrated for real world samples with validation. Additionally, kinetic study of the molybdenum blue for phosphate was demonstrated using one of the PADs.
format Article
author Kiwfo, Kanokwan
Woi, Pei Meng
Seanjum, Chalermpong
Grudpan, Kate
author_facet Kiwfo, Kanokwan
Woi, Pei Meng
Seanjum, Chalermpong
Grudpan, Kate
author_sort Kiwfo, Kanokwan
title New designs of paper based analytical devices (PADs) for completing replication analysis of a sample within a single run by employing smartphone
title_short New designs of paper based analytical devices (PADs) for completing replication analysis of a sample within a single run by employing smartphone
title_full New designs of paper based analytical devices (PADs) for completing replication analysis of a sample within a single run by employing smartphone
title_fullStr New designs of paper based analytical devices (PADs) for completing replication analysis of a sample within a single run by employing smartphone
title_full_unstemmed New designs of paper based analytical devices (PADs) for completing replication analysis of a sample within a single run by employing smartphone
title_sort new designs of paper based analytical devices (pads) for completing replication analysis of a sample within a single run by employing smartphone
publisher Elsevier
publishDate 2022
url http://eprints.um.edu.my/33780/
_version_ 1735409590524182528
score 13.211869