Association of radiation doses and cancer risks from CT pulmonary angiography examinations in relation to body diameter

In this study, we aimed to estimate the probability of cancer risk induced by CT pulmonary angiography (CTPA) examinations concerning effective body diameter. One hundred patients who underwent CTPA examinations were recruited as subjects from a single institution in Kuala Lumpur. Subjects were cate...

Full description

Saved in:
Bibliographic Details
Main Authors: Harun, Hanif Haspi, Karim, Muhammad Khalis Abdul, Abbas, Zulkifly, Rahman, Mohd Amir Abdul, Sabarudin, Akmal, Ng, Kwan Hoong
Format: Article
Published: MDPI 2020
Subjects:
Online Access:http://eprints.um.edu.my/31688/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.31688
record_format eprints
spelling my.um.eprints.316882022-09-28T04:47:17Z http://eprints.um.edu.my/31688/ Association of radiation doses and cancer risks from CT pulmonary angiography examinations in relation to body diameter Harun, Hanif Haspi Karim, Muhammad Khalis Abdul Abbas, Zulkifly Rahman, Mohd Amir Abdul Sabarudin, Akmal Ng, Kwan Hoong RC Internal medicine In this study, we aimed to estimate the probability of cancer risk induced by CT pulmonary angiography (CTPA) examinations concerning effective body diameter. One hundred patients who underwent CTPA examinations were recruited as subjects from a single institution in Kuala Lumpur. Subjects were categorized based on their effective diameter size, where 19-25, 25-28, and >28 cm categorized as Groups 1, 2, and 3, respectively. The mean value of the body diameter of the subjects was 26.82 +/- 3.12 cm, with no significant differences found between male and female subjects. The risk of cancer in breast, lung, and liver organs was 0.009%, 0.007%, and 0.005% respectively. The volume-weighted CT dose index (CTDIvol) was underestimated, whereas the size-specific dose estimates (SSDEs) provided a more accurate description of the radiation dose and the risk of cancer. CTPA examinations are considered safe but it is essential to implement a protocol optimized following the As Low as Reasonably Achievable (ALARA) principle. MDPI 2020-09 Article PeerReviewed Harun, Hanif Haspi and Karim, Muhammad Khalis Abdul and Abbas, Zulkifly and Rahman, Mohd Amir Abdul and Sabarudin, Akmal and Ng, Kwan Hoong (2020) Association of radiation doses and cancer risks from CT pulmonary angiography examinations in relation to body diameter. Diagnostics, 10 (9). ISSN 2075-4418, DOI https://doi.org/10.3390/diagnostics10090681 <https://doi.org/10.3390/diagnostics10090681>. 10.3390/diagnostics10090681
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic RC Internal medicine
spellingShingle RC Internal medicine
Harun, Hanif Haspi
Karim, Muhammad Khalis Abdul
Abbas, Zulkifly
Rahman, Mohd Amir Abdul
Sabarudin, Akmal
Ng, Kwan Hoong
Association of radiation doses and cancer risks from CT pulmonary angiography examinations in relation to body diameter
description In this study, we aimed to estimate the probability of cancer risk induced by CT pulmonary angiography (CTPA) examinations concerning effective body diameter. One hundred patients who underwent CTPA examinations were recruited as subjects from a single institution in Kuala Lumpur. Subjects were categorized based on their effective diameter size, where 19-25, 25-28, and >28 cm categorized as Groups 1, 2, and 3, respectively. The mean value of the body diameter of the subjects was 26.82 +/- 3.12 cm, with no significant differences found between male and female subjects. The risk of cancer in breast, lung, and liver organs was 0.009%, 0.007%, and 0.005% respectively. The volume-weighted CT dose index (CTDIvol) was underestimated, whereas the size-specific dose estimates (SSDEs) provided a more accurate description of the radiation dose and the risk of cancer. CTPA examinations are considered safe but it is essential to implement a protocol optimized following the As Low as Reasonably Achievable (ALARA) principle.
format Article
author Harun, Hanif Haspi
Karim, Muhammad Khalis Abdul
Abbas, Zulkifly
Rahman, Mohd Amir Abdul
Sabarudin, Akmal
Ng, Kwan Hoong
author_facet Harun, Hanif Haspi
Karim, Muhammad Khalis Abdul
Abbas, Zulkifly
Rahman, Mohd Amir Abdul
Sabarudin, Akmal
Ng, Kwan Hoong
author_sort Harun, Hanif Haspi
title Association of radiation doses and cancer risks from CT pulmonary angiography examinations in relation to body diameter
title_short Association of radiation doses and cancer risks from CT pulmonary angiography examinations in relation to body diameter
title_full Association of radiation doses and cancer risks from CT pulmonary angiography examinations in relation to body diameter
title_fullStr Association of radiation doses and cancer risks from CT pulmonary angiography examinations in relation to body diameter
title_full_unstemmed Association of radiation doses and cancer risks from CT pulmonary angiography examinations in relation to body diameter
title_sort association of radiation doses and cancer risks from ct pulmonary angiography examinations in relation to body diameter
publisher MDPI
publishDate 2020
url http://eprints.um.edu.my/31688/
_version_ 1745562735563767808
score 13.186839