Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna

Treatment of radius or ulna nonunion requires both osteogenic environment and mechanical stability. We would like to report three radial and six ulnar diaphyseal nonunions treated with 3.5 mm locking compression plate (LCP) fixation. To assess the effectiveness of 3.5 mm LCP in treating diaphyseal n...

Full description

Saved in:
Bibliographic Details
Main Authors: Ling, H.T., Kwan, M.K., Chua, Y.P., Deepak, A.S., Ahmad, T.S.
Format: Article
Published: MJM 2006
Subjects:
Online Access:http://eprints.um.edu.my/3005/
http://www.ncbi.nlm.nih.gov/pubmed/17600986
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.3005
record_format eprints
spelling my.um.eprints.30052012-05-07T01:19:57Z http://eprints.um.edu.my/3005/ Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna Ling, H.T. Kwan, M.K. Chua, Y.P. Deepak, A.S. Ahmad, T.S. R Medicine Treatment of radius or ulna nonunion requires both osteogenic environment and mechanical stability. We would like to report three radial and six ulnar diaphyseal nonunions treated with 3.5 mm locking compression plate (LCP) fixation. To assess the effectiveness of 3.5 mm LCP in treating diaphyseal nonunion of the forearm bones, we prospectively reviewed nine patients with the mean age of 33 years with diaphyseal nonunion of the radius or ulna. All patients were treated with 3.5 mm LCP. Bone grafting was only performed for atrophic nonunion. Surgical and functional outcome were evaluated. There were three atrophic nonunion of the radius, four atrophic nonunion of the ulna and two hypertrophic nonunion of the ulna. All nonunion united successfully with satisfactory functional outcome. 3.5 mm LCP is effective in the treatment of nonunion of ulna or radius. MJM 2006-12 Article PeerReviewed Ling, H.T. and Kwan, M.K. and Chua, Y.P. and Deepak, A.S. and Ahmad, T.S. (2006) Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna. Medical Journal of Malaysia, 61 B. pp. 8-12. ISSN 0300-5283 http://www.ncbi.nlm.nih.gov/pubmed/17600986
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic R Medicine
spellingShingle R Medicine
Ling, H.T.
Kwan, M.K.
Chua, Y.P.
Deepak, A.S.
Ahmad, T.S.
Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna
description Treatment of radius or ulna nonunion requires both osteogenic environment and mechanical stability. We would like to report three radial and six ulnar diaphyseal nonunions treated with 3.5 mm locking compression plate (LCP) fixation. To assess the effectiveness of 3.5 mm LCP in treating diaphyseal nonunion of the forearm bones, we prospectively reviewed nine patients with the mean age of 33 years with diaphyseal nonunion of the radius or ulna. All patients were treated with 3.5 mm LCP. Bone grafting was only performed for atrophic nonunion. Surgical and functional outcome were evaluated. There were three atrophic nonunion of the radius, four atrophic nonunion of the ulna and two hypertrophic nonunion of the ulna. All nonunion united successfully with satisfactory functional outcome. 3.5 mm LCP is effective in the treatment of nonunion of ulna or radius.
format Article
author Ling, H.T.
Kwan, M.K.
Chua, Y.P.
Deepak, A.S.
Ahmad, T.S.
author_facet Ling, H.T.
Kwan, M.K.
Chua, Y.P.
Deepak, A.S.
Ahmad, T.S.
author_sort Ling, H.T.
title Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna
title_short Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna
title_full Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna
title_fullStr Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna
title_full_unstemmed Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna
title_sort locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna
publisher MJM
publishDate 2006
url http://eprints.um.edu.my/3005/
http://www.ncbi.nlm.nih.gov/pubmed/17600986
_version_ 1643687026803867648
score 13.201949