Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination

Paediatric patients are considered vulnerable to radiation exposure and have a greater risk of developing radiation-induced cancers due to active growth cells. Radiation dose from a CT examination is the highest among other imaging modalities and can become harmful if unoptimised. Thus, the aim of t...

Full description

Saved in:
Bibliographic Details
Main Authors: Karim, M. K. A., Harun, H. H., Kayun, Z., Aljewaw, O. B., Azizan, S. H. N., Rafiz, N. F. N. M., Muhammad, Norazura
Format: Article
Published: Elsevier 2021
Subjects:
Online Access:http://eprints.um.edu.my/28778/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.28778
record_format eprints
spelling my.um.eprints.287782022-08-22T00:27:36Z http://eprints.um.edu.my/28778/ Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination Karim, M. K. A. Harun, H. H. Kayun, Z. Aljewaw, O. B. Azizan, S. H. N. Rafiz, N. F. N. M. Muhammad, Norazura Q Science (General) QC Physics QD Chemistry T Technology (General) Paediatric patients are considered vulnerable to radiation exposure and have a greater risk of developing radiation-induced cancers due to active growth cells. Radiation dose from a CT examination is the highest among other imaging modalities and can become harmful if unoptimised. Thus, the aim of this study is to evaluate the influence of paediatric size on SSDE value and to estimate cancer risk occurrence in specific organs of paediatric patients receiving CT chest examination. Data such as volume-weighted CT dose index (CTDIvol), dose length product (DLP) and patient's demography were retrospectively collected from a 64-slice CT scanner (Siemens Somatom Definition AS+) at University Malaya Medical Centre. A total of 120 patients were categorised into four age groups: G1 (0 - < 1 years), G2 (1 - < 5 years), G3 (5 - < 10 years), and G4 (10 - < 15 years). SSDE value was estimate in accordance with the American Association of Physicists, 2011 in Medicine (AAPM) report 204. The effective dose (E) and SSDENCICT obtained from National Cancer Institute Dosimetry System (NCICT) were then compared to the conventional SSDE value. The highest value of CTDIvol, DLP and E were found in group G4 with 4.9 +/- 2.5, 185.0 +/- 140.8, and 4.2 +/- 2.0, respectively. Moreover, there is only slightly different of SSDE value between the G1 and G2 groups with a factor of 0.91. No significant difference (p > 0.05) was observed between the SSDEAAPM and SSDENCICT across all age groups. The cancer risk estimated shows thyroid organs receives the highest probability of cancer incidence in both the genders, which was calculated to be 2.1 for males and 3.9 for females per 100,000 procedures, respectively. Nevertheless, adequate justification of paediatric CT scans and dose optimisation are required to reduce unnecessary exposure and radiation-induced risks. Elsevier 2021-11 Article PeerReviewed Karim, M. K. A. and Harun, H. H. and Kayun, Z. and Aljewaw, O. B. and Azizan, S. H. N. and Rafiz, N. F. N. M. and Muhammad, Norazura (2021) Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination. Radiation Physics and Chemistry, 188. ISSN 0969-806X, DOI https://doi.org/10.1016/j.radphyschem.2021.109685 <https://doi.org/10.1016/j.radphyschem.2021.109685>. 10.1016/j.radphyschem.2021.109685
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Q Science (General)
QC Physics
QD Chemistry
T Technology (General)
spellingShingle Q Science (General)
QC Physics
QD Chemistry
T Technology (General)
Karim, M. K. A.
Harun, H. H.
Kayun, Z.
Aljewaw, O. B.
Azizan, S. H. N.
Rafiz, N. F. N. M.
Muhammad, Norazura
Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination
description Paediatric patients are considered vulnerable to radiation exposure and have a greater risk of developing radiation-induced cancers due to active growth cells. Radiation dose from a CT examination is the highest among other imaging modalities and can become harmful if unoptimised. Thus, the aim of this study is to evaluate the influence of paediatric size on SSDE value and to estimate cancer risk occurrence in specific organs of paediatric patients receiving CT chest examination. Data such as volume-weighted CT dose index (CTDIvol), dose length product (DLP) and patient's demography were retrospectively collected from a 64-slice CT scanner (Siemens Somatom Definition AS+) at University Malaya Medical Centre. A total of 120 patients were categorised into four age groups: G1 (0 - < 1 years), G2 (1 - < 5 years), G3 (5 - < 10 years), and G4 (10 - < 15 years). SSDE value was estimate in accordance with the American Association of Physicists, 2011 in Medicine (AAPM) report 204. The effective dose (E) and SSDENCICT obtained from National Cancer Institute Dosimetry System (NCICT) were then compared to the conventional SSDE value. The highest value of CTDIvol, DLP and E were found in group G4 with 4.9 +/- 2.5, 185.0 +/- 140.8, and 4.2 +/- 2.0, respectively. Moreover, there is only slightly different of SSDE value between the G1 and G2 groups with a factor of 0.91. No significant difference (p > 0.05) was observed between the SSDEAAPM and SSDENCICT across all age groups. The cancer risk estimated shows thyroid organs receives the highest probability of cancer incidence in both the genders, which was calculated to be 2.1 for males and 3.9 for females per 100,000 procedures, respectively. Nevertheless, adequate justification of paediatric CT scans and dose optimisation are required to reduce unnecessary exposure and radiation-induced risks.
format Article
author Karim, M. K. A.
Harun, H. H.
Kayun, Z.
Aljewaw, O. B.
Azizan, S. H. N.
Rafiz, N. F. N. M.
Muhammad, Norazura
author_facet Karim, M. K. A.
Harun, H. H.
Kayun, Z.
Aljewaw, O. B.
Azizan, S. H. N.
Rafiz, N. F. N. M.
Muhammad, Norazura
author_sort Karim, M. K. A.
title Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination
title_short Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination
title_full Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination
title_fullStr Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination
title_full_unstemmed Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination
title_sort paediatric radiation dose and cancer risk associated with body effective diameter during ct thorax examination
publisher Elsevier
publishDate 2021
url http://eprints.um.edu.my/28778/
_version_ 1744649137309089792
score 13.18916