Concentration measurement of opaque dye solution using a non-contact fiber displacement sensor

This paper reported the experimental and theoretical analysis of a non-contact fiber optics displacement sensor for the concentration measurement of opaque dye solution. This sensor was able to detect the concentration without having to dilute the opaque solution. Brilliant Blue FCF dye was used to...

Full description

Saved in:
Bibliographic Details
Main Authors: Krishnan, Ganesan, Abd Aziz, Muhammad Safwan, Abdullah, Mundzir, Harun, Sulaiman Wadi
Format: Article
Published: 2021
Subjects:
Online Access:http://eprints.um.edu.my/26302/
https://doi.org/10.1016/j.yofte.2021.102624
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.26302
record_format eprints
spelling my.um.eprints.263022022-02-22T01:19:00Z http://eprints.um.edu.my/26302/ Concentration measurement of opaque dye solution using a non-contact fiber displacement sensor Krishnan, Ganesan Abd Aziz, Muhammad Safwan Abdullah, Mundzir Harun, Sulaiman Wadi RE Ophthalmology TA Engineering (General). Civil engineering (General) This paper reported the experimental and theoretical analysis of a non-contact fiber optics displacement sensor for the concentration measurement of opaque dye solution. This sensor was able to detect the concentration without having to dilute the opaque solution. Brilliant Blue FCF dye was used to demonstrate the sensor. The displacement curves of dye solutions with various concentrations were taken using a white light source and a spectrometer as the detectors. The cumulative reflected powers (CRP) of the samples at various wavelengths were determined, and the simulated data were also in agreement. A unique transition wavelength was observed at 613.5 nm when the samples' CRP curve was compared with the water data. The sensing parameter was based on the total positive differences in the CRP results in a highly linear relationship over the dye concentration of 0.01 to 0.1 M. The sensitivity was measured at 4.7 x 108 a.u./M and the resolution was 2.0 mM. The proposed sensor had consistent performance, and the results were highly repeatable measurement with small variances. 2021-09 Article PeerReviewed Krishnan, Ganesan and Abd Aziz, Muhammad Safwan and Abdullah, Mundzir and Harun, Sulaiman Wadi (2021) Concentration measurement of opaque dye solution using a non-contact fiber displacement sensor. Optical Fiber Technology, 65. p. 102624. ISSN 10685200, DOI https://doi.org/10.1016/j.yofte.2021.102624 <https://doi.org/10.1016/j.yofte.2021.102624>. https://doi.org/10.1016/j.yofte.2021.102624 doi:10.1016/j.yofte.2021.102624
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic RE Ophthalmology
TA Engineering (General). Civil engineering (General)
spellingShingle RE Ophthalmology
TA Engineering (General). Civil engineering (General)
Krishnan, Ganesan
Abd Aziz, Muhammad Safwan
Abdullah, Mundzir
Harun, Sulaiman Wadi
Concentration measurement of opaque dye solution using a non-contact fiber displacement sensor
description This paper reported the experimental and theoretical analysis of a non-contact fiber optics displacement sensor for the concentration measurement of opaque dye solution. This sensor was able to detect the concentration without having to dilute the opaque solution. Brilliant Blue FCF dye was used to demonstrate the sensor. The displacement curves of dye solutions with various concentrations were taken using a white light source and a spectrometer as the detectors. The cumulative reflected powers (CRP) of the samples at various wavelengths were determined, and the simulated data were also in agreement. A unique transition wavelength was observed at 613.5 nm when the samples' CRP curve was compared with the water data. The sensing parameter was based on the total positive differences in the CRP results in a highly linear relationship over the dye concentration of 0.01 to 0.1 M. The sensitivity was measured at 4.7 x 108 a.u./M and the resolution was 2.0 mM. The proposed sensor had consistent performance, and the results were highly repeatable measurement with small variances.
format Article
author Krishnan, Ganesan
Abd Aziz, Muhammad Safwan
Abdullah, Mundzir
Harun, Sulaiman Wadi
author_facet Krishnan, Ganesan
Abd Aziz, Muhammad Safwan
Abdullah, Mundzir
Harun, Sulaiman Wadi
author_sort Krishnan, Ganesan
title Concentration measurement of opaque dye solution using a non-contact fiber displacement sensor
title_short Concentration measurement of opaque dye solution using a non-contact fiber displacement sensor
title_full Concentration measurement of opaque dye solution using a non-contact fiber displacement sensor
title_fullStr Concentration measurement of opaque dye solution using a non-contact fiber displacement sensor
title_full_unstemmed Concentration measurement of opaque dye solution using a non-contact fiber displacement sensor
title_sort concentration measurement of opaque dye solution using a non-contact fiber displacement sensor
publishDate 2021
url http://eprints.um.edu.my/26302/
https://doi.org/10.1016/j.yofte.2021.102624
_version_ 1735409397264285696
score 13.160551