Evaluation of organ dose and image quality metrics of pediatric CT chest-abdomen-pelvis (CAP) examination: An anthropomorphic phantom study

Featured Application We evaluate and propose a method for evaluating optimized CT protocol for pediatric-based figure of merit and image performance metrics. The aim of this study is to investigate the impact of CT acquisition parameter setting on organ dose and its influence on image quality...

Full description

Saved in:
Bibliographic Details
Main Authors: Muhammad, Nor Azura, Kayun, Zunaide, Abu Hassan, Hasyma, Wong, Jeannie Hsiu Ding, Ng, Kwan Hoong, Karim, Muhammad Khalis Abdul
Format: Article
Published: 2021
Subjects:
Online Access:http://eprints.um.edu.my/26281/
https://doi.org/10.3390/app11052047
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.26281
record_format eprints
spelling my.um.eprints.262812022-02-18T02:24:26Z http://eprints.um.edu.my/26281/ Evaluation of organ dose and image quality metrics of pediatric CT chest-abdomen-pelvis (CAP) examination: An anthropomorphic phantom study Muhammad, Nor Azura Kayun, Zunaide Abu Hassan, Hasyma Wong, Jeannie Hsiu Ding Ng, Kwan Hoong Karim, Muhammad Khalis Abdul Q Science (General) QC Physics QD Chemistry Featured Application We evaluate and propose a method for evaluating optimized CT protocol for pediatric-based figure of merit and image performance metrics. The aim of this study is to investigate the impact of CT acquisition parameter setting on organ dose and its influence on image quality metrics in pediatric phantom during CT examination. The study was performed on 64-slice multidetector CT scanner (MDCT) Siemens Definition AS (Siemens Sector Healthcare, Forchheim, Germany) using various CT CAP protocols (P1-P9). Tube potential for P1, P2, and P3 protocols were fixed at 100 kVp while P4, P5, and P6 were fixed at 80 kVp with used of various reference noise values. P7, P8, and P9 were the modification of P1 with changes on slice collimation, pitch factor, and tube current modulation (TCM), respectively. TLD-100 chips were inserted into the phantom slab number 7, 9, 10, 12, 13, and 14 to represent thyroid, lung, liver, stomach, gonads, and skin, respectively. The image quality metrics, signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were obtained from the CT console. As a result, this study indicates a potential reduction in the absorbed dose up to 20% to 50% along with reducing tube voltage, tube current, and increasing the slice collimation. There is no significant difference (p > 0.05) observed between the protocols and image metrics. 2021-03 Article PeerReviewed Muhammad, Nor Azura and Kayun, Zunaide and Abu Hassan, Hasyma and Wong, Jeannie Hsiu Ding and Ng, Kwan Hoong and Karim, Muhammad Khalis Abdul (2021) Evaluation of organ dose and image quality metrics of pediatric CT chest-abdomen-pelvis (CAP) examination: An anthropomorphic phantom study. Applied Sciences, 11 (5). p. 2047. ISSN 2076-3417, DOI https://doi.org/10.3390/app11052047 <https://doi.org/10.3390/app11052047>. https://doi.org/10.3390/app11052047 doi:10.3390/app11052047
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Q Science (General)
QC Physics
QD Chemistry
spellingShingle Q Science (General)
QC Physics
QD Chemistry
Muhammad, Nor Azura
Kayun, Zunaide
Abu Hassan, Hasyma
Wong, Jeannie Hsiu Ding
Ng, Kwan Hoong
Karim, Muhammad Khalis Abdul
Evaluation of organ dose and image quality metrics of pediatric CT chest-abdomen-pelvis (CAP) examination: An anthropomorphic phantom study
description Featured Application We evaluate and propose a method for evaluating optimized CT protocol for pediatric-based figure of merit and image performance metrics. The aim of this study is to investigate the impact of CT acquisition parameter setting on organ dose and its influence on image quality metrics in pediatric phantom during CT examination. The study was performed on 64-slice multidetector CT scanner (MDCT) Siemens Definition AS (Siemens Sector Healthcare, Forchheim, Germany) using various CT CAP protocols (P1-P9). Tube potential for P1, P2, and P3 protocols were fixed at 100 kVp while P4, P5, and P6 were fixed at 80 kVp with used of various reference noise values. P7, P8, and P9 were the modification of P1 with changes on slice collimation, pitch factor, and tube current modulation (TCM), respectively. TLD-100 chips were inserted into the phantom slab number 7, 9, 10, 12, 13, and 14 to represent thyroid, lung, liver, stomach, gonads, and skin, respectively. The image quality metrics, signal to noise ratio (SNR) and contrast to noise ratio (CNR) values were obtained from the CT console. As a result, this study indicates a potential reduction in the absorbed dose up to 20% to 50% along with reducing tube voltage, tube current, and increasing the slice collimation. There is no significant difference (p > 0.05) observed between the protocols and image metrics.
format Article
author Muhammad, Nor Azura
Kayun, Zunaide
Abu Hassan, Hasyma
Wong, Jeannie Hsiu Ding
Ng, Kwan Hoong
Karim, Muhammad Khalis Abdul
author_facet Muhammad, Nor Azura
Kayun, Zunaide
Abu Hassan, Hasyma
Wong, Jeannie Hsiu Ding
Ng, Kwan Hoong
Karim, Muhammad Khalis Abdul
author_sort Muhammad, Nor Azura
title Evaluation of organ dose and image quality metrics of pediatric CT chest-abdomen-pelvis (CAP) examination: An anthropomorphic phantom study
title_short Evaluation of organ dose and image quality metrics of pediatric CT chest-abdomen-pelvis (CAP) examination: An anthropomorphic phantom study
title_full Evaluation of organ dose and image quality metrics of pediatric CT chest-abdomen-pelvis (CAP) examination: An anthropomorphic phantom study
title_fullStr Evaluation of organ dose and image quality metrics of pediatric CT chest-abdomen-pelvis (CAP) examination: An anthropomorphic phantom study
title_full_unstemmed Evaluation of organ dose and image quality metrics of pediatric CT chest-abdomen-pelvis (CAP) examination: An anthropomorphic phantom study
title_sort evaluation of organ dose and image quality metrics of pediatric ct chest-abdomen-pelvis (cap) examination: an anthropomorphic phantom study
publishDate 2021
url http://eprints.um.edu.my/26281/
https://doi.org/10.3390/app11052047
_version_ 1735409394645991424
score 13.187197