Role of Composite Glycemic Indices: A Comparison of the Comprehensive Glucose Pentagon Across Diabetes Types and HbA1c Levels
Background: Complex changes of glycemia that occur in diabetes are not fully captured by any single measure. The Comprehensive Glucose Pentagon (CGP) measures multiple aspects of glycemia to generate the prognostic glycemic risk (PGR), which constitutes the relative risk of hypoglycemia combined wit...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Published: |
Mary Ann Liebert
2020
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/25344/ https://doi.org/10.1089/dia.2019.0277 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.25344 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.253442020-08-14T01:37:42Z http://eprints.um.edu.my/25344/ Role of Composite Glycemic Indices: A Comparison of the Comprehensive Glucose Pentagon Across Diabetes Types and HbA1c Levels Chandran, Suresh Rama Vigersky, Robert A. Thomas, Andreas Lim, Lee Ling Ratnasingam, Jeyakantha Tan, Alexander Gardner, Daphne S.L. R Medicine Background: Complex changes of glycemia that occur in diabetes are not fully captured by any single measure. The Comprehensive Glucose Pentagon (CGP) measures multiple aspects of glycemia to generate the prognostic glycemic risk (PGR), which constitutes the relative risk of hypoglycemia combined with long-term complications. We compare the components of CGP and PGR across type 1 and type 2 diabetes. Methods: Participants: n = 60 type 1 and n = 100 type 2 who underwent continuous glucose monitoring (CGM). Mean glucose, coefficient of variation (%CV), intensity of hypoglycemia (INThypo), intensity of hyperglycemia (INThyper), time out-of-range (TOR <3.9 and >10 mmol/L), and PGR were calculated. PGR (median, interquartile ranges [IQR]) for diabetes types, and HbA1c classes were compared. Results: While HbA1c was lower in type 1 (type 1 vs. type 2: 8.0 ± 1.6 vs. 8.6 ± 1.7, P = 0.02), CGM-derived mean glucoses were similar across both groups (P > 0.05). TOR, %CV, INThypo, and INThyper were all higher in type 1 [type 1 vs. type 2: 665 (500, 863) vs. 535 (284, 823) min/day; 39% (33, 46) vs. 29% (24, 34); 905 (205, 2951) vs. 18 (0, 349) mg/dL × min2; 42,906 (23,482, 82,120) vs. 30,166 (10,276, 57,183) mg/dL × min2, respectively, all P < 0.05]. Across each HbA1c class, the PGR remained consistently and significantly higher in type 1. While mean glucose remained the same across HbA1c classes, %CV, TOR, INThyper, and INThypo were significantly higher for type 1. Even within the same HbA1c class, the variation (IQR) of each parameter in type 1 was wider. The PGR increased across diabetes groups; type 2 on orals versus type 2 on insulin versus type 1 (PGR: 1.6 vs. 2.2 vs. 2.9, respectively, P < 0.05). Conclusion: Composite indices such as the CGP capture significant differences in glycemia independent of HbA1c and mean glucose. The use of such indices must be explored in both the clinical and research settings. © Copyright 2020, Mary Ann Liebert, Inc., publishers 2020. Mary Ann Liebert 2020 Article PeerReviewed Chandran, Suresh Rama and Vigersky, Robert A. and Thomas, Andreas and Lim, Lee Ling and Ratnasingam, Jeyakantha and Tan, Alexander and Gardner, Daphne S.L. (2020) Role of Composite Glycemic Indices: A Comparison of the Comprehensive Glucose Pentagon Across Diabetes Types and HbA1c Levels. Diabetes Technology & Therapeutics, 22 (2). pp. 103-111. ISSN 1520-9156 https://doi.org/10.1089/dia.2019.0277 doi:10.1089/dia.2019.0277 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
R Medicine |
spellingShingle |
R Medicine Chandran, Suresh Rama Vigersky, Robert A. Thomas, Andreas Lim, Lee Ling Ratnasingam, Jeyakantha Tan, Alexander Gardner, Daphne S.L. Role of Composite Glycemic Indices: A Comparison of the Comprehensive Glucose Pentagon Across Diabetes Types and HbA1c Levels |
description |
Background: Complex changes of glycemia that occur in diabetes are not fully captured by any single measure. The Comprehensive Glucose Pentagon (CGP) measures multiple aspects of glycemia to generate the prognostic glycemic risk (PGR), which constitutes the relative risk of hypoglycemia combined with long-term complications. We compare the components of CGP and PGR across type 1 and type 2 diabetes. Methods: Participants: n = 60 type 1 and n = 100 type 2 who underwent continuous glucose monitoring (CGM). Mean glucose, coefficient of variation (%CV), intensity of hypoglycemia (INThypo), intensity of hyperglycemia (INThyper), time out-of-range (TOR <3.9 and >10 mmol/L), and PGR were calculated. PGR (median, interquartile ranges [IQR]) for diabetes types, and HbA1c classes were compared. Results: While HbA1c was lower in type 1 (type 1 vs. type 2: 8.0 ± 1.6 vs. 8.6 ± 1.7, P = 0.02), CGM-derived mean glucoses were similar across both groups (P > 0.05). TOR, %CV, INThypo, and INThyper were all higher in type 1 [type 1 vs. type 2: 665 (500, 863) vs. 535 (284, 823) min/day; 39% (33, 46) vs. 29% (24, 34); 905 (205, 2951) vs. 18 (0, 349) mg/dL × min2; 42,906 (23,482, 82,120) vs. 30,166 (10,276, 57,183) mg/dL × min2, respectively, all P < 0.05]. Across each HbA1c class, the PGR remained consistently and significantly higher in type 1. While mean glucose remained the same across HbA1c classes, %CV, TOR, INThyper, and INThypo were significantly higher for type 1. Even within the same HbA1c class, the variation (IQR) of each parameter in type 1 was wider. The PGR increased across diabetes groups; type 2 on orals versus type 2 on insulin versus type 1 (PGR: 1.6 vs. 2.2 vs. 2.9, respectively, P < 0.05). Conclusion: Composite indices such as the CGP capture significant differences in glycemia independent of HbA1c and mean glucose. The use of such indices must be explored in both the clinical and research settings. © Copyright 2020, Mary Ann Liebert, Inc., publishers 2020. |
format |
Article |
author |
Chandran, Suresh Rama Vigersky, Robert A. Thomas, Andreas Lim, Lee Ling Ratnasingam, Jeyakantha Tan, Alexander Gardner, Daphne S.L. |
author_facet |
Chandran, Suresh Rama Vigersky, Robert A. Thomas, Andreas Lim, Lee Ling Ratnasingam, Jeyakantha Tan, Alexander Gardner, Daphne S.L. |
author_sort |
Chandran, Suresh Rama |
title |
Role of Composite Glycemic Indices: A Comparison of the Comprehensive Glucose Pentagon Across Diabetes Types and HbA1c Levels |
title_short |
Role of Composite Glycemic Indices: A Comparison of the Comprehensive Glucose Pentagon Across Diabetes Types and HbA1c Levels |
title_full |
Role of Composite Glycemic Indices: A Comparison of the Comprehensive Glucose Pentagon Across Diabetes Types and HbA1c Levels |
title_fullStr |
Role of Composite Glycemic Indices: A Comparison of the Comprehensive Glucose Pentagon Across Diabetes Types and HbA1c Levels |
title_full_unstemmed |
Role of Composite Glycemic Indices: A Comparison of the Comprehensive Glucose Pentagon Across Diabetes Types and HbA1c Levels |
title_sort |
role of composite glycemic indices: a comparison of the comprehensive glucose pentagon across diabetes types and hba1c levels |
publisher |
Mary Ann Liebert |
publishDate |
2020 |
url |
http://eprints.um.edu.my/25344/ https://doi.org/10.1089/dia.2019.0277 |
_version_ |
1680857021367189504 |
score |
13.211869 |