Determination of lonized calcium in serum with a calcium electrode
Using a calcium-sensitive electrode, the determination of ionic calcium in human serum was investigated. Serum samples obtained from 17 healthy individuals yielded the following data: total calcium 9.63 ± 1.11 mg 100 ml; ionized calcium 4.72 ± 0.61 mg 100 ml; and bound calcium, 4.91 ± 0.83 mg 100 ml...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Published: |
Elsevier
1970
|
Subjects: | |
Online Access: | http://eprints.um.edu.my/24582/ https://doi.org/10.1016/0006-2944(70)90003-7 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.um.eprints.24582 |
---|---|
record_format |
eprints |
spelling |
my.um.eprints.245822021-03-12T07:18:13Z http://eprints.um.edu.my/24582/ Determination of lonized calcium in serum with a calcium electrode Raman, A. R Medicine Using a calcium-sensitive electrode, the determination of ionic calcium in human serum was investigated. Serum samples obtained from 17 healthy individuals yielded the following data: total calcium 9.63 ± 1.11 mg 100 ml; ionized calcium 4.72 ± 0.61 mg 100 ml; and bound calcium, 4.91 ± 0.83 mg 100 ml. The proportion of ionized and bound calcium as a percentage of total calcium was 49.24 ± 5.08% and 50.76 ± 5.02%, respectively. It was concluded that the electrode method of measuring ionized calcium is probably the simplest and most practicable. © 1970. Elsevier 1970 Article PeerReviewed Raman, A. (1970) Determination of lonized calcium in serum with a calcium electrode. Biochemical Medicine, 3 (5). pp. 369-375. ISSN 0006-2944 https://doi.org/10.1016/0006-2944(70)90003-7 doi:10.1016/0006-2944(70)90003-7 |
institution |
Universiti Malaya |
building |
UM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Malaya |
content_source |
UM Research Repository |
url_provider |
http://eprints.um.edu.my/ |
topic |
R Medicine |
spellingShingle |
R Medicine Raman, A. Determination of lonized calcium in serum with a calcium electrode |
description |
Using a calcium-sensitive electrode, the determination of ionic calcium in human serum was investigated. Serum samples obtained from 17 healthy individuals yielded the following data: total calcium 9.63 ± 1.11 mg 100 ml; ionized calcium 4.72 ± 0.61 mg 100 ml; and bound calcium, 4.91 ± 0.83 mg 100 ml. The proportion of ionized and bound calcium as a percentage of total calcium was 49.24 ± 5.08% and 50.76 ± 5.02%, respectively. It was concluded that the electrode method of measuring ionized calcium is probably the simplest and most practicable. © 1970. |
format |
Article |
author |
Raman, A. |
author_facet |
Raman, A. |
author_sort |
Raman, A. |
title |
Determination of lonized calcium in serum with a calcium electrode |
title_short |
Determination of lonized calcium in serum with a calcium electrode |
title_full |
Determination of lonized calcium in serum with a calcium electrode |
title_fullStr |
Determination of lonized calcium in serum with a calcium electrode |
title_full_unstemmed |
Determination of lonized calcium in serum with a calcium electrode |
title_sort |
determination of lonized calcium in serum with a calcium electrode |
publisher |
Elsevier |
publishDate |
1970 |
url |
http://eprints.um.edu.my/24582/ https://doi.org/10.1016/0006-2944(70)90003-7 |
_version_ |
1695531091685801984 |
score |
13.214268 |