Transcatheter closure of patent ductus arteriosus: Our initial experience in University of Malaya Medical Centre

Six patients underwent transcatheter closure of patent ductus arteriosus (PDA) using either conventional Gianturco coils or the Amplatzer Ductal Occluder (ADO) device. All patients were females with a median age of 23.3 (range 4 to 26 years). The mean PDA size measured on the lateral aortogram was 3...

Full description

Saved in:
Bibliographic Details
Main Authors: Zain, Zarin Ikmal Zan, Wan Ahmad, Wan Azman, Omar, Asma, Alwi, Mazeni
Format: Article
Published: Faculty of Medicine, University of Malaya 2000
Subjects:
Online Access:http://eprints.um.edu.my/24397/
http://library.oum.edu.my/oumlib/node/586855
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.24397
record_format eprints
spelling my.um.eprints.243972020-06-01T02:56:32Z http://eprints.um.edu.my/24397/ Transcatheter closure of patent ductus arteriosus: Our initial experience in University of Malaya Medical Centre Zain, Zarin Ikmal Zan Wan Ahmad, Wan Azman Omar, Asma Alwi, Mazeni R Medicine Six patients underwent transcatheter closure of patent ductus arteriosus (PDA) using either conventional Gianturco coils or the Amplatzer Ductal Occluder (ADO) device. All patients were females with a median age of 23.3 (range 4 to 26 years). The mean PDA size measured on the lateral aortogram was 3.81mm (range 2.3-5.83mm). Complete closure of the PDA was achieved in all patients. Faculty of Medicine, University of Malaya 2000-06 Article PeerReviewed Zain, Zarin Ikmal Zan and Wan Ahmad, Wan Azman and Omar, Asma and Alwi, Mazeni (2000) Transcatheter closure of patent ductus arteriosus: Our initial experience in University of Malaya Medical Centre. Journal of the University of Malaya Medical Centre (JUMMEC), 5 (1). pp. 45-47. ISSN 1823-7339 http://library.oum.edu.my/oumlib/node/586855
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic R Medicine
spellingShingle R Medicine
Zain, Zarin Ikmal Zan
Wan Ahmad, Wan Azman
Omar, Asma
Alwi, Mazeni
Transcatheter closure of patent ductus arteriosus: Our initial experience in University of Malaya Medical Centre
description Six patients underwent transcatheter closure of patent ductus arteriosus (PDA) using either conventional Gianturco coils or the Amplatzer Ductal Occluder (ADO) device. All patients were females with a median age of 23.3 (range 4 to 26 years). The mean PDA size measured on the lateral aortogram was 3.81mm (range 2.3-5.83mm). Complete closure of the PDA was achieved in all patients.
format Article
author Zain, Zarin Ikmal Zan
Wan Ahmad, Wan Azman
Omar, Asma
Alwi, Mazeni
author_facet Zain, Zarin Ikmal Zan
Wan Ahmad, Wan Azman
Omar, Asma
Alwi, Mazeni
author_sort Zain, Zarin Ikmal Zan
title Transcatheter closure of patent ductus arteriosus: Our initial experience in University of Malaya Medical Centre
title_short Transcatheter closure of patent ductus arteriosus: Our initial experience in University of Malaya Medical Centre
title_full Transcatheter closure of patent ductus arteriosus: Our initial experience in University of Malaya Medical Centre
title_fullStr Transcatheter closure of patent ductus arteriosus: Our initial experience in University of Malaya Medical Centre
title_full_unstemmed Transcatheter closure of patent ductus arteriosus: Our initial experience in University of Malaya Medical Centre
title_sort transcatheter closure of patent ductus arteriosus: our initial experience in university of malaya medical centre
publisher Faculty of Medicine, University of Malaya
publishDate 2000
url http://eprints.um.edu.my/24397/
http://library.oum.edu.my/oumlib/node/586855
_version_ 1669007999112314880
score 13.160551