Selective harmonic elimination method for unequal DC sources of multilevel inverters

This paper presented an analytical and closed-form solution for the harmonic contents that were injected in the five-level inverters from asymmetrical DC sources or batteries which were suitable for renewable energy sources. In the five-level inverters, two DC sources V1 and V2 were used to synthesi...

Full description

Saved in:
Bibliographic Details
Main Authors: Ahmed, Mahrous, Orabi, Mohamed, Ghoneim, Sherif, Alharthi, Mosleh, Salem, Farhan, Alamri, Bassem, Mekhilef, Saad
Format: Article
Published: Taylor & Francis 2019
Subjects:
Online Access:http://eprints.um.edu.my/24365/
https://doi.org/10.1080/00051144.2019.1621048
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.24365
record_format eprints
spelling my.um.eprints.243652020-05-27T01:06:53Z http://eprints.um.edu.my/24365/ Selective harmonic elimination method for unequal DC sources of multilevel inverters Ahmed, Mahrous Orabi, Mohamed Ghoneim, Sherif Alharthi, Mosleh Salem, Farhan Alamri, Bassem Mekhilef, Saad TK Electrical engineering. Electronics Nuclear engineering This paper presented an analytical and closed-form solution for the harmonic contents that were injected in the five-level inverters from asymmetrical DC sources or batteries which were suitable for renewable energy sources. In the five-level inverters, two DC sources V1 and V2 were used to synthesize the output voltage. Therefore, two transcendental equations were formulated for the fundamental and the third harmonic orders based on the unequal DC sources V1 and V2. These transcendental equations were solved analytically for low switching control technique. The proposed solution included the modulation index change which resulted in changing the fundamental component. Therefore, two switching angles are formulated and solved analytically to control the amplitude of the fundamental voltage and cancel the third order harmonic. A well-known third order equation was generated. Thus, a closed-form solution for the above two switching angles will be generated in terms of the modulation index. The proposed solution was tested for a wide range of V1/V2 ratio. Some selected simulation and experimental results were provided to validate the proposed method for wide ranges of both modulation index and V1/V2 ratio. © 2019, © 2019 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group. Taylor & Francis 2019 Article PeerReviewed Ahmed, Mahrous and Orabi, Mohamed and Ghoneim, Sherif and Alharthi, Mosleh and Salem, Farhan and Alamri, Bassem and Mekhilef, Saad (2019) Selective harmonic elimination method for unequal DC sources of multilevel inverters. Automatika, 60 (4). pp. 378-384. ISSN 0005-1144 https://doi.org/10.1080/00051144.2019.1621048 doi:10.1080/00051144.2019.1621048
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Ahmed, Mahrous
Orabi, Mohamed
Ghoneim, Sherif
Alharthi, Mosleh
Salem, Farhan
Alamri, Bassem
Mekhilef, Saad
Selective harmonic elimination method for unequal DC sources of multilevel inverters
description This paper presented an analytical and closed-form solution for the harmonic contents that were injected in the five-level inverters from asymmetrical DC sources or batteries which were suitable for renewable energy sources. In the five-level inverters, two DC sources V1 and V2 were used to synthesize the output voltage. Therefore, two transcendental equations were formulated for the fundamental and the third harmonic orders based on the unequal DC sources V1 and V2. These transcendental equations were solved analytically for low switching control technique. The proposed solution included the modulation index change which resulted in changing the fundamental component. Therefore, two switching angles are formulated and solved analytically to control the amplitude of the fundamental voltage and cancel the third order harmonic. A well-known third order equation was generated. Thus, a closed-form solution for the above two switching angles will be generated in terms of the modulation index. The proposed solution was tested for a wide range of V1/V2 ratio. Some selected simulation and experimental results were provided to validate the proposed method for wide ranges of both modulation index and V1/V2 ratio. © 2019, © 2019 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.
format Article
author Ahmed, Mahrous
Orabi, Mohamed
Ghoneim, Sherif
Alharthi, Mosleh
Salem, Farhan
Alamri, Bassem
Mekhilef, Saad
author_facet Ahmed, Mahrous
Orabi, Mohamed
Ghoneim, Sherif
Alharthi, Mosleh
Salem, Farhan
Alamri, Bassem
Mekhilef, Saad
author_sort Ahmed, Mahrous
title Selective harmonic elimination method for unequal DC sources of multilevel inverters
title_short Selective harmonic elimination method for unequal DC sources of multilevel inverters
title_full Selective harmonic elimination method for unequal DC sources of multilevel inverters
title_fullStr Selective harmonic elimination method for unequal DC sources of multilevel inverters
title_full_unstemmed Selective harmonic elimination method for unequal DC sources of multilevel inverters
title_sort selective harmonic elimination method for unequal dc sources of multilevel inverters
publisher Taylor & Francis
publishDate 2019
url http://eprints.um.edu.my/24365/
https://doi.org/10.1080/00051144.2019.1621048
_version_ 1669007995907866624
score 13.160551