Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases

Infection of the hip after implant fixation is an uncommon yet devastating complication that results in poor long-term outcome. The gold standard treatment for chronic infection after hip arthroplasty is a two-stage protocol: eradication of infection, follow by re-implantation arthroplasty. The use...

Full description

Saved in:
Bibliographic Details
Main Authors: Choo, Ch'ng Hwei, Simmrat, Singh, Suhaeb, Abdulrazzaq Mahmod
Format: Article
Published: Malaysian Orthopaedic Association 2017
Subjects:
Online Access:http://eprints.um.edu.my/22805/
https://doi.org/10.5704/MOJ.1707.015
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.22805
record_format eprints
spelling my.um.eprints.228052019-10-22T04:13:58Z http://eprints.um.edu.my/22805/ Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases Choo, Ch'ng Hwei Simmrat, Singh Suhaeb, Abdulrazzaq Mahmod R Medicine Infection of the hip after implant fixation is an uncommon yet devastating complication that results in poor long-term outcome. The gold standard treatment for chronic infection after hip arthroplasty is a two-stage protocol: eradication of infection, follow by re-implantation arthroplasty. The use of interim antibiotic-laden cement spacer has become a popular procedure to maintain hip joint function and provide antibiotic elution simultaneously before re-implantation. However, antibiotic cement spacer is mechanically weak and breaks if overloaded. Therefore, we designed a cement mould with metallic endoskeleton with the aim of creating a stronger, inexpensive, antibiotic-impregnated spacer resembling a unipolar arthroplasty. We report two cases of severe hip joint infection after implant fixation (bipolar hemiarthroplasty, screw fixation neck of femur). Both patients had undergone first stage surgery of debridement and articulating antibiotic cement insertion using our design. Although the second stage surgery was planned for these patients, both patients delayed the operation in view of good functional status after a year walking with the antibiotic cement spacer. These cases showed that the mechanical property of the new antibiotic cement spacer was promising but further mechanical studies upon this new endoskeleton design are required. Malaysian Orthopaedic Association 2017 Article PeerReviewed Choo, Ch'ng Hwei and Simmrat, Singh and Suhaeb, Abdulrazzaq Mahmod (2017) Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases. Malaysian Orthopaedic Journal, 11 (2). pp. 78-81. ISSN 1985-2533 https://doi.org/10.5704/MOJ.1707.015 doi:10.5704/MOJ.1707.015
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic R Medicine
spellingShingle R Medicine
Choo, Ch'ng Hwei
Simmrat, Singh
Suhaeb, Abdulrazzaq Mahmod
Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
description Infection of the hip after implant fixation is an uncommon yet devastating complication that results in poor long-term outcome. The gold standard treatment for chronic infection after hip arthroplasty is a two-stage protocol: eradication of infection, follow by re-implantation arthroplasty. The use of interim antibiotic-laden cement spacer has become a popular procedure to maintain hip joint function and provide antibiotic elution simultaneously before re-implantation. However, antibiotic cement spacer is mechanically weak and breaks if overloaded. Therefore, we designed a cement mould with metallic endoskeleton with the aim of creating a stronger, inexpensive, antibiotic-impregnated spacer resembling a unipolar arthroplasty. We report two cases of severe hip joint infection after implant fixation (bipolar hemiarthroplasty, screw fixation neck of femur). Both patients had undergone first stage surgery of debridement and articulating antibiotic cement insertion using our design. Although the second stage surgery was planned for these patients, both patients delayed the operation in view of good functional status after a year walking with the antibiotic cement spacer. These cases showed that the mechanical property of the new antibiotic cement spacer was promising but further mechanical studies upon this new endoskeleton design are required.
format Article
author Choo, Ch'ng Hwei
Simmrat, Singh
Suhaeb, Abdulrazzaq Mahmod
author_facet Choo, Ch'ng Hwei
Simmrat, Singh
Suhaeb, Abdulrazzaq Mahmod
author_sort Choo, Ch'ng Hwei
title Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title_short Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title_full Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title_fullStr Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title_full_unstemmed Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title_sort cement mould and metallic endoskeleton for treatment of hip infection, an inexpensive alternative: a preliminary report of two cases
publisher Malaysian Orthopaedic Association
publishDate 2017
url http://eprints.um.edu.my/22805/
https://doi.org/10.5704/MOJ.1707.015
_version_ 1648736216303009792
score 13.214268