A comparison study for active chilled beam and variable air volume systems for an office building

Comparison in terms of energy and cost is carried out between two different air distribution systems, namely, Variable Air Volume (VAV) and Active Chilled Beam (ACB) based on a virtual building. The cooling load calculation was performed to determine the total load demand and the system design was c...

Full description

Saved in:
Bibliographic Details
Main Authors: Yau, Yat Huang, Tam, Jun Hao
Format: Article
Language:English
Published: Elsevier 2018
Subjects:
Online Access:http://eprints.um.edu.my/18883/1/A_comparison_study_for_active_chilled_beam_and_variable_air_volume_systems_for_an_office_building.pdf
http://eprints.um.edu.my/18883/
https://doi.org/10.1016/j.egypro.2018.09.160
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.18883
record_format eprints
spelling my.um.eprints.188832019-01-15T08:20:19Z http://eprints.um.edu.my/18883/ A comparison study for active chilled beam and variable air volume systems for an office building Yau, Yat Huang Tam, Jun Hao TA Engineering (General). Civil engineering (General) TJ Mechanical engineering and machinery Comparison in terms of energy and cost is carried out between two different air distribution systems, namely, Variable Air Volume (VAV) and Active Chilled Beam (ACB) based on a virtual building. The cooling load calculation was performed to determine the total load demand and the system design was carried out to determine the system capacity. Energy and cost analyses were carried out to determine which system gives the better saving. From the results analysis, it shows that the ACB is more energy-saving than the VAV, especially at full load and normal part-load conditions because of the reduced AHU fan’s capacity. In terms of cost, the ACB has a higher initial cost than the VAV where it is mainly contributed by the secondary chilled water pipe, heat exchanger and the beam itself. However, the operation cost is lower for ACB, and for long term use, the ACB is more cost-saving than the VAV. Elsevier 2018 Article PeerReviewed text en http://eprints.um.edu.my/18883/1/A_comparison_study_for_active_chilled_beam_and_variable_air_volume_systems_for_an_office_building.pdf Yau, Yat Huang and Tam, Jun Hao (2018) A comparison study for active chilled beam and variable air volume systems for an office building. Energy Procedia, 152. pp. 378-383. ISSN 1876-6102 https://doi.org/10.1016/j.egypro.2018.09.160 doi:10.1016/j.egypro.2018.09.160
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
language English
topic TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
spellingShingle TA Engineering (General). Civil engineering (General)
TJ Mechanical engineering and machinery
Yau, Yat Huang
Tam, Jun Hao
A comparison study for active chilled beam and variable air volume systems for an office building
description Comparison in terms of energy and cost is carried out between two different air distribution systems, namely, Variable Air Volume (VAV) and Active Chilled Beam (ACB) based on a virtual building. The cooling load calculation was performed to determine the total load demand and the system design was carried out to determine the system capacity. Energy and cost analyses were carried out to determine which system gives the better saving. From the results analysis, it shows that the ACB is more energy-saving than the VAV, especially at full load and normal part-load conditions because of the reduced AHU fan’s capacity. In terms of cost, the ACB has a higher initial cost than the VAV where it is mainly contributed by the secondary chilled water pipe, heat exchanger and the beam itself. However, the operation cost is lower for ACB, and for long term use, the ACB is more cost-saving than the VAV.
format Article
author Yau, Yat Huang
Tam, Jun Hao
author_facet Yau, Yat Huang
Tam, Jun Hao
author_sort Yau, Yat Huang
title A comparison study for active chilled beam and variable air volume systems for an office building
title_short A comparison study for active chilled beam and variable air volume systems for an office building
title_full A comparison study for active chilled beam and variable air volume systems for an office building
title_fullStr A comparison study for active chilled beam and variable air volume systems for an office building
title_full_unstemmed A comparison study for active chilled beam and variable air volume systems for an office building
title_sort comparison study for active chilled beam and variable air volume systems for an office building
publisher Elsevier
publishDate 2018
url http://eprints.um.edu.my/18883/1/A_comparison_study_for_active_chilled_beam_and_variable_air_volume_systems_for_an_office_building.pdf
http://eprints.um.edu.my/18883/
https://doi.org/10.1016/j.egypro.2018.09.160
_version_ 1643690824944320512
score 13.160551