A new under-voltage load shedding scheme for islanded distribution system based on voltage stability indices

Under-voltage load shedding (UVLS) is an important technique to maintain the voltage stability and frequency of a power system network. UVLS has been applied widely in transmission systems to avoid system blackouts. However, with increasing penetration of distributed generation such as photovoltaic...

Full description

Saved in:
Bibliographic Details
Main Authors: Yusof, N.A., Rosli, H.M., Mokhlis, Hazlie, Karimi, M., Selvaraj, Jeyraj, Sapari, N.M.
Format: Article
Published: Wiley 2017
Subjects:
Online Access:http://eprints.um.edu.my/18878/
http://dx.doi.org/10.1002/tee.22452
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.18878
record_format eprints
spelling my.um.eprints.188782019-10-10T02:40:50Z http://eprints.um.edu.my/18878/ A new under-voltage load shedding scheme for islanded distribution system based on voltage stability indices Yusof, N.A. Rosli, H.M. Mokhlis, Hazlie Karimi, M. Selvaraj, Jeyraj Sapari, N.M. TK Electrical engineering. Electronics Nuclear engineering Under-voltage load shedding (UVLS) is an important technique to maintain the voltage stability and frequency of a power system network. UVLS has been applied widely in transmission systems to avoid system blackouts. However, with increasing penetration of distributed generation such as photovoltaic (PV) systems, the application of UVLS becomes important for islanded distribution systems. Under this condition, the network does not have a frequency reference as when it is connected to the grid. In this condition, when the load demand exceeds the PV capacity, UVLS is the only option to stabilize the system by shedding the load based on the changes of the voltage magnitude. In this work, a new UVLS scheme based on voltage stability indices is proposed. Four voltage stability indices are used as indicators for load shedding. Based on the stability indices, the loads that have the highest tendency of voltage collapse shall be the first ones to be shed. The proposed scheme is tested on a practical distribution network energized by a grid, a mini hydro generator, and a PV system. The test results on various scenarios prove that the proposed method is able to restore the system stability. Wiley 2017 Article PeerReviewed Yusof, N.A. and Rosli, H.M. and Mokhlis, Hazlie and Karimi, M. and Selvaraj, Jeyraj and Sapari, N.M. (2017) A new under-voltage load shedding scheme for islanded distribution system based on voltage stability indices. IEEJ Transactions on Electrical and Electronic Engineering, 12 (5). pp. 665-675. ISSN 1931-4973 http://dx.doi.org/10.1002/tee.22452 doi:10.1002/tee.22452
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Yusof, N.A.
Rosli, H.M.
Mokhlis, Hazlie
Karimi, M.
Selvaraj, Jeyraj
Sapari, N.M.
A new under-voltage load shedding scheme for islanded distribution system based on voltage stability indices
description Under-voltage load shedding (UVLS) is an important technique to maintain the voltage stability and frequency of a power system network. UVLS has been applied widely in transmission systems to avoid system blackouts. However, with increasing penetration of distributed generation such as photovoltaic (PV) systems, the application of UVLS becomes important for islanded distribution systems. Under this condition, the network does not have a frequency reference as when it is connected to the grid. In this condition, when the load demand exceeds the PV capacity, UVLS is the only option to stabilize the system by shedding the load based on the changes of the voltage magnitude. In this work, a new UVLS scheme based on voltage stability indices is proposed. Four voltage stability indices are used as indicators for load shedding. Based on the stability indices, the loads that have the highest tendency of voltage collapse shall be the first ones to be shed. The proposed scheme is tested on a practical distribution network energized by a grid, a mini hydro generator, and a PV system. The test results on various scenarios prove that the proposed method is able to restore the system stability.
format Article
author Yusof, N.A.
Rosli, H.M.
Mokhlis, Hazlie
Karimi, M.
Selvaraj, Jeyraj
Sapari, N.M.
author_facet Yusof, N.A.
Rosli, H.M.
Mokhlis, Hazlie
Karimi, M.
Selvaraj, Jeyraj
Sapari, N.M.
author_sort Yusof, N.A.
title A new under-voltage load shedding scheme for islanded distribution system based on voltage stability indices
title_short A new under-voltage load shedding scheme for islanded distribution system based on voltage stability indices
title_full A new under-voltage load shedding scheme for islanded distribution system based on voltage stability indices
title_fullStr A new under-voltage load shedding scheme for islanded distribution system based on voltage stability indices
title_full_unstemmed A new under-voltage load shedding scheme for islanded distribution system based on voltage stability indices
title_sort new under-voltage load shedding scheme for islanded distribution system based on voltage stability indices
publisher Wiley
publishDate 2017
url http://eprints.um.edu.my/18878/
http://dx.doi.org/10.1002/tee.22452
_version_ 1648736154676101120
score 13.214268