Is the Femoral Neck Geometry Adequate for Placement of the Proximal Femoral Nail in the Malaysian Population?

Issues that had been encountered during proximal femoral fracture fixation using proximal femoral nail include i) the adequacy of the femoral neck width in the local population and ii) the potential difficulty encountered during fixation in certain prefixed angles as determined by the implant. This...

Full description

Saved in:
Bibliographic Details
Main Authors: Chiu, C.K., Chan, C.Y.W., Singh, V.A.
Format: Article
Published: Malaysian Medical Association 2009
Subjects:
Online Access:http://eprints.um.edu.my/1705/
http://myais.fsktm.um.edu.my/10098/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.1705
record_format eprints
spelling my.um.eprints.17052019-12-06T06:07:03Z http://eprints.um.edu.my/1705/ Is the Femoral Neck Geometry Adequate for Placement of the Proximal Femoral Nail in the Malaysian Population? Chiu, C.K. Chan, C.Y.W. Singh, V.A. R Medicine Issues that had been encountered during proximal femoral fracture fixation using proximal femoral nail include i) the adequacy of the femoral neck width in the local population and ii) the potential difficulty encountered during fixation in certain prefixed angles as determined by the implant. This was a retrospective, descriptive study evaluating the anterior-posterior pelvic radiographs of 100 consecutive patients, from January to August 2007, managed at University Malaya Medical Centre, Kuala Lumpur. The femoral neck width in the population studied was adequate for placement of femoral neck screw and anti-rotation pin or hip pin using the proximal femoral nail implant. (mean = 34.0±3.7mm, min = 24.6mm). There was no significant difference between the working area using an implant angled at 130° or 135° (P=0.91). Both femoral neck width and neck shaft angle of the Malaysian population studied were not a factor influencing the placement of femoral neck lag screws and anti-rotation pin. Malaysian Medical Association 2009 Article PeerReviewed Chiu, C.K. and Chan, C.Y.W. and Singh, V.A. (2009) Is the Femoral Neck Geometry Adequate for Placement of the Proximal Femoral Nail in the Malaysian Population? Medical Journal of Malaysia, 64 (1). pp. 22-26. ISSN 0300-5283 http://myais.fsktm.um.edu.my/10098/ 10098
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic R Medicine
spellingShingle R Medicine
Chiu, C.K.
Chan, C.Y.W.
Singh, V.A.
Is the Femoral Neck Geometry Adequate for Placement of the Proximal Femoral Nail in the Malaysian Population?
description Issues that had been encountered during proximal femoral fracture fixation using proximal femoral nail include i) the adequacy of the femoral neck width in the local population and ii) the potential difficulty encountered during fixation in certain prefixed angles as determined by the implant. This was a retrospective, descriptive study evaluating the anterior-posterior pelvic radiographs of 100 consecutive patients, from January to August 2007, managed at University Malaya Medical Centre, Kuala Lumpur. The femoral neck width in the population studied was adequate for placement of femoral neck screw and anti-rotation pin or hip pin using the proximal femoral nail implant. (mean = 34.0±3.7mm, min = 24.6mm). There was no significant difference between the working area using an implant angled at 130° or 135° (P=0.91). Both femoral neck width and neck shaft angle of the Malaysian population studied were not a factor influencing the placement of femoral neck lag screws and anti-rotation pin.
format Article
author Chiu, C.K.
Chan, C.Y.W.
Singh, V.A.
author_facet Chiu, C.K.
Chan, C.Y.W.
Singh, V.A.
author_sort Chiu, C.K.
title Is the Femoral Neck Geometry Adequate for Placement of the Proximal Femoral Nail in the Malaysian Population?
title_short Is the Femoral Neck Geometry Adequate for Placement of the Proximal Femoral Nail in the Malaysian Population?
title_full Is the Femoral Neck Geometry Adequate for Placement of the Proximal Femoral Nail in the Malaysian Population?
title_fullStr Is the Femoral Neck Geometry Adequate for Placement of the Proximal Femoral Nail in the Malaysian Population?
title_full_unstemmed Is the Femoral Neck Geometry Adequate for Placement of the Proximal Femoral Nail in the Malaysian Population?
title_sort is the femoral neck geometry adequate for placement of the proximal femoral nail in the malaysian population?
publisher Malaysian Medical Association
publishDate 2009
url http://eprints.um.edu.my/1705/
http://myais.fsktm.um.edu.my/10098/
_version_ 1654960580554915840
score 13.159267