Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers

Recently, surface enhanced Raman scattering (SERS) has attracted much attention in medical diagnosis applications owing to better detection sensitivity and lower limit of detection (LOD) than colorimetric detection. In this paper, a novel calibration-free SERS−based μPAD with multi-reaction zones fo...

Full description

Saved in:
Bibliographic Details
Main Authors: Lim, Wei Yin, Goh, Choon Hian, Thevarajah, T. Malathi, Goh, Boon Tong, Khor, Sook Mei
Format: Article
Published: Elsevier 2020
Subjects:
Online Access:http://eprints.um.edu.my/14767/
https://doi.org/10.1016/j.bios.2019.111792
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.14767
record_format eprints
spelling my.um.eprints.147672019-11-11T04:45:27Z http://eprints.um.edu.my/14767/ Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers Lim, Wei Yin Goh, Choon Hian Thevarajah, T. Malathi Goh, Boon Tong Khor, Sook Mei QC Physics QD Chemistry R Medicine Recently, surface enhanced Raman scattering (SERS) has attracted much attention in medical diagnosis applications owing to better detection sensitivity and lower limit of detection (LOD) than colorimetric detection. In this paper, a novel calibration-free SERS−based μPAD with multi-reaction zones for simultaneous quantitative detection of multiple cardiac biomarkers — GPBB, CK−MB and cTnT for early diagnosis and prognosis of acute myocardial infarction (AMI) are presented. Three distinct Raman probes were synthesised, subsequently conjugated with respective detecting antibodies and used as SERS nanotags for cardiac biomarker detection. Using a conventional calibration curve, quantitative simultaneous measurement of multiple cardiac biomarkers on SERS-based μPAD was performed based on the characteristic Raman spectral features of each reporter used in different nanotags. However, a calibration free point-of-care testing device is required for fast screening to rule-in and rule-out AMI patients. Partial least squares predictive models were developed and incorporated into the immunosensing system, to accurately quantify the three unknown cardiac biomarkers levels in serum based on the previously obtained Raman spectral data. This method allows absolute quantitative measurement when conventional calibration curve fails to provide accurate estimation of cardiac biomarkers, especially at low and high concentration ranges. Under an optimised condition, the LOD of our SERS-based μPAD was identified at 8, 10, and 1 pg mL−1, for GPBB, CK−MB and cTnT, respectively, which is well below the clinical cutoff values. Therefore, this proof-of-concept technique shows significant potential for highly sensitive quantitative detection of multiplex cardiac biomarkers in human serum to expedite medical decisions for enhanced patient care. © 2019 Elsevier B.V. Elsevier 2020 Article PeerReviewed Lim, Wei Yin and Goh, Choon Hian and Thevarajah, T. Malathi and Goh, Boon Tong and Khor, Sook Mei (2020) Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers. Biosensors and Bioelectronics, 147. p. 111792. ISSN 0956-5663 https://doi.org/10.1016/j.bios.2019.111792 doi:10.1016/j.bios.2019.111792
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic QC Physics
QD Chemistry
R Medicine
spellingShingle QC Physics
QD Chemistry
R Medicine
Lim, Wei Yin
Goh, Choon Hian
Thevarajah, T. Malathi
Goh, Boon Tong
Khor, Sook Mei
Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers
description Recently, surface enhanced Raman scattering (SERS) has attracted much attention in medical diagnosis applications owing to better detection sensitivity and lower limit of detection (LOD) than colorimetric detection. In this paper, a novel calibration-free SERS−based μPAD with multi-reaction zones for simultaneous quantitative detection of multiple cardiac biomarkers — GPBB, CK−MB and cTnT for early diagnosis and prognosis of acute myocardial infarction (AMI) are presented. Three distinct Raman probes were synthesised, subsequently conjugated with respective detecting antibodies and used as SERS nanotags for cardiac biomarker detection. Using a conventional calibration curve, quantitative simultaneous measurement of multiple cardiac biomarkers on SERS-based μPAD was performed based on the characteristic Raman spectral features of each reporter used in different nanotags. However, a calibration free point-of-care testing device is required for fast screening to rule-in and rule-out AMI patients. Partial least squares predictive models were developed and incorporated into the immunosensing system, to accurately quantify the three unknown cardiac biomarkers levels in serum based on the previously obtained Raman spectral data. This method allows absolute quantitative measurement when conventional calibration curve fails to provide accurate estimation of cardiac biomarkers, especially at low and high concentration ranges. Under an optimised condition, the LOD of our SERS-based μPAD was identified at 8, 10, and 1 pg mL−1, for GPBB, CK−MB and cTnT, respectively, which is well below the clinical cutoff values. Therefore, this proof-of-concept technique shows significant potential for highly sensitive quantitative detection of multiplex cardiac biomarkers in human serum to expedite medical decisions for enhanced patient care. © 2019 Elsevier B.V.
format Article
author Lim, Wei Yin
Goh, Choon Hian
Thevarajah, T. Malathi
Goh, Boon Tong
Khor, Sook Mei
author_facet Lim, Wei Yin
Goh, Choon Hian
Thevarajah, T. Malathi
Goh, Boon Tong
Khor, Sook Mei
author_sort Lim, Wei Yin
title Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers
title_short Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers
title_full Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers
title_fullStr Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers
title_full_unstemmed Using SERS-based microfluidic paper-based device (μPAD) for calibration-free quantitative measurement of AMI cardiac biomarkers
title_sort using sers-based microfluidic paper-based device (μpad) for calibration-free quantitative measurement of ami cardiac biomarkers
publisher Elsevier
publishDate 2020
url http://eprints.um.edu.my/14767/
https://doi.org/10.1016/j.bios.2019.111792
_version_ 1651867364776476672
score 13.160551