Tapered Plastic Optical Fiber Coated With HEC/PVDF for Measurement of Relative Humidity

A simple humidity sensor is proposed and demonstrated using a tapered plastic optical fiber (POF) as a probe. Its operation is based on intensity modulation technique using a tapered POF probe coated with a polymer blend of hydroxyethylcellulose/polyvinylidenefluoride (HEC/PVDF) composite that acts...

Full description

Saved in:
Bibliographic Details
Main Authors: Batumalay, Malathy, Lokman, A., Ahmad, F., Arof, Hamzah, Ahmad, Harith, Harun, Sulaiman Wadi
Format: Article
Published: Institute of Electrical and Electronics Engineers (IEEE) 2013
Subjects:
Online Access:http://eprints.um.edu.my/14388/
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6552979
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.14388
record_format eprints
spelling my.um.eprints.143882018-10-09T05:34:42Z http://eprints.um.edu.my/14388/ Tapered Plastic Optical Fiber Coated With HEC/PVDF for Measurement of Relative Humidity Batumalay, Malathy Lokman, A. Ahmad, F. Arof, Hamzah Ahmad, Harith Harun, Sulaiman Wadi QC Physics TK Electrical engineering. Electronics Nuclear engineering A simple humidity sensor is proposed and demonstrated using a tapered plastic optical fiber (POF) as a probe. Its operation is based on intensity modulation technique using a tapered POF probe coated with a polymer blend of hydroxyethylcellulose/polyvinylidenefluoride (HEC/PVDF) composite that acts as the humidity sensitive cladding. The sensor is fabricated using an etching method and has a waist diameter of 0.45 mm and tapering length of 10 mm. As the relative humidity varies from 50% to 85%, the output voltage of the sensor increases linearly from 0.32 to 1.25 mV. The HEC/PVDF composite-coated sensor exhibits a sensitivity of 0.023 mV/% with a slope linearity of . The sensitivity of HEC/PVDF composite-coated cladding toward humidity stems from its ability to swell as humidity increases in the atmosphere resulting in a drop in its refractive index below that of the core and thus allowing more light to be transmitted through the tapered fiber. Institute of Electrical and Electronics Engineers (IEEE) 2013-07-03 Article PeerReviewed Batumalay, Malathy and Lokman, A. and Ahmad, F. and Arof, Hamzah and Ahmad, Harith and Harun, Sulaiman Wadi (2013) Tapered Plastic Optical Fiber Coated With HEC/PVDF for Measurement of Relative Humidity. IEEE Sensors Journal, 13 (12). pp. 4702-4705. ISSN 1530-437X http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6552979 DOI:10.1109/JSEN.2013.2272329
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic QC Physics
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle QC Physics
TK Electrical engineering. Electronics Nuclear engineering
Batumalay, Malathy
Lokman, A.
Ahmad, F.
Arof, Hamzah
Ahmad, Harith
Harun, Sulaiman Wadi
Tapered Plastic Optical Fiber Coated With HEC/PVDF for Measurement of Relative Humidity
description A simple humidity sensor is proposed and demonstrated using a tapered plastic optical fiber (POF) as a probe. Its operation is based on intensity modulation technique using a tapered POF probe coated with a polymer blend of hydroxyethylcellulose/polyvinylidenefluoride (HEC/PVDF) composite that acts as the humidity sensitive cladding. The sensor is fabricated using an etching method and has a waist diameter of 0.45 mm and tapering length of 10 mm. As the relative humidity varies from 50% to 85%, the output voltage of the sensor increases linearly from 0.32 to 1.25 mV. The HEC/PVDF composite-coated sensor exhibits a sensitivity of 0.023 mV/% with a slope linearity of . The sensitivity of HEC/PVDF composite-coated cladding toward humidity stems from its ability to swell as humidity increases in the atmosphere resulting in a drop in its refractive index below that of the core and thus allowing more light to be transmitted through the tapered fiber.
format Article
author Batumalay, Malathy
Lokman, A.
Ahmad, F.
Arof, Hamzah
Ahmad, Harith
Harun, Sulaiman Wadi
author_facet Batumalay, Malathy
Lokman, A.
Ahmad, F.
Arof, Hamzah
Ahmad, Harith
Harun, Sulaiman Wadi
author_sort Batumalay, Malathy
title Tapered Plastic Optical Fiber Coated With HEC/PVDF for Measurement of Relative Humidity
title_short Tapered Plastic Optical Fiber Coated With HEC/PVDF for Measurement of Relative Humidity
title_full Tapered Plastic Optical Fiber Coated With HEC/PVDF for Measurement of Relative Humidity
title_fullStr Tapered Plastic Optical Fiber Coated With HEC/PVDF for Measurement of Relative Humidity
title_full_unstemmed Tapered Plastic Optical Fiber Coated With HEC/PVDF for Measurement of Relative Humidity
title_sort tapered plastic optical fiber coated with hec/pvdf for measurement of relative humidity
publisher Institute of Electrical and Electronics Engineers (IEEE)
publishDate 2013
url http://eprints.um.edu.my/14388/
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6552979
_version_ 1643689801593913344
score 13.250246