Tapered Plastic Optical Fiber Coated With HEC/PVDF for Measurement of Relative Humidity
A simple humidity sensor is proposed and demonstrated using a tapered plastic optical fiber (POF) as a probe. Its operation is based on intensity modulation technique using a tapered POF probe coated with a polymer blend of hydroxyethylcellulose/polyvinylidenefluoride (HEC/PVDF) composite that acts...
保存先:
主要な著者: | , , , , , |
---|---|
フォーマット: | 論文 |
出版事項: |
Institute of Electrical and Electronics Engineers (IEEE)
2013
|
主題: | |
オンライン・アクセス: | http://eprints.um.edu.my/14388/ http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6552979 |
タグ: |
タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
|
要約: | A simple humidity sensor is proposed and demonstrated using a tapered plastic optical fiber (POF) as a probe. Its operation is based on intensity modulation technique using a tapered POF probe coated with a polymer blend of hydroxyethylcellulose/polyvinylidenefluoride (HEC/PVDF) composite that acts as the humidity sensitive cladding. The sensor is fabricated using an etching method and has a waist diameter of 0.45 mm and tapering length of 10 mm. As the relative humidity varies from 50% to 85%, the output voltage of the sensor increases linearly from 0.32 to 1.25 mV. The HEC/PVDF composite-coated sensor exhibits a sensitivity of 0.023 mV/% with a slope linearity of . The sensitivity of HEC/PVDF composite-coated cladding toward humidity stems from its ability to swell as humidity increases in the atmosphere resulting in a drop in its refractive index below that of the core and thus allowing more light to be transmitted through the tapered fiber. |
---|