The spatial distribution of carbon dioxide in an environmental test chamber

The spatial distribution of CO(2) level in a classroom carried out in previous field work research has demonstrated that there is some evidence of variations in CO(2) concentration in a classroom space. Significant fluctuations in CO(2) concentration were found at different sampling points depending...

Full description

Saved in:
Bibliographic Details
Main Authors: Mahyuddin, N., Awbi, H.
Format: Article
Published: Elsevier 2010
Subjects:
Online Access:http://eprints.um.edu.my/12424/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.12424
record_format eprints
spelling my.um.eprints.124242015-01-28T03:30:16Z http://eprints.um.edu.my/12424/ The spatial distribution of carbon dioxide in an environmental test chamber Mahyuddin, N. Awbi, H. Q Science (General) The spatial distribution of CO(2) level in a classroom carried out in previous field work research has demonstrated that there is some evidence of variations in CO(2) concentration in a classroom space. Significant fluctuations in CO(2) concentration were found at different sampling points depending on the ventilation strategies and environmental conditions prevailing in individual classrooms. However, how these variations are affected by the emitting sources and the room air movement remains unknown. Hence, it was concluded that detailed investigation of the CO(2) distribution need to be performed on a smaller scale. As a result, it was decided to use an environmental chamber with various methods and rates of ventilation, for the same internal temperature and heat loads, to study the effect of ventilation strategy and air movement on the distribution of CO(2) concentration in a room. The role of human exhalation and its interaction with the plume induced by the body's convective flow and room air movement due to different ventilation strategies were studied in a chamber at the University of Reading. These phenomena are considered to be important in understanding and predicting the flow patterns in a space and how these impact on the distribution of contaminants. This paper attempts to study the CO(2) dispersion and distribution at the exhalation zone of two people sitting in a chamber as well as throughout the occupied zone of the chamber. The horizontal and vertical distributions of CO(2) were sampled at locations with a probability that CO(2) variation is considered high. Although the room size, source location, ventilation rate and location of air supply and extract devices all can have influence on the CO(2) distribution, this article gives general guidelines on the optimum positioning of CO(2) sensor in a room. (C) 2010 Elsevier Ltd. All rights reserved. Elsevier 2010 Article PeerReviewed Mahyuddin, N. and Awbi, H. (2010) The spatial distribution of carbon dioxide in an environmental test chamber. Building and Environment, 45 (9, SI). pp. 1993-2001.
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Q Science (General)
spellingShingle Q Science (General)
Mahyuddin, N.
Awbi, H.
The spatial distribution of carbon dioxide in an environmental test chamber
description The spatial distribution of CO(2) level in a classroom carried out in previous field work research has demonstrated that there is some evidence of variations in CO(2) concentration in a classroom space. Significant fluctuations in CO(2) concentration were found at different sampling points depending on the ventilation strategies and environmental conditions prevailing in individual classrooms. However, how these variations are affected by the emitting sources and the room air movement remains unknown. Hence, it was concluded that detailed investigation of the CO(2) distribution need to be performed on a smaller scale. As a result, it was decided to use an environmental chamber with various methods and rates of ventilation, for the same internal temperature and heat loads, to study the effect of ventilation strategy and air movement on the distribution of CO(2) concentration in a room. The role of human exhalation and its interaction with the plume induced by the body's convective flow and room air movement due to different ventilation strategies were studied in a chamber at the University of Reading. These phenomena are considered to be important in understanding and predicting the flow patterns in a space and how these impact on the distribution of contaminants. This paper attempts to study the CO(2) dispersion and distribution at the exhalation zone of two people sitting in a chamber as well as throughout the occupied zone of the chamber. The horizontal and vertical distributions of CO(2) were sampled at locations with a probability that CO(2) variation is considered high. Although the room size, source location, ventilation rate and location of air supply and extract devices all can have influence on the CO(2) distribution, this article gives general guidelines on the optimum positioning of CO(2) sensor in a room. (C) 2010 Elsevier Ltd. All rights reserved.
format Article
author Mahyuddin, N.
Awbi, H.
author_facet Mahyuddin, N.
Awbi, H.
author_sort Mahyuddin, N.
title The spatial distribution of carbon dioxide in an environmental test chamber
title_short The spatial distribution of carbon dioxide in an environmental test chamber
title_full The spatial distribution of carbon dioxide in an environmental test chamber
title_fullStr The spatial distribution of carbon dioxide in an environmental test chamber
title_full_unstemmed The spatial distribution of carbon dioxide in an environmental test chamber
title_sort spatial distribution of carbon dioxide in an environmental test chamber
publisher Elsevier
publishDate 2010
url http://eprints.um.edu.my/12424/
_version_ 1643689294673477632
score 13.211869