Parametric investigation on an off-centre braced frame system's stiffness

In this paper, a particular off-centre braced (OCB) system subjected to lateral load, which induced compressive force to the brace elements is examined. This bracing system consists of three members, where the diagonal member is not straight and it is connected to the corner of the frame by a third...

Full description

Saved in:
Bibliographic Details
Main Authors: Mosalman, H., Sulong, No.R.
Format: Article
Published: Academic Journals 2010
Subjects:
Online Access:http://eprints.um.edu.my/11662/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.11662
record_format eprints
spelling my.um.eprints.116622019-03-20T08:34:28Z http://eprints.um.edu.my/11662/ Parametric investigation on an off-centre braced frame system's stiffness Mosalman, H. Sulong, No.R. Q Science (General) In this paper, a particular off-centre braced (OCB) system subjected to lateral load, which induced compressive force to the brace elements is examined. This bracing system consists of three members, where the diagonal member is not straight and it is connected to the corner of the frame by a third member. The out-of-straightness of the diagonal members will introduce eccentricity to the system. This system improves the energy dissipation due to earthquake as well as its eccentricity allows architects to have more openings in the panel areas. In this regard, the location of connection point of the three braced elements that is the eccentricity, considering the opening dimensions has significant effect on the stiffness of the system. In order to assess the influence of the connection position and other parameters such as cross-section area of the brace elements and span/ height ratio of the frame on the stiffness of the system, analytical studies to obtain the stiffness equations have been developed. The results indicate that as the eccentricity increasing (connection point moves closer to the corner of the frame), the frame's stiffness decreases. Also, the cross-section area of the third member has a significant role on the stiffness of this system and can make up the stiffness elimination due to increasing eccentricity of the connection point. In addition, a range of values in locating the brace elements connection point is introduced, which could be helpful for designers. Academic Journals 2010 Article PeerReviewed Mosalman, H. and Sulong, No.R. (2010) Parametric investigation on an off-centre braced frame system's stiffness. International Journal of the Physical Sciences, 5 (17). pp. 2642-2651. ISSN 1992-1950
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Q Science (General)
spellingShingle Q Science (General)
Mosalman, H.
Sulong, No.R.
Parametric investigation on an off-centre braced frame system's stiffness
description In this paper, a particular off-centre braced (OCB) system subjected to lateral load, which induced compressive force to the brace elements is examined. This bracing system consists of three members, where the diagonal member is not straight and it is connected to the corner of the frame by a third member. The out-of-straightness of the diagonal members will introduce eccentricity to the system. This system improves the energy dissipation due to earthquake as well as its eccentricity allows architects to have more openings in the panel areas. In this regard, the location of connection point of the three braced elements that is the eccentricity, considering the opening dimensions has significant effect on the stiffness of the system. In order to assess the influence of the connection position and other parameters such as cross-section area of the brace elements and span/ height ratio of the frame on the stiffness of the system, analytical studies to obtain the stiffness equations have been developed. The results indicate that as the eccentricity increasing (connection point moves closer to the corner of the frame), the frame's stiffness decreases. Also, the cross-section area of the third member has a significant role on the stiffness of this system and can make up the stiffness elimination due to increasing eccentricity of the connection point. In addition, a range of values in locating the brace elements connection point is introduced, which could be helpful for designers.
format Article
author Mosalman, H.
Sulong, No.R.
author_facet Mosalman, H.
Sulong, No.R.
author_sort Mosalman, H.
title Parametric investigation on an off-centre braced frame system's stiffness
title_short Parametric investigation on an off-centre braced frame system's stiffness
title_full Parametric investigation on an off-centre braced frame system's stiffness
title_fullStr Parametric investigation on an off-centre braced frame system's stiffness
title_full_unstemmed Parametric investigation on an off-centre braced frame system's stiffness
title_sort parametric investigation on an off-centre braced frame system's stiffness
publisher Academic Journals
publishDate 2010
url http://eprints.um.edu.my/11662/
_version_ 1643689109888172032
score 13.211869