Performance analysis of a heat pipe heat exchanger under different fluid charges

An experimental study was conducted on the effects of the amount of working fluid on the performance of a two-row copper-R134a heat pipe heat exchanger at the air side. The heat pipe heat exchanger operates in the horizontal configuration, and five different fluid charges were studied to cover the u...

Full description

Saved in:
Bibliographic Details
Main Authors: Yau, Y.H., Ahmadzadehtalatapeh, M.
Format: Article
Published: Taylor & Francis 2014
Subjects:
Online Access:http://eprints.um.edu.my/11647/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.um.eprints.11647
record_format eprints
spelling my.um.eprints.116472015-01-06T02:10:30Z http://eprints.um.edu.my/11647/ Performance analysis of a heat pipe heat exchanger under different fluid charges Yau, Y.H. Ahmadzadehtalatapeh, M. Q Science (General) An experimental study was conducted on the effects of the amount of working fluid on the performance of a two-row copper-R134a heat pipe heat exchanger at the air side. The heat pipe heat exchanger operates in the horizontal configuration, and five different fluid charges were studied to cover the underload and overload cases. Moreover, the calculated outlet temperature of the evaporator side, obtained from the heat exchanger simulation, was compared with the experimental results. Based on the present study, it was found that the optimum performance of the copper-R134a heat pipe heat exchanger can be achieved at a fluid charge slightly exceeding the amount required to saturate the wick. Taylor & Francis 2014 Article PeerReviewed Yau, Y.H. and Ahmadzadehtalatapeh, M. (2014) Performance analysis of a heat pipe heat exchanger under different fluid charges. Heat Transfer Engineering, 35 (18). pp. 1539-1548. ISSN 0145-7632
institution Universiti Malaya
building UM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Malaya
content_source UM Research Repository
url_provider http://eprints.um.edu.my/
topic Q Science (General)
spellingShingle Q Science (General)
Yau, Y.H.
Ahmadzadehtalatapeh, M.
Performance analysis of a heat pipe heat exchanger under different fluid charges
description An experimental study was conducted on the effects of the amount of working fluid on the performance of a two-row copper-R134a heat pipe heat exchanger at the air side. The heat pipe heat exchanger operates in the horizontal configuration, and five different fluid charges were studied to cover the underload and overload cases. Moreover, the calculated outlet temperature of the evaporator side, obtained from the heat exchanger simulation, was compared with the experimental results. Based on the present study, it was found that the optimum performance of the copper-R134a heat pipe heat exchanger can be achieved at a fluid charge slightly exceeding the amount required to saturate the wick.
format Article
author Yau, Y.H.
Ahmadzadehtalatapeh, M.
author_facet Yau, Y.H.
Ahmadzadehtalatapeh, M.
author_sort Yau, Y.H.
title Performance analysis of a heat pipe heat exchanger under different fluid charges
title_short Performance analysis of a heat pipe heat exchanger under different fluid charges
title_full Performance analysis of a heat pipe heat exchanger under different fluid charges
title_fullStr Performance analysis of a heat pipe heat exchanger under different fluid charges
title_full_unstemmed Performance analysis of a heat pipe heat exchanger under different fluid charges
title_sort performance analysis of a heat pipe heat exchanger under different fluid charges
publisher Taylor & Francis
publishDate 2014
url http://eprints.um.edu.my/11647/
_version_ 1643689107276169216
score 13.214268