A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation

Background In emergency settings, verification of endotracheal tube (ETT) location is important for critically ill patients. Ignorance of oesophageal intubation can be disastrous. Many methods are used for verification of the endotracheal tube location; none are ideal. Quantitative waveform capnogra...

Full description

Saved in:
Bibliographic Details
Main Authors: Adi, O., Chuan, T.W., Manikam, R.
Format: Article
Language:English
Published: 2013
Subjects:
Online Access:http://eprints.um.edu.my/10630/1/Adi-2013-A_feasibility_study.pdf
http://eprints.um.edu.my/10630/
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background In emergency settings, verification of endotracheal tube (ETT) location is important for critically ill patients. Ignorance of oesophageal intubation can be disastrous. Many methods are used for verification of the endotracheal tube location; none are ideal. Quantitative waveform capnography is considered the standard of care for this purpose but is not always available and is expensive. Therefore, this feasibility study is conducted to compare a cheaper alternative, bedside upper airway ultrasonography to waveform capnography, for verification of endotracheal tube location after intubation. Methods This was a prospective, single-centre, observational study, conducted at the HRPB, Ipoh. It included patients who were intubated in the emergency department from 28 March 2012 to 17 August 2012. A waiver of consent had been obtained from the Medical Research Ethics Committee. Bedside upper airway ultrasonography was performed after intubation and compared to waveform capnography. Specificity, sensitivity, positive and negative predictive value and likelihood ratio are calculated. Results A sample of 107 patients were analysed, and 6 (5.6) had oesophageal intubations. The overall accuracy of bedside upper airway ultrasonography was 98.1 (95 confidence interval (CI) 93.0 to 100.0). The kappa value (�) was 0.85, indicating a very good agreement between the bedside upper airway ultrasonography and waveform capnography. Thus, bedside upper airway ultrasonography is in concordance with waveform capnography. The sensitivity, specificity, positive predictive value and negative predictive value of bedside upper airway ultrasonography were 98.0 (95 CI 93.0 to 99.8), 100 (95 CI 54.1 to 100.0), 100 (95 CI 96.3 to 100.0) and 75.0 (95 CI 34.9 to 96.8). The likelihood ratio of a positive test is infinite and the likelihood ratio of a negative test is 0.0198 (95 CI 0.005 to 0.0781). The mean confirmation time by ultrasound is 16.4 s. No adverse effects were recorded. Conclusions Our study shows that ultrasonography can replace waveform capnography in confirming ETT placement in centres without capnography. This can reduce incidence of unrecognised oesophageal intubation and prevent morbidity and mortality.