The development of automatic smoke and LPG removal with fire alarm monitoring system / Muhammad Isqandar Putra Muhammad Zulqarnain

The number of people lose their live residentials in residential fire tend to rise every year. In a fire, deadly gases tend to spread father and faster than heat. That is one reason why most of the fire victims die from, which is from the inhalation of smoke and toxic gases, not from burns. Most fat...

Full description

Saved in:
Bibliographic Details
Main Author: Muhammad Zulqarnain, Muhammad Isqandar Putra
Format: Student Project
Language:English
Published: 2024
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/99858/1/99858.pdf
https://ir.uitm.edu.my/id/eprint/99858/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.99858
record_format eprints
spelling my.uitm.ir.998582025-02-06T09:38:19Z https://ir.uitm.edu.my/id/eprint/99858/ The development of automatic smoke and LPG removal with fire alarm monitoring system / Muhammad Isqandar Putra Muhammad Zulqarnain Muhammad Zulqarnain, Muhammad Isqandar Putra Indexes (General) The number of people lose their live residentials in residential fire tend to rise every year. In a fire, deadly gases tend to spread father and faster than heat. That is one reason why most of the fire victims die from, which is from the inhalation of smoke and toxic gases, not from burns. Most fatal fires happen when families are asleep because the occupant are not aware of the fire until they are trapped and there is no adequate time to escape. Furthermore, LPG is one of the reasons causes buildings to set on fire. LPG is classified as flammable substances and is colourless, odourless and heavier than air. The present of LPG could flash and explode if it encounters ignition source. To overcome this problem, the Development of Automatic Smoke and Gas Removal with Fire Alarm Monitoring system is proposed. Gas Sensor MQ-6, Smoke Sensor MQ-2, Fire detection sensor IR Flame Detection Sensor and DHT 22 Temperature sensor and push button has been used as input while piezo buzzer, L298N as motor driver, DC fan, LCD and Wi-Fi module (ESP8266) has been used as output and are connected to Arduino Gega 2560 as the main microcontroller. The Automatic Smoke and LPG Removal with Fire Alarm Monitoring System will be equipped with safety alarm Monitoring alarm to alert people inside the room that has been install the device that detected any dangerous gasses more specifically smoke and LPG gas and the buzzer, and DC- fan will turn ON to alert people and filter out the dangerous gas outside the room by using DC-fan. Moreover, this device could be developed to prevent any upcoming incident inside a room or building that are causes by fire and inhalations of toxic gases that are deadly. 2024 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/99858/1/99858.pdf The development of automatic smoke and LPG removal with fire alarm monitoring system / Muhammad Isqandar Putra Muhammad Zulqarnain. (2024) [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Indexes (General)
spellingShingle Indexes (General)
Muhammad Zulqarnain, Muhammad Isqandar Putra
The development of automatic smoke and LPG removal with fire alarm monitoring system / Muhammad Isqandar Putra Muhammad Zulqarnain
description The number of people lose their live residentials in residential fire tend to rise every year. In a fire, deadly gases tend to spread father and faster than heat. That is one reason why most of the fire victims die from, which is from the inhalation of smoke and toxic gases, not from burns. Most fatal fires happen when families are asleep because the occupant are not aware of the fire until they are trapped and there is no adequate time to escape. Furthermore, LPG is one of the reasons causes buildings to set on fire. LPG is classified as flammable substances and is colourless, odourless and heavier than air. The present of LPG could flash and explode if it encounters ignition source. To overcome this problem, the Development of Automatic Smoke and Gas Removal with Fire Alarm Monitoring system is proposed. Gas Sensor MQ-6, Smoke Sensor MQ-2, Fire detection sensor IR Flame Detection Sensor and DHT 22 Temperature sensor and push button has been used as input while piezo buzzer, L298N as motor driver, DC fan, LCD and Wi-Fi module (ESP8266) has been used as output and are connected to Arduino Gega 2560 as the main microcontroller. The Automatic Smoke and LPG Removal with Fire Alarm Monitoring System will be equipped with safety alarm Monitoring alarm to alert people inside the room that has been install the device that detected any dangerous gasses more specifically smoke and LPG gas and the buzzer, and DC- fan will turn ON to alert people and filter out the dangerous gas outside the room by using DC-fan. Moreover, this device could be developed to prevent any upcoming incident inside a room or building that are causes by fire and inhalations of toxic gases that are deadly.
format Student Project
author Muhammad Zulqarnain, Muhammad Isqandar Putra
author_facet Muhammad Zulqarnain, Muhammad Isqandar Putra
author_sort Muhammad Zulqarnain, Muhammad Isqandar Putra
title The development of automatic smoke and LPG removal with fire alarm monitoring system / Muhammad Isqandar Putra Muhammad Zulqarnain
title_short The development of automatic smoke and LPG removal with fire alarm monitoring system / Muhammad Isqandar Putra Muhammad Zulqarnain
title_full The development of automatic smoke and LPG removal with fire alarm monitoring system / Muhammad Isqandar Putra Muhammad Zulqarnain
title_fullStr The development of automatic smoke and LPG removal with fire alarm monitoring system / Muhammad Isqandar Putra Muhammad Zulqarnain
title_full_unstemmed The development of automatic smoke and LPG removal with fire alarm monitoring system / Muhammad Isqandar Putra Muhammad Zulqarnain
title_sort development of automatic smoke and lpg removal with fire alarm monitoring system / muhammad isqandar putra muhammad zulqarnain
publishDate 2024
url https://ir.uitm.edu.my/id/eprint/99858/1/99858.pdf
https://ir.uitm.edu.my/id/eprint/99858/
_version_ 1823540785817059328