Lightning risk assessment for structure at remote location: article / Mohammad Rafeuddien Arifin

This paper presents the method of lightning risk assessment for the structure by using the Malaysian Standard. The aim of this study is to determine the risk for the structure located at remote area from lightning activity and to provide the suitable lightning protection measures in order to reduce...

Full description

Saved in:
Bibliographic Details
Main Author: Arifin, Mohammad Rafeuddien
Format: Article
Language:English
Published: Universiti Teknologi MARA (UiTM) 2011
Online Access:https://ir.uitm.edu.my/id/eprint/86914/1/86914.PDF
https://ir.uitm.edu.my/id/eprint/86914/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.86914
record_format eprints
spelling my.uitm.ir.869142024-06-21T07:05:14Z https://ir.uitm.edu.my/id/eprint/86914/ Lightning risk assessment for structure at remote location: article / Mohammad Rafeuddien Arifin Arifin, Mohammad Rafeuddien This paper presents the method of lightning risk assessment for the structure by using the Malaysian Standard. The aim of this study is to determine the risk for the structure located at remote area from lightning activity and to provide the suitable lightning protection measures in order to reduce the risk for the structure lower than tolerable risk. To achieve this aim, the following objectives have been identified: to evaluate the risk analysis for the structure using Malaysian Standard and to determine the suitable protection for the structure. In order to evaluate whether or not lightning protection of an object is needed, risk assessment in accordance with the procedures contained in IEC MS 62305. This method will allow more precise selection of lightning protection devices. Based on the assessment, the risk, R! shall be determined and compared with the tolerable value RT= 10"3. The protection is required if the risk Ri is higher than tolerable risk, RT. Based on the calculation, the value of Ri = 1.7972x10"3 is higher than the tolerable value, RT = 10"3, the lightning protection is required for the structure. To reduce the risk Ri, the best solutions is to install coordinated SPD at the service entrance to protect both power and telecom lines. Universiti Teknologi MARA (UiTM) 2011 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/86914/1/86914.PDF Lightning risk assessment for structure at remote location: article / Mohammad Rafeuddien Arifin. (2011) pp. 1-6.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
description This paper presents the method of lightning risk assessment for the structure by using the Malaysian Standard. The aim of this study is to determine the risk for the structure located at remote area from lightning activity and to provide the suitable lightning protection measures in order to reduce the risk for the structure lower than tolerable risk. To achieve this aim, the following objectives have been identified: to evaluate the risk analysis for the structure using Malaysian Standard and to determine the suitable protection for the structure. In order to evaluate whether or not lightning protection of an object is needed, risk assessment in accordance with the procedures contained in IEC MS 62305. This method will allow more precise selection of lightning protection devices. Based on the assessment, the risk, R! shall be determined and compared with the tolerable value RT= 10"3. The protection is required if the risk Ri is higher than tolerable risk, RT. Based on the calculation, the value of Ri = 1.7972x10"3 is higher than the tolerable value, RT = 10"3, the lightning protection is required for the structure. To reduce the risk Ri, the best solutions is to install coordinated SPD at the service entrance to protect both power and telecom lines.
format Article
author Arifin, Mohammad Rafeuddien
spellingShingle Arifin, Mohammad Rafeuddien
Lightning risk assessment for structure at remote location: article / Mohammad Rafeuddien Arifin
author_facet Arifin, Mohammad Rafeuddien
author_sort Arifin, Mohammad Rafeuddien
title Lightning risk assessment for structure at remote location: article / Mohammad Rafeuddien Arifin
title_short Lightning risk assessment for structure at remote location: article / Mohammad Rafeuddien Arifin
title_full Lightning risk assessment for structure at remote location: article / Mohammad Rafeuddien Arifin
title_fullStr Lightning risk assessment for structure at remote location: article / Mohammad Rafeuddien Arifin
title_full_unstemmed Lightning risk assessment for structure at remote location: article / Mohammad Rafeuddien Arifin
title_sort lightning risk assessment for structure at remote location: article / mohammad rafeuddien arifin
publisher Universiti Teknologi MARA (UiTM)
publishDate 2011
url https://ir.uitm.edu.my/id/eprint/86914/1/86914.PDF
https://ir.uitm.edu.my/id/eprint/86914/
_version_ 1802981080852070400
score 13.214267