Identification of fault and load increase to prevent distance relay mal-operation / Faten Hamima Ismail

Zone 3 distance relay mal-operation due to overloading has been identified as one of the factors of blackouts in the world. One of the causes that lead to this problem is it cannot differentiate between fault occurrence and load increase in transmission lines. Therefore, it is important for us to di...

Full description

Saved in:
Bibliographic Details
Main Author: Ismail, Faten Hamima
Format: Thesis
Language:English
Published: 2012
Online Access:https://ir.uitm.edu.my/id/eprint/84868/1/84868.pdf
https://ir.uitm.edu.my/id/eprint/84868/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.84868
record_format eprints
spelling my.uitm.ir.848682024-03-20T16:24:11Z https://ir.uitm.edu.my/id/eprint/84868/ Identification of fault and load increase to prevent distance relay mal-operation / Faten Hamima Ismail Ismail, Faten Hamima Zone 3 distance relay mal-operation due to overloading has been identified as one of the factors of blackouts in the world. One of the causes that lead to this problem is it cannot differentiate between fault occurrence and load increase in transmission lines. Therefore, it is important for us to distinguish between two of the disturbances in order to improve the reliability of distance relay performance. The main objective of this project is to find an indicator that can differentiate between fault occurrence and load increase. This paper presents a proposed method to identify fault occurrence and load increase in transmission line by analyzing instantaneous voltage and root mean square (RMS) voltage signal waveform measured at the remote buses. The proposed technique is designed and validated through simulations of IEEE 9-bus test system in PSCAD. The waveforms of instantaneous voltage as well as RMS voltage measured have been plotted using Microsoft Excel. Analyses of the waveforms have been carried out in order to differentiate the characteristics between two of the disturbances. The results show that there are different characteristic of voltage waveform that can clearly indicates fault occurrence and load increase. The difference between two of them can be identified as fast as in time of one cycle after the occurrence. Therefore, it is suitable to be implemented on Zone 3 distance relay operation because the operation of the zone has time delay in the order of 90 cycles. 2012 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/84868/1/84868.pdf Identification of fault and load increase to prevent distance relay mal-operation / Faten Hamima Ismail. (2012) Degree thesis, thesis, Universiti Teknologi MARA (UiTM).
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
description Zone 3 distance relay mal-operation due to overloading has been identified as one of the factors of blackouts in the world. One of the causes that lead to this problem is it cannot differentiate between fault occurrence and load increase in transmission lines. Therefore, it is important for us to distinguish between two of the disturbances in order to improve the reliability of distance relay performance. The main objective of this project is to find an indicator that can differentiate between fault occurrence and load increase. This paper presents a proposed method to identify fault occurrence and load increase in transmission line by analyzing instantaneous voltage and root mean square (RMS) voltage signal waveform measured at the remote buses. The proposed technique is designed and validated through simulations of IEEE 9-bus test system in PSCAD. The waveforms of instantaneous voltage as well as RMS voltage measured have been plotted using Microsoft Excel. Analyses of the waveforms have been carried out in order to differentiate the characteristics between two of the disturbances. The results show that there are different characteristic of voltage waveform that can clearly indicates fault occurrence and load increase. The difference between two of them can be identified as fast as in time of one cycle after the occurrence. Therefore, it is suitable to be implemented on Zone 3 distance relay operation because the operation of the zone has time delay in the order of 90 cycles.
format Thesis
author Ismail, Faten Hamima
spellingShingle Ismail, Faten Hamima
Identification of fault and load increase to prevent distance relay mal-operation / Faten Hamima Ismail
author_facet Ismail, Faten Hamima
author_sort Ismail, Faten Hamima
title Identification of fault and load increase to prevent distance relay mal-operation / Faten Hamima Ismail
title_short Identification of fault and load increase to prevent distance relay mal-operation / Faten Hamima Ismail
title_full Identification of fault and load increase to prevent distance relay mal-operation / Faten Hamima Ismail
title_fullStr Identification of fault and load increase to prevent distance relay mal-operation / Faten Hamima Ismail
title_full_unstemmed Identification of fault and load increase to prevent distance relay mal-operation / Faten Hamima Ismail
title_sort identification of fault and load increase to prevent distance relay mal-operation / faten hamima ismail
publishDate 2012
url https://ir.uitm.edu.my/id/eprint/84868/1/84868.pdf
https://ir.uitm.edu.my/id/eprint/84868/
_version_ 1794641202083004416
score 13.160551