Service restoration with the presence of distributed generation in a distribution system / Masruddin Samsuddin

This project studies the influence of distributed generation during service restoration and to identify the optimal network reconfiguration at the power distribution systems for loss reduction and voltage profile improvement under fault condition with the installation of distributed generation. It i...

Full description

Saved in:
Bibliographic Details
Main Author: Samsuddin, Masruddin
Format: Thesis
Language:English
Published: 2009
Online Access:https://ir.uitm.edu.my/id/eprint/84860/1/84860.pdf
https://ir.uitm.edu.my/id/eprint/84860/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.84860
record_format eprints
spelling my.uitm.ir.848602024-01-15T09:00:18Z https://ir.uitm.edu.my/id/eprint/84860/ Service restoration with the presence of distributed generation in a distribution system / Masruddin Samsuddin Samsuddin, Masruddin This project studies the influence of distributed generation during service restoration and to identify the optimal network reconfiguration at the power distribution systems for loss reduction and voltage profile improvement under fault condition with the installation of distributed generation. It is assumed that after the occurrence of fault at particular section of a distribution network, the loads get disconnected and are left unsupplied. Service should be restored to the affected loads through a network reconfiguration procedure. The simulation was conducted by applying three phase fault at an identified location. In this study, network reconfiguration was implemented using the TOPO application in the power system simulation programmed for planning, design and analysis of distribution system (PSS/Adept). This application determines the optimal sectionalizing-tie switch pairs based on minimum losses configuration and at the same time, all nodes are assured for the supply. The location of the distributed generation was identified by finding the minimum bus voltage. The results show that installing distributed generation at the suitable location with appropriate sizing has able to provide lower loss level and higher voltage profile in fault condition as compared to that obtained before installed distributed generation and network reconfiguration. The proposed study was conducted on the IEEE 69 bus distribution system. 2009 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/84860/1/84860.pdf Service restoration with the presence of distributed generation in a distribution system / Masruddin Samsuddin. (2009) Degree thesis, thesis, Universiti Teknologi MARA (UiTM).
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
description This project studies the influence of distributed generation during service restoration and to identify the optimal network reconfiguration at the power distribution systems for loss reduction and voltage profile improvement under fault condition with the installation of distributed generation. It is assumed that after the occurrence of fault at particular section of a distribution network, the loads get disconnected and are left unsupplied. Service should be restored to the affected loads through a network reconfiguration procedure. The simulation was conducted by applying three phase fault at an identified location. In this study, network reconfiguration was implemented using the TOPO application in the power system simulation programmed for planning, design and analysis of distribution system (PSS/Adept). This application determines the optimal sectionalizing-tie switch pairs based on minimum losses configuration and at the same time, all nodes are assured for the supply. The location of the distributed generation was identified by finding the minimum bus voltage. The results show that installing distributed generation at the suitable location with appropriate sizing has able to provide lower loss level and higher voltage profile in fault condition as compared to that obtained before installed distributed generation and network reconfiguration. The proposed study was conducted on the IEEE 69 bus distribution system.
format Thesis
author Samsuddin, Masruddin
spellingShingle Samsuddin, Masruddin
Service restoration with the presence of distributed generation in a distribution system / Masruddin Samsuddin
author_facet Samsuddin, Masruddin
author_sort Samsuddin, Masruddin
title Service restoration with the presence of distributed generation in a distribution system / Masruddin Samsuddin
title_short Service restoration with the presence of distributed generation in a distribution system / Masruddin Samsuddin
title_full Service restoration with the presence of distributed generation in a distribution system / Masruddin Samsuddin
title_fullStr Service restoration with the presence of distributed generation in a distribution system / Masruddin Samsuddin
title_full_unstemmed Service restoration with the presence of distributed generation in a distribution system / Masruddin Samsuddin
title_sort service restoration with the presence of distributed generation in a distribution system / masruddin samsuddin
publishDate 2009
url https://ir.uitm.edu.my/id/eprint/84860/1/84860.pdf
https://ir.uitm.edu.my/id/eprint/84860/
_version_ 1789429220482482176
score 13.18916