Classification of partial discharge using combination of acoustic emission detection and S-transform analysis / Mohd Hakim Shahbudin

Partial Discharge (PD) is an electrical phenomenon which causes insulation to deteriorate and frequently is the reason for breakdown of an insulation system resulting in failure of the equipment. This project is conducted in order to identify a detected partial discharged using non-contact type of a...

詳細記述

保存先:
書誌詳細
第一著者: Shahbudin, Mohd Hakim
フォーマット: 学位論文
言語:English
出版事項: 2013
オンライン・アクセス:https://ir.uitm.edu.my/id/eprint/84509/1/84509.pdf
https://ir.uitm.edu.my/id/eprint/84509/
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
その他の書誌記述
要約:Partial Discharge (PD) is an electrical phenomenon which causes insulation to deteriorate and frequently is the reason for breakdown of an insulation system resulting in failure of the equipment. This project is conducted in order to identify a detected partial discharged using non-contact type of acoustic measurement. This study will be performed with laboratory experimental work in order to validate the experimental data. With the aid of an ultrasonic probe as detecting device, the ultrasonic signal is recorded and the data will be analysed in personal computer (PC) with the aid of MATLAB software. The recorded time-domain signal is then transformed into frequency-domain by using the S-Transform (ST) analysis. This study is to detect the acoustic PD and classify the pattern of ultrasonic sound emitted.