Knee dynamic analysis based on 2D-to-3D registration of fluoroscopic and angiographic images / Amir Hossein Saveh ... [et al.]

This paper introduces a method to measure the kinematics of the knee using fluoroscopic imaging. The method involves two stages. In the first, the knee joint is recorded during normal gait by fluoroscopy using a mobile C-arm and an angiographic imaging system. The images then were processed to ca...

Full description

Saved in:
Bibliographic Details
Main Authors: Saveh, Amir Hossein, Kazemi, Seyyed Morteza, Yussof, Hanafiah, Katouzian, Hamid Reza, Vanat, Qureish, Chizari, Mahmoud
Format: Article
Language:English
Published: Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM) 2012
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/8399/1/AJ_AMIR%20HOSSEIN%20SAVEH%20JME%2012.pdf
http://ir.uitm.edu.my/id/eprint/8399/
https://jmeche.uitm.edu.my/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.8399
record_format eprints
spelling my.uitm.ir.83992016-08-05T08:03:28Z http://ir.uitm.edu.my/id/eprint/8399/ Knee dynamic analysis based on 2D-to-3D registration of fluoroscopic and angiographic images / Amir Hossein Saveh ... [et al.] Saveh, Amir Hossein Kazemi, Seyyed Morteza Yussof, Hanafiah Katouzian, Hamid Reza Vanat, Qureish Chizari, Mahmoud Diseases of the circulatory (Cardiovascular) system Surgery by region, system, or organ This paper introduces a method to measure the kinematics of the knee using fluoroscopic imaging. The method involves two stages. In the first, the knee joint is recorded during normal gait by fluoroscopy using a mobile C-arm and an angiographic imaging system. The images then were processed to calculate the two-dimensional (2D) kinematics of the joint during the different phases of the gait cycle. This was then used to calculate three-dimensional (3D) kinematics of the joint. In parallel the reaction force on the knee joint was calculated using gait lab analysis. In the second stage, the 3D finite element model of the knee was created using computerised tomography (CT) and magnetic resonance imaging (MRI) data. The model was then used to analyse the joint contact loads during the gait cycle based on the input data obtained from the kinematic and reaction force data from stage one. This allowed the analysis of the mechanical behaviour of the knee and thus the stress distribution on the medial and lateral compartments of the knee. Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM) 2012 Article PeerReviewed text en http://ir.uitm.edu.my/id/eprint/8399/1/AJ_AMIR%20HOSSEIN%20SAVEH%20JME%2012.pdf Saveh, Amir Hossein and Kazemi, Seyyed Morteza and Yussof, Hanafiah and Katouzian, Hamid Reza and Vanat, Qureish and Chizari, Mahmoud (2012) Knee dynamic analysis based on 2D-to-3D registration of fluoroscopic and angiographic images / Amir Hossein Saveh ... [et al.]. Journal of Mechanical Engineering (JMechE), 9 (1). pp. 79-97. ISSN 1823-5514 ; 2550-164X https://jmeche.uitm.edu.my/
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Diseases of the circulatory (Cardiovascular) system
Surgery by region, system, or organ
spellingShingle Diseases of the circulatory (Cardiovascular) system
Surgery by region, system, or organ
Saveh, Amir Hossein
Kazemi, Seyyed Morteza
Yussof, Hanafiah
Katouzian, Hamid Reza
Vanat, Qureish
Chizari, Mahmoud
Knee dynamic analysis based on 2D-to-3D registration of fluoroscopic and angiographic images / Amir Hossein Saveh ... [et al.]
description This paper introduces a method to measure the kinematics of the knee using fluoroscopic imaging. The method involves two stages. In the first, the knee joint is recorded during normal gait by fluoroscopy using a mobile C-arm and an angiographic imaging system. The images then were processed to calculate the two-dimensional (2D) kinematics of the joint during the different phases of the gait cycle. This was then used to calculate three-dimensional (3D) kinematics of the joint. In parallel the reaction force on the knee joint was calculated using gait lab analysis. In the second stage, the 3D finite element model of the knee was created using computerised tomography (CT) and magnetic resonance imaging (MRI) data. The model was then used to analyse the joint contact loads during the gait cycle based on the input data obtained from the kinematic and reaction force data from stage one. This allowed the analysis of the mechanical behaviour of the knee and thus the stress distribution on the medial and lateral compartments of the knee.
format Article
author Saveh, Amir Hossein
Kazemi, Seyyed Morteza
Yussof, Hanafiah
Katouzian, Hamid Reza
Vanat, Qureish
Chizari, Mahmoud
author_facet Saveh, Amir Hossein
Kazemi, Seyyed Morteza
Yussof, Hanafiah
Katouzian, Hamid Reza
Vanat, Qureish
Chizari, Mahmoud
author_sort Saveh, Amir Hossein
title Knee dynamic analysis based on 2D-to-3D registration of fluoroscopic and angiographic images / Amir Hossein Saveh ... [et al.]
title_short Knee dynamic analysis based on 2D-to-3D registration of fluoroscopic and angiographic images / Amir Hossein Saveh ... [et al.]
title_full Knee dynamic analysis based on 2D-to-3D registration of fluoroscopic and angiographic images / Amir Hossein Saveh ... [et al.]
title_fullStr Knee dynamic analysis based on 2D-to-3D registration of fluoroscopic and angiographic images / Amir Hossein Saveh ... [et al.]
title_full_unstemmed Knee dynamic analysis based on 2D-to-3D registration of fluoroscopic and angiographic images / Amir Hossein Saveh ... [et al.]
title_sort knee dynamic analysis based on 2d-to-3d registration of fluoroscopic and angiographic images / amir hossein saveh ... [et al.]
publisher Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM)
publishDate 2012
url http://ir.uitm.edu.my/id/eprint/8399/1/AJ_AMIR%20HOSSEIN%20SAVEH%20JME%2012.pdf
http://ir.uitm.edu.my/id/eprint/8399/
https://jmeche.uitm.edu.my/
_version_ 1685648241998168064
score 13.211869