The influence of ceramic veneering technique and coping-veneer ratio on fracture toughness of implant retained zirconia and metal-ceramic crowns / Fahim Ahmed Vohra

Zirconia (Zr) restorations are one of the exceptional innovations in modern dentistry. Although Zr demonstrates good stability as a framework material, veneer fracture and chipping has emerged as a common limitation for Zr ceramic crowns (ZCC) in function. The purpose of this study is to investigate...

Full description

Saved in:
Bibliographic Details
Main Author: Ahmed Vohra, Fahim
Format: Thesis
Language:English
Published: 2019
Online Access:https://ir.uitm.edu.my/id/eprint/83967/1/83967.pdf
https://ir.uitm.edu.my/id/eprint/83967/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.83967
record_format eprints
spelling my.uitm.ir.839672023-11-22T03:17:10Z https://ir.uitm.edu.my/id/eprint/83967/ The influence of ceramic veneering technique and coping-veneer ratio on fracture toughness of implant retained zirconia and metal-ceramic crowns / Fahim Ahmed Vohra Ahmed Vohra, Fahim Zirconia (Zr) restorations are one of the exceptional innovations in modern dentistry. Although Zr demonstrates good stability as a framework material, veneer fracture and chipping has emerged as a common limitation for Zr ceramic crowns (ZCC) in function. The purpose of this study is to investigate the influence of veneering technique and veneer-coping (V/C) thickness and ratio on the fracture toughness of implant retained zirconia ceramic crowns (ZCC) and metal ceramic crowns (MCC). In study A, 40 zirconia and metal copings were divided into 2 groups of 0.5mm and 1mm coping thickness (n=20). Half of the 0.5mm and 1mm copings (ZCC & MCC) were veneered with an overall thickness of 3mm and 4mm respectively. Half of all copings (ZCC & MCC) were veneered using layering (LR) and the remaining half using hot press (HR) method (n=10). In study B, seventy copings each of metal and zirconia were fabricated using the CAD-CAM technique. Veneering ceramic was applied using hot-pressing technique for both MCC and ZCC specimens. The groups within each material (ZCC & MCC) were based on different coping thickness (0.5,0.7 & 1.0mm) and overall sample (2.0, 2.3 & 2.5mm) thickness. Specimens in each group were assessed for fracture toughness using micro-indenter. Crack lengths for specimens were evaluated to calculate KIC (fracture toughness). All specimens were cemented to titanium implant abutments and tested using micro indenter. Crack lengths for all specimens was measured which was then utilized to calculate fracture toughness. ANOVA was utilized to analyze the results. In study A, V/C thickness of 2.5/0.5 and 3.5/0.5 showed significantly better (p=0.001) fracture toughness as compared to V/C thickness of 2/1 and 3/1 for implant retained ZCC. MCC (V/C 2.5/0.5) showed significantly higher fracture toughness (3.18 ± 0.74 MPa, p= 0.01) as compared to ZCC of similar V/C thickness (2.77 ± 0.29 MPa). Fracture toughness (KIC) values for LR and HR veneered zirconia copings of similar V/C thickness were comparable (p=0.409). For study B, among MCC specimens, increasing V/C ratio showed higher KIC (p=0.019). Increasing veneer thickness from 1.3mm (2.71 ± 0.32 MPa) to 1.8mm (3.36± 0.58 MPa) improved (p=0.006) KIC, however KIC values were comparable (p=0.086) with different coping thickness for MCC specimens. For ZCC specimens, V/C ratio (p=0.0444), veneer thickness (p=0.035) and coping thickness (p=0.032), all showed significant influence on KIC. Veneer-coping ratio significantly influenced fracture toughness of veneered implant retained ZCC (p<0.05) and maximum KIC among ZCC was achieved for 3mm specimens with a V/C thickness of 2.5/0.5mm (2.91± 0.43) . Ceramic veneering technique did not influence fracture toughness of bilayered ZCC. Overall MCC showed higher KIC compared to ZCC specimens. Coping thickness, veneer thickness and V/C ratio showed significant influence on fracture toughness of bilayered ZCC specimens. Veneer thickness and V/C ratio showed significant influence on fracture toughness of bilayered MCC specimens.. 2019 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/83967/1/83967.pdf The influence of ceramic veneering technique and coping-veneer ratio on fracture toughness of implant retained zirconia and metal-ceramic crowns / Fahim Ahmed Vohra. (2019) PhD thesis, thesis, Universiti Teknologi MARA (UiTM).
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
description Zirconia (Zr) restorations are one of the exceptional innovations in modern dentistry. Although Zr demonstrates good stability as a framework material, veneer fracture and chipping has emerged as a common limitation for Zr ceramic crowns (ZCC) in function. The purpose of this study is to investigate the influence of veneering technique and veneer-coping (V/C) thickness and ratio on the fracture toughness of implant retained zirconia ceramic crowns (ZCC) and metal ceramic crowns (MCC). In study A, 40 zirconia and metal copings were divided into 2 groups of 0.5mm and 1mm coping thickness (n=20). Half of the 0.5mm and 1mm copings (ZCC & MCC) were veneered with an overall thickness of 3mm and 4mm respectively. Half of all copings (ZCC & MCC) were veneered using layering (LR) and the remaining half using hot press (HR) method (n=10). In study B, seventy copings each of metal and zirconia were fabricated using the CAD-CAM technique. Veneering ceramic was applied using hot-pressing technique for both MCC and ZCC specimens. The groups within each material (ZCC & MCC) were based on different coping thickness (0.5,0.7 & 1.0mm) and overall sample (2.0, 2.3 & 2.5mm) thickness. Specimens in each group were assessed for fracture toughness using micro-indenter. Crack lengths for specimens were evaluated to calculate KIC (fracture toughness). All specimens were cemented to titanium implant abutments and tested using micro indenter. Crack lengths for all specimens was measured which was then utilized to calculate fracture toughness. ANOVA was utilized to analyze the results. In study A, V/C thickness of 2.5/0.5 and 3.5/0.5 showed significantly better (p=0.001) fracture toughness as compared to V/C thickness of 2/1 and 3/1 for implant retained ZCC. MCC (V/C 2.5/0.5) showed significantly higher fracture toughness (3.18 ± 0.74 MPa, p= 0.01) as compared to ZCC of similar V/C thickness (2.77 ± 0.29 MPa). Fracture toughness (KIC) values for LR and HR veneered zirconia copings of similar V/C thickness were comparable (p=0.409). For study B, among MCC specimens, increasing V/C ratio showed higher KIC (p=0.019). Increasing veneer thickness from 1.3mm (2.71 ± 0.32 MPa) to 1.8mm (3.36± 0.58 MPa) improved (p=0.006) KIC, however KIC values were comparable (p=0.086) with different coping thickness for MCC specimens. For ZCC specimens, V/C ratio (p=0.0444), veneer thickness (p=0.035) and coping thickness (p=0.032), all showed significant influence on KIC. Veneer-coping ratio significantly influenced fracture toughness of veneered implant retained ZCC (p<0.05) and maximum KIC among ZCC was achieved for 3mm specimens with a V/C thickness of 2.5/0.5mm (2.91± 0.43) . Ceramic veneering technique did not influence fracture toughness of bilayered ZCC. Overall MCC showed higher KIC compared to ZCC specimens. Coping thickness, veneer thickness and V/C ratio showed significant influence on fracture toughness of bilayered ZCC specimens. Veneer thickness and V/C ratio showed significant influence on fracture toughness of bilayered MCC specimens..
format Thesis
author Ahmed Vohra, Fahim
spellingShingle Ahmed Vohra, Fahim
The influence of ceramic veneering technique and coping-veneer ratio on fracture toughness of implant retained zirconia and metal-ceramic crowns / Fahim Ahmed Vohra
author_facet Ahmed Vohra, Fahim
author_sort Ahmed Vohra, Fahim
title The influence of ceramic veneering technique and coping-veneer ratio on fracture toughness of implant retained zirconia and metal-ceramic crowns / Fahim Ahmed Vohra
title_short The influence of ceramic veneering technique and coping-veneer ratio on fracture toughness of implant retained zirconia and metal-ceramic crowns / Fahim Ahmed Vohra
title_full The influence of ceramic veneering technique and coping-veneer ratio on fracture toughness of implant retained zirconia and metal-ceramic crowns / Fahim Ahmed Vohra
title_fullStr The influence of ceramic veneering technique and coping-veneer ratio on fracture toughness of implant retained zirconia and metal-ceramic crowns / Fahim Ahmed Vohra
title_full_unstemmed The influence of ceramic veneering technique and coping-veneer ratio on fracture toughness of implant retained zirconia and metal-ceramic crowns / Fahim Ahmed Vohra
title_sort influence of ceramic veneering technique and coping-veneer ratio on fracture toughness of implant retained zirconia and metal-ceramic crowns / fahim ahmed vohra
publishDate 2019
url https://ir.uitm.edu.my/id/eprint/83967/1/83967.pdf
https://ir.uitm.edu.my/id/eprint/83967/
_version_ 1783882231293411328
score 13.159267