Effect of circuit breaker reclosure time on the performance of a power system: article / Tuan Affindi Tuan Abdullah

The magnitude and duration ofrestrikes upon the reclosure of the terminals of a circuit-breaker is important as failure to close at the right time may lead to detrimental effect to the power system in which the circuit breaker reside. For the purpose of demonstrating the operation of the circuit bre...

Full description

Saved in:
Bibliographic Details
Main Author: Tuan Abdullah, Tuan Affindi
Format: Article
Language:English
Published: Universiti Teknologi MARA (UiTM) 2008
Online Access:https://ir.uitm.edu.my/id/eprint/72610/1/72610.PDF
https://ir.uitm.edu.my/id/eprint/72610/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.72610
record_format eprints
spelling my.uitm.ir.726102024-06-21T07:13:44Z https://ir.uitm.edu.my/id/eprint/72610/ Effect of circuit breaker reclosure time on the performance of a power system: article / Tuan Affindi Tuan Abdullah Tuan Abdullah, Tuan Affindi The magnitude and duration ofrestrikes upon the reclosure of the terminals of a circuit-breaker is important as failure to close at the right time may lead to detrimental effect to the power system in which the circuit breaker reside. For the purpose of demonstrating the operation of the circuit breaker to high voltage engineering students, this project is undertaken. A model of the power system in which the circuit breaker resides is designed based on the IEC standard. At the source side of the circuit breaker a circuit is present for reproducing a (2-parameter IEC) transient recovery voltage, while the RLC circuit at the line side represents a short transmission line that is short circuited. An single-shot pulse generator represents the source of surge. The simulation was conducted using MATLAB' Simulink (MLS). The performance of the power system is analysed in terms of the magnitude and duration of the restr iking voltages. By comparing the switching time made at various points on the sinusoidal power source, the importance of correct switching time can be appreciated Universiti Teknologi MARA (UiTM) 2008 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/72610/1/72610.PDF Effect of circuit breaker reclosure time on the performance of a power system: article / Tuan Affindi Tuan Abdullah. (2008) pp. 1-5.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
description The magnitude and duration ofrestrikes upon the reclosure of the terminals of a circuit-breaker is important as failure to close at the right time may lead to detrimental effect to the power system in which the circuit breaker reside. For the purpose of demonstrating the operation of the circuit breaker to high voltage engineering students, this project is undertaken. A model of the power system in which the circuit breaker resides is designed based on the IEC standard. At the source side of the circuit breaker a circuit is present for reproducing a (2-parameter IEC) transient recovery voltage, while the RLC circuit at the line side represents a short transmission line that is short circuited. An single-shot pulse generator represents the source of surge. The simulation was conducted using MATLAB' Simulink (MLS). The performance of the power system is analysed in terms of the magnitude and duration of the restr iking voltages. By comparing the switching time made at various points on the sinusoidal power source, the importance of correct switching time can be appreciated
format Article
author Tuan Abdullah, Tuan Affindi
spellingShingle Tuan Abdullah, Tuan Affindi
Effect of circuit breaker reclosure time on the performance of a power system: article / Tuan Affindi Tuan Abdullah
author_facet Tuan Abdullah, Tuan Affindi
author_sort Tuan Abdullah, Tuan Affindi
title Effect of circuit breaker reclosure time on the performance of a power system: article / Tuan Affindi Tuan Abdullah
title_short Effect of circuit breaker reclosure time on the performance of a power system: article / Tuan Affindi Tuan Abdullah
title_full Effect of circuit breaker reclosure time on the performance of a power system: article / Tuan Affindi Tuan Abdullah
title_fullStr Effect of circuit breaker reclosure time on the performance of a power system: article / Tuan Affindi Tuan Abdullah
title_full_unstemmed Effect of circuit breaker reclosure time on the performance of a power system: article / Tuan Affindi Tuan Abdullah
title_sort effect of circuit breaker reclosure time on the performance of a power system: article / tuan affindi tuan abdullah
publisher Universiti Teknologi MARA (UiTM)
publishDate 2008
url https://ir.uitm.edu.my/id/eprint/72610/1/72610.PDF
https://ir.uitm.edu.my/id/eprint/72610/
_version_ 1802981076811907072
score 13.160551