Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.]

Background: Electronic Apex Locators (EAL) has been increasingly used to facilitate working length determination in endodontics. This instrument is becoming more important to be used in addition to radiographs. A steep learning curve has existed between EAL use in the clinical, from the pre-clinical...

Full description

Saved in:
Bibliographic Details
Main Authors: Berhanuddin, Muhamad Asyraf, Mohamad, Nurul Fasiha, Ayoub, Afzan Adilah, Kamaruzaman, Marlena, Baharuddin, Izyan Hazwani, Ismail, Ikmal Hisham
Format: Article
Language:English
Published: Faculty of Dentistry, Universiti Teknologi MARA 2021
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/69429/1/69429.pdf
https://ir.uitm.edu.my/id/eprint/69429/
https://doi.org/10.24191/cos.v8i0.17483
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.69429
record_format eprints
spelling my.uitm.ir.694292022-10-31T06:40:19Z https://ir.uitm.edu.my/id/eprint/69429/ Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.] Berhanuddin, Muhamad Asyraf Mohamad, Nurul Fasiha Ayoub, Afzan Adilah Kamaruzaman, Marlena Baharuddin, Izyan Hazwani Ismail, Ikmal Hisham Dental health education Prosthetic dentistry. Prosthodontics Background: Electronic Apex Locators (EAL) has been increasingly used to facilitate working length determination in endodontics. This instrument is becoming more important to be used in addition to radiographs. A steep learning curve has existed between EAL use in the clinical, from the pre-clinical settings. Objectives: To fabricate a model that will facilitate dental students to use Electronic Apex Locator (EAL) in the dental simulation clinic and to conduct a questionnaire-based survey to investigate Electronic Apex Locator Model (EALM) effectiveness. Materials and Methods: Construction of model master jaw, EALM, using materials available in the prosthetic laboratory. The model can be mounted on the phantom head which when connected to an EAL will simulate its clinical use. A validated questionnaire was distributed to a group of n=10 pre-clinical students before and after demonstration conducted at the simulation clinic. Results: A prototype EALM was successfully fabricated at Universiti Teknologi MARA Dental Prosthetic Laboratory. with features incorporating conductive-media-chamber, with attached anatomically-correct fabricated model teeth. The teeth were constructed incorporating continuous access cavity, root canal, through to a patent apex. When attached to the jaw model, the electrical circuit was connected allowing EAL to function. Conclusion: EALM can be conveniently constructed at the Dental Prosthetic Laboratory by using materials readily available here. Furthermore, a steep learning curve exist between pre-clinical and clinical studies was bridged by the use this EALM and this allowed familiarity of clinical handling EAL. However, this study was limited by the small number of students exposed to this new method. Further prospective study is required by increasing the sample size to provide more significant results. Faculty of Dentistry, Universiti Teknologi MARA 2021 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/69429/1/69429.pdf Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.]. (2021) Compendium of Oral Science (CORALS), 8. pp. 55-68. ISSN 2489-1102; 2637-0611 https://doi.org/10.24191/cos.v8i0.17483
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Dental health education
Prosthetic dentistry. Prosthodontics
spellingShingle Dental health education
Prosthetic dentistry. Prosthodontics
Berhanuddin, Muhamad Asyraf
Mohamad, Nurul Fasiha
Ayoub, Afzan Adilah
Kamaruzaman, Marlena
Baharuddin, Izyan Hazwani
Ismail, Ikmal Hisham
Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.]
description Background: Electronic Apex Locators (EAL) has been increasingly used to facilitate working length determination in endodontics. This instrument is becoming more important to be used in addition to radiographs. A steep learning curve has existed between EAL use in the clinical, from the pre-clinical settings. Objectives: To fabricate a model that will facilitate dental students to use Electronic Apex Locator (EAL) in the dental simulation clinic and to conduct a questionnaire-based survey to investigate Electronic Apex Locator Model (EALM) effectiveness. Materials and Methods: Construction of model master jaw, EALM, using materials available in the prosthetic laboratory. The model can be mounted on the phantom head which when connected to an EAL will simulate its clinical use. A validated questionnaire was distributed to a group of n=10 pre-clinical students before and after demonstration conducted at the simulation clinic. Results: A prototype EALM was successfully fabricated at Universiti Teknologi MARA Dental Prosthetic Laboratory. with features incorporating conductive-media-chamber, with attached anatomically-correct fabricated model teeth. The teeth were constructed incorporating continuous access cavity, root canal, through to a patent apex. When attached to the jaw model, the electrical circuit was connected allowing EAL to function. Conclusion: EALM can be conveniently constructed at the Dental Prosthetic Laboratory by using materials readily available here. Furthermore, a steep learning curve exist between pre-clinical and clinical studies was bridged by the use this EALM and this allowed familiarity of clinical handling EAL. However, this study was limited by the small number of students exposed to this new method. Further prospective study is required by increasing the sample size to provide more significant results.
format Article
author Berhanuddin, Muhamad Asyraf
Mohamad, Nurul Fasiha
Ayoub, Afzan Adilah
Kamaruzaman, Marlena
Baharuddin, Izyan Hazwani
Ismail, Ikmal Hisham
author_facet Berhanuddin, Muhamad Asyraf
Mohamad, Nurul Fasiha
Ayoub, Afzan Adilah
Kamaruzaman, Marlena
Baharuddin, Izyan Hazwani
Ismail, Ikmal Hisham
author_sort Berhanuddin, Muhamad Asyraf
title Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.]
title_short Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.]
title_full Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.]
title_fullStr Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.]
title_full_unstemmed Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.]
title_sort model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a uitm experience pilot study / muhamad asyraf berhanuddin ... [et al.]
publisher Faculty of Dentistry, Universiti Teknologi MARA
publishDate 2021
url https://ir.uitm.edu.my/id/eprint/69429/1/69429.pdf
https://ir.uitm.edu.my/id/eprint/69429/
https://doi.org/10.24191/cos.v8i0.17483
_version_ 1748706014394318848
score 13.211869