Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.]
Background: Electronic Apex Locators (EAL) has been increasingly used to facilitate working length determination in endodontics. This instrument is becoming more important to be used in addition to radiographs. A steep learning curve has existed between EAL use in the clinical, from the pre-clinical...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Dentistry, Universiti Teknologi MARA
2021
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/69429/1/69429.pdf https://ir.uitm.edu.my/id/eprint/69429/ https://doi.org/10.24191/cos.v8i0.17483 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.69429 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.694292022-10-31T06:40:19Z https://ir.uitm.edu.my/id/eprint/69429/ Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.] Berhanuddin, Muhamad Asyraf Mohamad, Nurul Fasiha Ayoub, Afzan Adilah Kamaruzaman, Marlena Baharuddin, Izyan Hazwani Ismail, Ikmal Hisham Dental health education Prosthetic dentistry. Prosthodontics Background: Electronic Apex Locators (EAL) has been increasingly used to facilitate working length determination in endodontics. This instrument is becoming more important to be used in addition to radiographs. A steep learning curve has existed between EAL use in the clinical, from the pre-clinical settings. Objectives: To fabricate a model that will facilitate dental students to use Electronic Apex Locator (EAL) in the dental simulation clinic and to conduct a questionnaire-based survey to investigate Electronic Apex Locator Model (EALM) effectiveness. Materials and Methods: Construction of model master jaw, EALM, using materials available in the prosthetic laboratory. The model can be mounted on the phantom head which when connected to an EAL will simulate its clinical use. A validated questionnaire was distributed to a group of n=10 pre-clinical students before and after demonstration conducted at the simulation clinic. Results: A prototype EALM was successfully fabricated at Universiti Teknologi MARA Dental Prosthetic Laboratory. with features incorporating conductive-media-chamber, with attached anatomically-correct fabricated model teeth. The teeth were constructed incorporating continuous access cavity, root canal, through to a patent apex. When attached to the jaw model, the electrical circuit was connected allowing EAL to function. Conclusion: EALM can be conveniently constructed at the Dental Prosthetic Laboratory by using materials readily available here. Furthermore, a steep learning curve exist between pre-clinical and clinical studies was bridged by the use this EALM and this allowed familiarity of clinical handling EAL. However, this study was limited by the small number of students exposed to this new method. Further prospective study is required by increasing the sample size to provide more significant results. Faculty of Dentistry, Universiti Teknologi MARA 2021 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/69429/1/69429.pdf Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.]. (2021) Compendium of Oral Science (CORALS), 8. pp. 55-68. ISSN 2489-1102; 2637-0611 https://doi.org/10.24191/cos.v8i0.17483 |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Dental health education Prosthetic dentistry. Prosthodontics |
spellingShingle |
Dental health education Prosthetic dentistry. Prosthodontics Berhanuddin, Muhamad Asyraf Mohamad, Nurul Fasiha Ayoub, Afzan Adilah Kamaruzaman, Marlena Baharuddin, Izyan Hazwani Ismail, Ikmal Hisham Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.] |
description |
Background: Electronic Apex Locators (EAL) has been increasingly used to facilitate working length determination in endodontics. This instrument is becoming more important to be used in addition to radiographs. A steep learning curve has existed between EAL use in the clinical, from the pre-clinical settings. Objectives: To fabricate a model that will facilitate dental students to use Electronic Apex Locator (EAL) in the dental simulation clinic and to conduct a questionnaire-based survey to investigate Electronic Apex Locator Model (EALM) effectiveness. Materials and Methods: Construction of model master jaw, EALM, using materials available in the prosthetic laboratory. The model can be mounted on the phantom head which when connected to an EAL will simulate its clinical use. A validated questionnaire was distributed to a group of n=10 pre-clinical students before and after demonstration conducted at the simulation clinic. Results: A prototype EALM was successfully fabricated at Universiti Teknologi MARA Dental Prosthetic Laboratory. with features incorporating conductive-media-chamber, with attached anatomically-correct fabricated model teeth. The teeth were constructed incorporating continuous access cavity, root canal, through to a patent apex. When attached to the jaw model, the electrical circuit was connected allowing EAL to function. Conclusion: EALM can be conveniently constructed at the Dental Prosthetic Laboratory by using materials readily available here. Furthermore, a steep learning curve exist between pre-clinical and clinical studies was bridged by the use this EALM and this allowed familiarity of clinical handling EAL. However, this study was limited by the small number of students exposed to this new method. Further prospective study is required by increasing the sample size to provide more significant results. |
format |
Article |
author |
Berhanuddin, Muhamad Asyraf Mohamad, Nurul Fasiha Ayoub, Afzan Adilah Kamaruzaman, Marlena Baharuddin, Izyan Hazwani Ismail, Ikmal Hisham |
author_facet |
Berhanuddin, Muhamad Asyraf Mohamad, Nurul Fasiha Ayoub, Afzan Adilah Kamaruzaman, Marlena Baharuddin, Izyan Hazwani Ismail, Ikmal Hisham |
author_sort |
Berhanuddin, Muhamad Asyraf |
title |
Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.] |
title_short |
Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.] |
title_full |
Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.] |
title_fullStr |
Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.] |
title_full_unstemmed |
Model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a UiTM experience pilot study / Muhamad Asyraf Berhanuddin ... [et al.] |
title_sort |
model to aid teaching of electronic apex locator use for endodontics in dental pre-clinical training – a uitm experience pilot study / muhamad asyraf berhanuddin ... [et al.] |
publisher |
Faculty of Dentistry, Universiti Teknologi MARA |
publishDate |
2021 |
url |
https://ir.uitm.edu.my/id/eprint/69429/1/69429.pdf https://ir.uitm.edu.my/id/eprint/69429/ https://doi.org/10.24191/cos.v8i0.17483 |
_version_ |
1748706014394318848 |
score |
13.211869 |