Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli
Our project aims is to do exergy analysis, which concerned about the useful work potential of the energy. With the development of efficient use of energy resources, over the last dozen years, exergy principle has been used to enhance the understanding of thermal processes and to allow sources of ine...
Saved in:
Main Authors: | , |
---|---|
Format: | Student Project |
Language: | English |
Published: |
2001
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/68612/1/68612.pdf https://ir.uitm.edu.my/id/eprint/68612/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.68612 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.686122022-10-19T07:13:24Z https://ir.uitm.edu.my/id/eprint/68612/ Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli Rumpa, Affandi Keli, Dominic Christopher Power plants Our project aims is to do exergy analysis, which concerned about the useful work potential of the energy. With the development of efficient use of energy resources, over the last dozen years, exergy principle has been used to enhance the understanding of thermal processes and to allow sources of inefficiency to be quantified. It is well known that the exergy balance can be used to determine the location, type, and true magnitude of exergy loss (or destruction), and thus can play an important role in developing strategies and in providing guidelines for more effective use of energy in the existing power plants. But a more important issue for improving the existing system is the origin of the exergy loss, and hence a clearer picture, instead of only the magnitude of exergy loss in each section, is required. Referring to Sultan Salahuddin Abdul Aziz Power Station, Kapar uses the supercritical steam at 192 bar and 538.2°C including reheating, regenerating and condensing steam turbine. The steam turbine consist of high, intermediate and low-pressure turbine and there are eight stages extraction from the steam turbine provides steam for the regenerative feeding water heater. The extraction of steam from state of intermediate pressure also adds steam for the driving of boiler feedwater pump turbine. 2001 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/68612/1/68612.pdf Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli. (2001) [Student Project] (Unpublished) |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Power plants |
spellingShingle |
Power plants Rumpa, Affandi Keli, Dominic Christopher Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli |
description |
Our project aims is to do exergy analysis, which concerned about the useful work potential of the energy. With the development of efficient use of energy resources, over the last dozen years, exergy principle has been used to enhance the understanding of thermal processes and to allow sources of inefficiency to be quantified. It is well known that the exergy balance can be used to determine the location, type, and true magnitude of exergy loss (or destruction), and thus can play an important role in developing strategies and in providing guidelines for more effective use of energy in the existing power plants. But a more important issue for improving the existing system is the origin of the exergy loss, and hence a clearer picture, instead of only the magnitude of exergy loss in each section, is required. Referring to Sultan Salahuddin Abdul Aziz Power Station, Kapar uses the supercritical steam at 192 bar and 538.2°C including reheating, regenerating and condensing steam turbine. The steam turbine consist of high, intermediate and low-pressure turbine and there are eight stages extraction from the steam turbine provides steam for the regenerative feeding water heater. The extraction of steam from state of intermediate pressure also adds steam for the driving of boiler feedwater pump turbine. |
format |
Student Project |
author |
Rumpa, Affandi Keli, Dominic Christopher |
author_facet |
Rumpa, Affandi Keli, Dominic Christopher |
author_sort |
Rumpa, Affandi |
title |
Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli |
title_short |
Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli |
title_full |
Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli |
title_fullStr |
Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli |
title_full_unstemmed |
Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli |
title_sort |
exergy evaluation of supercritical steam power plant generation / affandi rumpa and dominic christopher keli |
publishDate |
2001 |
url |
https://ir.uitm.edu.my/id/eprint/68612/1/68612.pdf https://ir.uitm.edu.my/id/eprint/68612/ |
_version_ |
1748183925184790528 |
score |
13.209306 |