Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli

Our project aims is to do exergy analysis, which concerned about the useful work potential of the energy. With the development of efficient use of energy resources, over the last dozen years, exergy principle has been used to enhance the understanding of thermal processes and to allow sources of ine...

Full description

Saved in:
Bibliographic Details
Main Authors: Rumpa, Affandi, Keli, Dominic Christopher
Format: Student Project
Language:English
Published: 2001
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/68612/1/68612.pdf
https://ir.uitm.edu.my/id/eprint/68612/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.68612
record_format eprints
spelling my.uitm.ir.686122022-10-19T07:13:24Z https://ir.uitm.edu.my/id/eprint/68612/ Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli Rumpa, Affandi Keli, Dominic Christopher Power plants Our project aims is to do exergy analysis, which concerned about the useful work potential of the energy. With the development of efficient use of energy resources, over the last dozen years, exergy principle has been used to enhance the understanding of thermal processes and to allow sources of inefficiency to be quantified. It is well known that the exergy balance can be used to determine the location, type, and true magnitude of exergy loss (or destruction), and thus can play an important role in developing strategies and in providing guidelines for more effective use of energy in the existing power plants. But a more important issue for improving the existing system is the origin of the exergy loss, and hence a clearer picture, instead of only the magnitude of exergy loss in each section, is required. Referring to Sultan Salahuddin Abdul Aziz Power Station, Kapar uses the supercritical steam at 192 bar and 538.2°C including reheating, regenerating and condensing steam turbine. The steam turbine consist of high, intermediate and low-pressure turbine and there are eight stages extraction from the steam turbine provides steam for the regenerative feeding water heater. The extraction of steam from state of intermediate pressure also adds steam for the driving of boiler feedwater pump turbine. 2001 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/68612/1/68612.pdf Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli. (2001) [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Power plants
spellingShingle Power plants
Rumpa, Affandi
Keli, Dominic Christopher
Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli
description Our project aims is to do exergy analysis, which concerned about the useful work potential of the energy. With the development of efficient use of energy resources, over the last dozen years, exergy principle has been used to enhance the understanding of thermal processes and to allow sources of inefficiency to be quantified. It is well known that the exergy balance can be used to determine the location, type, and true magnitude of exergy loss (or destruction), and thus can play an important role in developing strategies and in providing guidelines for more effective use of energy in the existing power plants. But a more important issue for improving the existing system is the origin of the exergy loss, and hence a clearer picture, instead of only the magnitude of exergy loss in each section, is required. Referring to Sultan Salahuddin Abdul Aziz Power Station, Kapar uses the supercritical steam at 192 bar and 538.2°C including reheating, regenerating and condensing steam turbine. The steam turbine consist of high, intermediate and low-pressure turbine and there are eight stages extraction from the steam turbine provides steam for the regenerative feeding water heater. The extraction of steam from state of intermediate pressure also adds steam for the driving of boiler feedwater pump turbine.
format Student Project
author Rumpa, Affandi
Keli, Dominic Christopher
author_facet Rumpa, Affandi
Keli, Dominic Christopher
author_sort Rumpa, Affandi
title Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli
title_short Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli
title_full Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli
title_fullStr Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli
title_full_unstemmed Exergy evaluation of supercritical steam power plant generation / Affandi Rumpa and Dominic Christopher Keli
title_sort exergy evaluation of supercritical steam power plant generation / affandi rumpa and dominic christopher keli
publishDate 2001
url https://ir.uitm.edu.my/id/eprint/68612/1/68612.pdf
https://ir.uitm.edu.my/id/eprint/68612/
_version_ 1748183925184790528
score 13.209306