Structural performance of hybrid mengkulang glulam concrete beam / Shuhada Mohd Yusoff

Engineered wood products, such as glued laminated timber (glulam), are designed to decrease the weaknesses of natural wood, such as knots and non-uniform strength, and so increase stiffness and weight carrying capability. One way for increasing the load carrying capacity and performance of glulam st...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Yusoff, Shuhada
Format: Thesis
Language:English
Published: 2021
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/60613/1/60613.pdf
https://ir.uitm.edu.my/id/eprint/60613/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.60613
record_format eprints
spelling my.uitm.ir.606132022-05-31T02:43:41Z https://ir.uitm.edu.my/id/eprint/60613/ Structural performance of hybrid mengkulang glulam concrete beam / Shuhada Mohd Yusoff Mohd Yusoff, Shuhada Timber. Wood Concrete Engineered wood products, such as glued laminated timber (glulam), are designed to decrease the weaknesses of natural wood, such as knots and non-uniform strength, and so increase stiffness and weight carrying capability. One way for increasing the load carrying capacity and performance of glulam structures is to use glulam-composite constructions. Several elements must be considered, including the stiffness of the bonding lines and the presence of flaws in the wood. The materials tests were carried out to explore the materials properties of glulam, such as moisture content, shear block, and delamination test, while concrete qualities were tested for slump and compression tests. In this study, the constraints and benefits of combining concrete with glulam have been addressed. Mengkulang beam and hybrid Mengkulang glulam with concrete (HMGC) structural sizes have been designated as RC, MC, HMGC A and HMGC B, respectively. Mengkulang glulam beam’s modulus of rupture (MOR) and modulus of elasticity (MOE) was found to be 66.67 N/mm2 and 14,565.23 N/mm2, respectively. The load-carrying capacity of MG was 119.48 kN for this study is three times higher than the RC beam of 40.48 kN and lower than HMGC A and HMGC B by 53.51% and 46.24%, respectively. Both HMGC A and B did not contributed to the bending strength of the MG beam however contributed to double the displacement prior to fracture. Both HMGCs failed due to MG layers splits in the tension zone on weaker zone (finger-joint area) and concrete cracks in the compression zone. Screws acting as the shear-stud between two hybrid materials failed to keep the two materials intact, resulting in non-composite behaviour. 2021-12 Thesis NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/60613/1/60613.pdf Structural performance of hybrid mengkulang glulam concrete beam / Shuhada Mohd Yusoff. (2021) Masters thesis, thesis, Universiti Teknologi MARA.
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Timber. Wood
Concrete
spellingShingle Timber. Wood
Concrete
Mohd Yusoff, Shuhada
Structural performance of hybrid mengkulang glulam concrete beam / Shuhada Mohd Yusoff
description Engineered wood products, such as glued laminated timber (glulam), are designed to decrease the weaknesses of natural wood, such as knots and non-uniform strength, and so increase stiffness and weight carrying capability. One way for increasing the load carrying capacity and performance of glulam structures is to use glulam-composite constructions. Several elements must be considered, including the stiffness of the bonding lines and the presence of flaws in the wood. The materials tests were carried out to explore the materials properties of glulam, such as moisture content, shear block, and delamination test, while concrete qualities were tested for slump and compression tests. In this study, the constraints and benefits of combining concrete with glulam have been addressed. Mengkulang beam and hybrid Mengkulang glulam with concrete (HMGC) structural sizes have been designated as RC, MC, HMGC A and HMGC B, respectively. Mengkulang glulam beam’s modulus of rupture (MOR) and modulus of elasticity (MOE) was found to be 66.67 N/mm2 and 14,565.23 N/mm2, respectively. The load-carrying capacity of MG was 119.48 kN for this study is three times higher than the RC beam of 40.48 kN and lower than HMGC A and HMGC B by 53.51% and 46.24%, respectively. Both HMGC A and B did not contributed to the bending strength of the MG beam however contributed to double the displacement prior to fracture. Both HMGCs failed due to MG layers splits in the tension zone on weaker zone (finger-joint area) and concrete cracks in the compression zone. Screws acting as the shear-stud between two hybrid materials failed to keep the two materials intact, resulting in non-composite behaviour.
format Thesis
author Mohd Yusoff, Shuhada
author_facet Mohd Yusoff, Shuhada
author_sort Mohd Yusoff, Shuhada
title Structural performance of hybrid mengkulang glulam concrete beam / Shuhada Mohd Yusoff
title_short Structural performance of hybrid mengkulang glulam concrete beam / Shuhada Mohd Yusoff
title_full Structural performance of hybrid mengkulang glulam concrete beam / Shuhada Mohd Yusoff
title_fullStr Structural performance of hybrid mengkulang glulam concrete beam / Shuhada Mohd Yusoff
title_full_unstemmed Structural performance of hybrid mengkulang glulam concrete beam / Shuhada Mohd Yusoff
title_sort structural performance of hybrid mengkulang glulam concrete beam / shuhada mohd yusoff
publishDate 2021
url https://ir.uitm.edu.my/id/eprint/60613/1/60613.pdf
https://ir.uitm.edu.my/id/eprint/60613/
_version_ 1735389644075302912
score 13.222552