System performance and detectable faults of a 10-year old 1.1 kWp GCPV system in Malaysia / Nurmalessa Muhammad ... [et al.].
This paper presents the findings of a study conducted to evaluate the performance and to identify faults of a 10-year old 1.1kW grid-connected photovoltaic (GCPV) system installed at Green Energy Research Center (GERC), Universiti Teknologi MARA (UiTM), Shah Alam. The system performance was evaluate...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2017
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/60296/1/60296.pdf https://ir.uitm.edu.my/id/eprint/60296/ https://scilett-fsg.uitm.edu.my/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uitm.ir.60296 |
---|---|
record_format |
eprints |
spelling |
my.uitm.ir.602962022-06-14T07:55:35Z https://ir.uitm.edu.my/id/eprint/60296/ System performance and detectable faults of a 10-year old 1.1 kWp GCPV system in Malaysia / Nurmalessa Muhammad ... [et al.]. Muhammad, Nurmalessa Zakaria, Nor Zaini Shaari, Sulaiman Omar, Ahmad Maliki Electricity This paper presents the findings of a study conducted to evaluate the performance and to identify faults of a 10-year old 1.1kW grid-connected photovoltaic (GCPV) system installed at Green Energy Research Center (GERC), Universiti Teknologi MARA (UiTM), Shah Alam. The system performance was evaluated by comparing the real operating field data with the data declared by the manufacturer. Eight performance indicators were used, which are: reference yield, array yield, final yield, capture losses, system losses, performance ratio, PV array efficiency and total efficiency. The fault detection has used three techniques - which were visual inspection as outlined in the International Energy Agency (IEA) document, thermal imager technique and the I-V curve characteristics. The finding for the system performance evaluation gives a 13.2% difference between the real operating field data and the declared manufacturer data. Among the faults detected from the visual inspection are browning and cracks of PV modules. 2017-06 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/60296/1/60296.pdf System performance and detectable faults of a 10-year old 1.1 kWp GCPV system in Malaysia / Nurmalessa Muhammad ... [et al.]. (2017) Science Letters (ScL), 11 (1): 3. pp. 10-17. ISSN (eISSN): 2682-8626 https://scilett-fsg.uitm.edu.my/ |
institution |
Universiti Teknologi Mara |
building |
Tun Abdul Razak Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Mara |
content_source |
UiTM Institutional Repository |
url_provider |
http://ir.uitm.edu.my/ |
language |
English |
topic |
Electricity |
spellingShingle |
Electricity Muhammad, Nurmalessa Zakaria, Nor Zaini Shaari, Sulaiman Omar, Ahmad Maliki System performance and detectable faults of a 10-year old 1.1 kWp GCPV system in Malaysia / Nurmalessa Muhammad ... [et al.]. |
description |
This paper presents the findings of a study conducted to evaluate the performance and to identify faults of a 10-year old 1.1kW grid-connected photovoltaic (GCPV) system installed at Green Energy Research Center (GERC), Universiti Teknologi MARA (UiTM), Shah Alam. The system performance was evaluated by comparing the real operating field data with the data declared by the manufacturer. Eight performance indicators were used, which are: reference yield, array yield, final yield, capture losses, system losses, performance ratio, PV array efficiency and total efficiency. The fault detection has used three techniques - which were visual inspection as outlined in the International Energy Agency (IEA) document, thermal imager technique and the I-V curve characteristics. The finding for the system performance evaluation gives a 13.2% difference between the real operating field data and the declared manufacturer data. Among the
faults detected from the visual inspection are browning and cracks of PV modules. |
format |
Article |
author |
Muhammad, Nurmalessa Zakaria, Nor Zaini Shaari, Sulaiman Omar, Ahmad Maliki |
author_facet |
Muhammad, Nurmalessa Zakaria, Nor Zaini Shaari, Sulaiman Omar, Ahmad Maliki |
author_sort |
Muhammad, Nurmalessa |
title |
System performance and detectable faults of a 10-year old 1.1 kWp GCPV system in Malaysia / Nurmalessa Muhammad ... [et al.]. |
title_short |
System performance and detectable faults of a 10-year old 1.1 kWp GCPV system in Malaysia / Nurmalessa Muhammad ... [et al.]. |
title_full |
System performance and detectable faults of a 10-year old 1.1 kWp GCPV system in Malaysia / Nurmalessa Muhammad ... [et al.]. |
title_fullStr |
System performance and detectable faults of a 10-year old 1.1 kWp GCPV system in Malaysia / Nurmalessa Muhammad ... [et al.]. |
title_full_unstemmed |
System performance and detectable faults of a 10-year old 1.1 kWp GCPV system in Malaysia / Nurmalessa Muhammad ... [et al.]. |
title_sort |
system performance and detectable faults of a 10-year old 1.1 kwp gcpv system in malaysia / nurmalessa muhammad ... [et al.]. |
publishDate |
2017 |
url |
https://ir.uitm.edu.my/id/eprint/60296/1/60296.pdf https://ir.uitm.edu.my/id/eprint/60296/ https://scilett-fsg.uitm.edu.my/ |
_version_ |
1736837299230998528 |
score |
13.214268 |