Comparison between High Performance Liquid Chromatography and Capillary Electrophoresis in detecting Haemoglobin Constant Spring / Muhammad Ikmal Mohd Nizar ... [et al.]

Two popular methods - High Performance Liquid Chromatography (HPLC) and Capillary Electrophoresis (CE) have been compared for diagnosis of Haemoglobin Constant Spring (HbCS). The performance of the methods was evaluated in terms of sensitivity, specificity, positive predictive value (PPV) and negati...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohamed, Emida, Mohd Nizar, Muhammad Ikmal, Raja Sabudin, Raja Zahratul Azma, Camalxaman, Siti Nazrina, Sham Rambely, Azlin, Haron, Norhisham
Format: Article
Language:English
Published: Faculty of Health Sciences, Universiti Teknologi MARA 2019
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/54674/1/54674.pdf
https://ir.uitm.edu.my/id/eprint/54674/
http://healthscopefsk.com/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.54674
record_format eprints
spelling my.uitm.ir.546742021-12-22T03:53:38Z https://ir.uitm.edu.my/id/eprint/54674/ Comparison between High Performance Liquid Chromatography and Capillary Electrophoresis in detecting Haemoglobin Constant Spring / Muhammad Ikmal Mohd Nizar ... [et al.] Mohamed, Emida Mohd Nizar, Muhammad Ikmal Raja Sabudin, Raja Zahratul Azma Camalxaman, Siti Nazrina Sham Rambely, Azlin Haron, Norhisham Analytical chemistry Electrophoresis Two popular methods - High Performance Liquid Chromatography (HPLC) and Capillary Electrophoresis (CE) have been compared for diagnosis of Haemoglobin Constant Spring (HbCS). The performance of the methods was evaluated in terms of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). A total of thirty-two results were collected at HUKM which consisted of results derived from HPLC, CE and ARMS-PCR from December 2012 until December 2017. Results obtained showed CE demonstrated higher sensitivity, specificity, PPV and NPV compared to HPLC in the detection of HbCS. Faculty of Health Sciences, Universiti Teknologi MARA 2019-06 Article PeerReviewed text en https://ir.uitm.edu.my/id/eprint/54674/1/54674.pdf ID54674 Mohamed, Emida and Mohd Nizar, Muhammad Ikmal and Raja Sabudin, Raja Zahratul Azma and Camalxaman, Siti Nazrina and Sham Rambely, Azlin and Haron, Norhisham (2019) Comparison between High Performance Liquid Chromatography and Capillary Electrophoresis in detecting Haemoglobin Constant Spring / Muhammad Ikmal Mohd Nizar ... [et al.]. Health Scope, 1. pp. 76-78. ISSN 2735-0649 http://healthscopefsk.com/
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Analytical chemistry
Electrophoresis
spellingShingle Analytical chemistry
Electrophoresis
Mohamed, Emida
Mohd Nizar, Muhammad Ikmal
Raja Sabudin, Raja Zahratul Azma
Camalxaman, Siti Nazrina
Sham Rambely, Azlin
Haron, Norhisham
Comparison between High Performance Liquid Chromatography and Capillary Electrophoresis in detecting Haemoglobin Constant Spring / Muhammad Ikmal Mohd Nizar ... [et al.]
description Two popular methods - High Performance Liquid Chromatography (HPLC) and Capillary Electrophoresis (CE) have been compared for diagnosis of Haemoglobin Constant Spring (HbCS). The performance of the methods was evaluated in terms of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). A total of thirty-two results were collected at HUKM which consisted of results derived from HPLC, CE and ARMS-PCR from December 2012 until December 2017. Results obtained showed CE demonstrated higher sensitivity, specificity, PPV and NPV compared to HPLC in the detection of HbCS.
format Article
author Mohamed, Emida
Mohd Nizar, Muhammad Ikmal
Raja Sabudin, Raja Zahratul Azma
Camalxaman, Siti Nazrina
Sham Rambely, Azlin
Haron, Norhisham
author_facet Mohamed, Emida
Mohd Nizar, Muhammad Ikmal
Raja Sabudin, Raja Zahratul Azma
Camalxaman, Siti Nazrina
Sham Rambely, Azlin
Haron, Norhisham
author_sort Mohamed, Emida
title Comparison between High Performance Liquid Chromatography and Capillary Electrophoresis in detecting Haemoglobin Constant Spring / Muhammad Ikmal Mohd Nizar ... [et al.]
title_short Comparison between High Performance Liquid Chromatography and Capillary Electrophoresis in detecting Haemoglobin Constant Spring / Muhammad Ikmal Mohd Nizar ... [et al.]
title_full Comparison between High Performance Liquid Chromatography and Capillary Electrophoresis in detecting Haemoglobin Constant Spring / Muhammad Ikmal Mohd Nizar ... [et al.]
title_fullStr Comparison between High Performance Liquid Chromatography and Capillary Electrophoresis in detecting Haemoglobin Constant Spring / Muhammad Ikmal Mohd Nizar ... [et al.]
title_full_unstemmed Comparison between High Performance Liquid Chromatography and Capillary Electrophoresis in detecting Haemoglobin Constant Spring / Muhammad Ikmal Mohd Nizar ... [et al.]
title_sort comparison between high performance liquid chromatography and capillary electrophoresis in detecting haemoglobin constant spring / muhammad ikmal mohd nizar ... [et al.]
publisher Faculty of Health Sciences, Universiti Teknologi MARA
publishDate 2019
url https://ir.uitm.edu.my/id/eprint/54674/1/54674.pdf
https://ir.uitm.edu.my/id/eprint/54674/
http://healthscopefsk.com/
_version_ 1720439847977484288
score 13.18916