Air quality of supplied air in a high-rise commercial / Wan Nor 'Afifah Wan Mohammad Nor

A cross-sectional study was conducted in a high-rise commercial building from February 2014 to April 2014. The main objective of the study was to determine the Air Quality supplied air in a high rise commercial building based on these parameters: Temperature, Relative Humidity, Carbon Dioxide, Forma...

Full description

Saved in:
Bibliographic Details
Main Author: Wan Mohammad Nor, Wan Nor 'Afifah
Format: Student Project
Language:English
Published: 2014
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/53442/1/53442.PDF
https://ir.uitm.edu.my/id/eprint/53442/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.53442
record_format eprints
spelling my.uitm.ir.534422021-11-18T01:34:49Z https://ir.uitm.edu.my/id/eprint/53442/ Air quality of supplied air in a high-rise commercial / Wan Nor 'Afifah Wan Mohammad Nor Wan Mohammad Nor, Wan Nor 'Afifah Public health. Hygiene. Preventive Medicine Environmental health. Including sewage disposal, air pollution, nuisances, water supply Environmental pollution Indoor air pollution. Including indoor air quality A cross-sectional study was conducted in a high-rise commercial building from February 2014 to April 2014. The main objective of the study was to determine the Air Quality supplied air in a high rise commercial building based on these parameters: Temperature, Relative Humidity, Carbon Dioxide, Formaldehyde, Carbon Monoxide and VOC. All floors were sampled at the AHU, directly before the air is released into the occupants' floors. All the readings measured were below the legal requirement of the Industrial Code of Practice on Indoor Air Quality except for formaldehyde. ANOVA statistical test showed significance of Relative Humidity between Middle Segment and Upper Segment (p=0.002); Carbon Dioxide between Lower Segment and Upper Segment (p=0.023); Formaldehyde between Lower Segment and Middle Segment (p=0.023), Lower Segment and Upper Segment (p=0.000). Through focus group discussion it was found that different floors within one segment also had an impact on the thermal comfort. When the occupants' floor is further from the main AHU, the occupants tend to feel warmer compared to those who are nearer the main AHUs. In conclusion, the air quality of supplied air is influenced by many factors. One of the main factors is the distance between the main AHUs and the tenants' floor as there is the loss factor that occurs when the supply duct carries the fresh air to the tenants' floors. 2014-07 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/53442/1/53442.PDF ID53442 Wan Mohammad Nor, Wan Nor 'Afifah (2014) Air quality of supplied air in a high-rise commercial / Wan Nor 'Afifah Wan Mohammad Nor. [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Public health. Hygiene. Preventive Medicine
Environmental health. Including sewage disposal, air pollution, nuisances, water supply
Environmental pollution
Indoor air pollution. Including indoor air quality
spellingShingle Public health. Hygiene. Preventive Medicine
Environmental health. Including sewage disposal, air pollution, nuisances, water supply
Environmental pollution
Indoor air pollution. Including indoor air quality
Wan Mohammad Nor, Wan Nor 'Afifah
Air quality of supplied air in a high-rise commercial / Wan Nor 'Afifah Wan Mohammad Nor
description A cross-sectional study was conducted in a high-rise commercial building from February 2014 to April 2014. The main objective of the study was to determine the Air Quality supplied air in a high rise commercial building based on these parameters: Temperature, Relative Humidity, Carbon Dioxide, Formaldehyde, Carbon Monoxide and VOC. All floors were sampled at the AHU, directly before the air is released into the occupants' floors. All the readings measured were below the legal requirement of the Industrial Code of Practice on Indoor Air Quality except for formaldehyde. ANOVA statistical test showed significance of Relative Humidity between Middle Segment and Upper Segment (p=0.002); Carbon Dioxide between Lower Segment and Upper Segment (p=0.023); Formaldehyde between Lower Segment and Middle Segment (p=0.023), Lower Segment and Upper Segment (p=0.000). Through focus group discussion it was found that different floors within one segment also had an impact on the thermal comfort. When the occupants' floor is further from the main AHU, the occupants tend to feel warmer compared to those who are nearer the main AHUs. In conclusion, the air quality of supplied air is influenced by many factors. One of the main factors is the distance between the main AHUs and the tenants' floor as there is the loss factor that occurs when the supply duct carries the fresh air to the tenants' floors.
format Student Project
author Wan Mohammad Nor, Wan Nor 'Afifah
author_facet Wan Mohammad Nor, Wan Nor 'Afifah
author_sort Wan Mohammad Nor, Wan Nor 'Afifah
title Air quality of supplied air in a high-rise commercial / Wan Nor 'Afifah Wan Mohammad Nor
title_short Air quality of supplied air in a high-rise commercial / Wan Nor 'Afifah Wan Mohammad Nor
title_full Air quality of supplied air in a high-rise commercial / Wan Nor 'Afifah Wan Mohammad Nor
title_fullStr Air quality of supplied air in a high-rise commercial / Wan Nor 'Afifah Wan Mohammad Nor
title_full_unstemmed Air quality of supplied air in a high-rise commercial / Wan Nor 'Afifah Wan Mohammad Nor
title_sort air quality of supplied air in a high-rise commercial / wan nor 'afifah wan mohammad nor
publishDate 2014
url https://ir.uitm.edu.my/id/eprint/53442/1/53442.PDF
https://ir.uitm.edu.my/id/eprint/53442/
_version_ 1717097251677929472
score 13.160551