Indoor air quality in UiTM Puncak Alam residential building / Mohd Khairullazwan Khairullanuar

The study was conducted to evaluate Indoor Air Quality (IAQ) in UiTM's Hostel rooms. The study also compared IAQ between Block Angsana (old hostel building) and Block Casuarina (new hostel building). One hundred rooms (n=100) are selected for parameter measuring. Fifty...

Full description

Saved in:
Bibliographic Details
Main Author: Khairullanuar, Mohd Khairullazwan
Format: Student Project
Language:English
Published: 2014
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/52591/1/52591.PDF
https://ir.uitm.edu.my/id/eprint/52591/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.52591
record_format eprints
spelling my.uitm.ir.525912021-10-27T08:21:14Z https://ir.uitm.edu.my/id/eprint/52591/ Indoor air quality in UiTM Puncak Alam residential building / Mohd Khairullazwan Khairullanuar Khairullanuar, Mohd Khairullazwan Dormitories. Residence halls. Student housing Special types of environment. Including soil pollution, air pollution, noise pollution Indoor air pollution. Including indoor air quality The study was conducted to evaluate Indoor Air Quality (IAQ) in UiTM's Hostel rooms. The study also compared IAQ between Block Angsana (old hostel building) and Block Casuarina (new hostel building). One hundred rooms (n=100) are selected for parameter measuring. Fifty rooms were Angsana hostel (n=50) while another fifty rooms were collected from Casuarina rooms (n=50). Each room was measured for five parameters include Total Volatile Organic Compound (TVOC), Carbon Dioxide, room temperature, air velocity, and relative humidity. In addition, comparing with Industrial Code of Practice for Indoor Air Quality 2011, there were no violation against all parameter measured except for room temperature and relative humidity. The result showed that all rooms (n=100) are not compliance for room temperature within the standard guidelines while sixteen rooms (n=16) are not compliance for relative humidity standard guidelines. The study also found that there were significant different (p<0.05) between old building and new building for air velocity (p=0.000), TVOC (p=0.000) and CO2 (p=0.003) concentration Casuarina (new building) had higher concentration. However there was no significant difference (p»0.05) between the new building and the old building for relative humidity and temperature. Statistical analysis for correlation between TVOC and CO2 showed fair significant thus proving that if CO2 increased TVOC also have tend to be increased. As the room temperature is high, it is not good in terms of thermal comfort thus few recommendations had done to control temperature such as installed overhang, tree planting, and promoting good behavior. Besides that for TVOC emission control and relative humidity reduction, isolation for laundry rooms are suggested, maintenance check on mechanical ventilation and health promotion towards awareness of chemical compounds in households. In addition, high temperature and high humidity caused mold growth in building. Mold growth can give adverse health effect to human such as allergic and respiratory problem. Thus, the authorities must responsible in preventing mold growth in building. It is suggested that anti mold paint and material should be used in building and also controlling level of temperature and humidity. 2014-07 Student Project NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/52591/1/52591.PDF ID52591 Khairullanuar, Mohd Khairullazwan (2014) Indoor air quality in UiTM Puncak Alam residential building / Mohd Khairullazwan Khairullanuar. [Student Project] (Unpublished)
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Dormitories. Residence halls. Student housing
Special types of environment. Including soil pollution, air pollution, noise pollution
Indoor air pollution. Including indoor air quality
spellingShingle Dormitories. Residence halls. Student housing
Special types of environment. Including soil pollution, air pollution, noise pollution
Indoor air pollution. Including indoor air quality
Khairullanuar, Mohd Khairullazwan
Indoor air quality in UiTM Puncak Alam residential building / Mohd Khairullazwan Khairullanuar
description The study was conducted to evaluate Indoor Air Quality (IAQ) in UiTM's Hostel rooms. The study also compared IAQ between Block Angsana (old hostel building) and Block Casuarina (new hostel building). One hundred rooms (n=100) are selected for parameter measuring. Fifty rooms were Angsana hostel (n=50) while another fifty rooms were collected from Casuarina rooms (n=50). Each room was measured for five parameters include Total Volatile Organic Compound (TVOC), Carbon Dioxide, room temperature, air velocity, and relative humidity. In addition, comparing with Industrial Code of Practice for Indoor Air Quality 2011, there were no violation against all parameter measured except for room temperature and relative humidity. The result showed that all rooms (n=100) are not compliance for room temperature within the standard guidelines while sixteen rooms (n=16) are not compliance for relative humidity standard guidelines. The study also found that there were significant different (p<0.05) between old building and new building for air velocity (p=0.000), TVOC (p=0.000) and CO2 (p=0.003) concentration Casuarina (new building) had higher concentration. However there was no significant difference (p»0.05) between the new building and the old building for relative humidity and temperature. Statistical analysis for correlation between TVOC and CO2 showed fair significant thus proving that if CO2 increased TVOC also have tend to be increased. As the room temperature is high, it is not good in terms of thermal comfort thus few recommendations had done to control temperature such as installed overhang, tree planting, and promoting good behavior. Besides that for TVOC emission control and relative humidity reduction, isolation for laundry rooms are suggested, maintenance check on mechanical ventilation and health promotion towards awareness of chemical compounds in households. In addition, high temperature and high humidity caused mold growth in building. Mold growth can give adverse health effect to human such as allergic and respiratory problem. Thus, the authorities must responsible in preventing mold growth in building. It is suggested that anti mold paint and material should be used in building and also controlling level of temperature and humidity.
format Student Project
author Khairullanuar, Mohd Khairullazwan
author_facet Khairullanuar, Mohd Khairullazwan
author_sort Khairullanuar, Mohd Khairullazwan
title Indoor air quality in UiTM Puncak Alam residential building / Mohd Khairullazwan Khairullanuar
title_short Indoor air quality in UiTM Puncak Alam residential building / Mohd Khairullazwan Khairullanuar
title_full Indoor air quality in UiTM Puncak Alam residential building / Mohd Khairullazwan Khairullanuar
title_fullStr Indoor air quality in UiTM Puncak Alam residential building / Mohd Khairullazwan Khairullanuar
title_full_unstemmed Indoor air quality in UiTM Puncak Alam residential building / Mohd Khairullazwan Khairullanuar
title_sort indoor air quality in uitm puncak alam residential building / mohd khairullazwan khairullanuar
publishDate 2014
url https://ir.uitm.edu.my/id/eprint/52591/1/52591.PDF
https://ir.uitm.edu.my/id/eprint/52591/
_version_ 1715193430921969664
score 13.15806